Download Smeg CS71-5

Transcript
Instructions for the installer
3.2 Burner and nozzle characteristics table
Burner
Auxiliary
Semi rapid
Rapid
Triple crown
Burner
Auxiliary
Semi rapid
Rapid
Triple crown
Rated
heating
capacity
(kW)
1.05
1.8
3.0
3.3
Rated
heating
capacity
(kW)
1.05
1.8
3.0
3.5
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
50
65
85
91
By-pass
mm
1/100
30
33
45
68
Reduced
flowrate
(W)
360
450
750
1600
Flowrate
g/h G30
Flowrate
g/h G31
76
131
218
240
75
128
214
235
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
72
97
115
133
Reduced flowrate
(W)
360
450
750
1600
3.3 Arrangement of burners on cooking hob
BURNERS
1
2
3
4
Auxiliary
Semi rapid
Rapid
Triple crown