Download Miller Electric 500SSX Specifications

Transcript
5-2.
Overload Protection
a
READ SAFETY BLOCKS at start of
Sectio n 5 bet or e proceeding.
WARNING
~-~ffIj
-~
When overheated, thermostat
output stops, and cooling
fan keeps running.
Let fan run for
15 minutes.
opens,
Start
welding.
ssblO.1 1/94ST-000
599-H
Figure 5-2. Overheating
5-3.
Troubleshooting
~IVARNING
ELECTRC SHOCK
can
MOVING PARTS
kill.
Do not tcuch live electrical parts.
Keep
away from
can caus a
injury.
moving parts.
Turn Off
welding power source, and disconnect
input power before inspecting, maintaining, or
servicing.
HOT PARTS
Allow
can cause severe
cooling period
before
burns.
servicing.
Troubleshooting
to be
performed only by qualified
persons.
swam9.1 2/93
Table 5-1.
Welding
Trouble
No weld
output;
inoperative.
unit
Trouble
Section
Remedy
completely
-~
Place line disconnect switch in the On position.
3-5B
]
Check for open line luse(s), and replace if necessary. Check
and reset circuit breakers.
Check for proper
input connections.
Check for proper jumper link positions.
Thermostat TP1 opEn. Allow
fifteen minutes.
a
cooling
Check push button Power switch
obstructions.
No weld output;
pilot light PL1
on.
-~
Clean and
tighten
period of approximately
linkage for restrictions
or
3-5B
-~
3-5B
-~
3-5A
-~
5-2
-~
all weld connections.
Place Output (Contactor) switch in the On
Remote Contactor Control To RC1.
-~
-~
position
Check remote contactor control switch for proper
ohmmeter, and rEplace if necessary.
or
connect
operation
with
-~
-~
an
Have Factory Authorized Service Station/Service Distributor
check control board PCi.
OM-168 256
Page
14
-~
3-3
Figure
4-4