Download Miller Electric 500SSX Specifications
Transcript
5-2. Overload Protection a READ SAFETY BLOCKS at start of Sectio n 5 bet or e proceeding. WARNING ~-~ffIj -~ When overheated, thermostat output stops, and cooling fan keeps running. Let fan run for 15 minutes. opens, Start welding. ssblO.1 1/94ST-000 599-H Figure 5-2. Overheating 5-3. Troubleshooting ~IVARNING ELECTRC SHOCK can MOVING PARTS kill. Do not tcuch live electrical parts. Keep away from can caus a injury. moving parts. Turn Off welding power source, and disconnect input power before inspecting, maintaining, or servicing. HOT PARTS Allow can cause severe cooling period before burns. servicing. Troubleshooting to be performed only by qualified persons. swam9.1 2/93 Table 5-1. Welding Trouble No weld output; inoperative. unit Trouble Section Remedy completely -~ Place line disconnect switch in the On position. 3-5B ] Check for open line luse(s), and replace if necessary. Check and reset circuit breakers. Check for proper input connections. Check for proper jumper link positions. Thermostat TP1 opEn. Allow fifteen minutes. a cooling Check push button Power switch obstructions. No weld output; pilot light PL1 on. -~ Clean and tighten period of approximately linkage for restrictions or 3-5B -~ 3-5B -~ 3-5A -~ 5-2 -~ all weld connections. Place Output (Contactor) switch in the On Remote Contactor Control To RC1. -~ -~ position Check remote contactor control switch for proper ohmmeter, and rEplace if necessary. or connect operation with -~ -~ an Have Factory Authorized Service Station/Service Distributor check control board PCi. OM-168 256 Page 14 -~ 3-3 Figure 4-4