Download Parasound JC 1 Amplifier
Transcript
CONNECTING AN EXTERNAL DC SOURCE FOR AUTOMATIC TURN ON-OFF 6 If you want to automatically turn on the JC 1 with an external DC voltage, select the DC trigger by moving the Auto Turn On switch on the rear panel left to its 12 Volt Trigger position. What you’ll need: A wire with a 2.5 mm sub-mini plug on each end (provided) A “control” component with +9Vdc to +12 Vdc trigger voltage 2.5 mm sub-mini plug Before Connecting Remove power to all the components in your audio system. Make sure the Auto Turn On switch on the rear panel is in its 12 Volt Trigger (left) position. To Connect 1 Plug one end of the trigger wire into the 12V Input jack on the JC 1. 2 Plug the other end of this wire into the external DC source. Auto Turn On Delay Seconds Sensitivity Input mV None 4 12 8 20 50 200 100 < Select < < 12 Volt Trigger Audio Signal Manual 12V Input Trigger 1 2 Input Output CONTROL COMPONENT YOU SHOULD KNOW If the component controlling your JC 1 doesn’t have a 2.5 mm trigger output connector, you can cut one plug off the trigger wire and terminate the end as required. The lead with the red stripe is positive and the lead without the stripe is negative.