CHAPTER 3 • CONTACT CLOSURE COMMUNICATION
NEMA TS2, 2070 and other advanced traffic cabinet systems usually allow software programming of the detector card channel outputs to traffic phases via a channel-to-phase
mapping grid in the controller menu. Figure 3.9 illustrates how the detector channels 1 to
16 of a NEMA TS-2 rack can be assigned to the standard eight phases using four Click
114 cards. The rack card slots are numbered across the top and the controller’s detection
channels are represented by the gray labels C1–C16.
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
C3
C1
C7
C5
C11
C9
C15
C13
Φ6
Φ1
Φ2
Φ5
Φ8
Φ3
Φ4
Φ7
C4
C2
C8
C6
C12
C10
C16
C14
Φ6
Φ6
Φ2
Φ2
Φ8
Φ8
Φ4
Φ4
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
Figure 3.12 – NEMA TS-2 Type 1 Rack Channel to Traffic Phase Example
In Figure 3.9, four channels are used from each SmartSensor Matrix. In this example,
channel 1 from the first sensor is mapped to traffic phase 1 (left-turn phase on main street).
Channels 2, 3 and 4 from the first sensor are mapped to traffic phase 6. This represents a
case where detections from three through-movement lanes are brought in separately. This
type of lane-by-lane detection can be beneficial in some situations. Wavetronix typically
recommends the use of 4-channel cards because it offers greater flexibility of signaling
contact closures.
Note
With NEMA TS1 and other legacy systems, the programming is often done via a
wiring panel on the side of the controller cabinet. With wired systems, you will need
to verify that the wiring on the detector programming panel provides the proper
mapping from the rack channel outputs to the controller input wires dedicated for
ф1–ф8 detector calls.