Chassis Group
chassisTempAlarm (chassisGrp 13)
Provides the chassis temperature alarm status.
Syntax:
Access:
Integer {
off (1)
Temperature within normal range
on (2)
Temperature too high
critical (3)
Critical temperature, system shutdown imminent
Read-only
chassisNumSlots (chassisGrp 14)
Indicates the number of slots in the chassis available for plug-in modules.
Syntax:
Integer (1..16)
Access:
Read-only
chassisSlotConfig (chassisGrp 15)
Indicates the slots in the chassis with modules inserted. The syntax is an integer value with
bits set to indicate configured modules. It can be interpreted as a sum of f(x) as x goes from
1 to the number of slots, where f(x) = 0 for no module inserted and f(x) = exp(2, x-1) for a
module inserted.
Syntax:
Integer (0..65535)
Access:
Read-only
chassisModel (chassisGrp 16)
Indicates the manufacturer’s model number for the chassis.
Syntax:
DisplayString (SIZE (0..8))
Access:
Read-only
2-18 Catalyst 5000 Series Switch Workgroup MIB User Quick Reference