Download Lantronix SCS100
Transcript
SCS100/200/400 User Guide 3: The SCS200 Specifications of the SCS200 Power Power Cube Adapter input output 120 VAC US; 100-240 VAC International 12 VDC DC power input 7-24 VDC Current 1A @ 12 V max. with PC card Power consumption 12 Watts max. Temperature Note: Rapid temperature changes may affect operation. Do not operate near heating or cooling devices or areas that open to the outdoors. Operating range 5° to 50° C (41° to 122° F) Storage range -40° to 66° C (-40° to 151° F) Max. temp change 20° C (36° F) per hour Humidity Operation 10% to 90% non-condensing Ideal 40% to 60% Storage 10% to 90% non-condensing Altitude Note: For operations above 2.4 km (8,000 ft), decrease the operating temperature rating by 1.8°C for each 1,000 m (1°F for each 1,000 ft). Operation 2.4 km (8,000 ft) Storage 9.1 km (30,000 ft) 3-4