5.4 Environmental Specifications The airborne contaminant level is class G2 or lower as defined by ISA-S71.04-1985. Table 4 lists the environmental specifications for the R210 II. Table 4. Environmental Specifications Specification Operating Requirements Temperature Ranges (for altitude ≤ 900m or 2952.75ft) 10°C to 35°C (50°F to 95°F) 1 Non-Operating Requirements -40°C to 65°C (-40°F to 149°F) Temperature Ranges (for altitude > 900m or 2952.75ft) 10°C to T °C (50°F to T2°F) Temperature Gradient (maximum per 60 minutes) 10°C 20°C Humidity Percent Ranges (noncondensing) 20% to 80% (maximum wet bulb temperature = 29°C) 5% to 95% (maximum wet bulb temperature = 38°C) Humidity Gradient (maximum per 60 minutes) 10% 10% Low Limits -50ft (-15.2m) -50ft (-15.2m) High Limits 10,000ft (3048m) 35,000ft (10,668m) ISA-71 Level G1 – Maximum corrosive contaminant levels measured at ≤ 50% relative humidity. See Table 3 in ISA-71.04-1985. Altitude Ranges Airborne contaminants 1 Use the formulas in Figure 9 to calculate the maximum operating temperature (in °C) for a given altitude. Use the first formula if the altitude is stated in meters; use the second formula if the altitude is stated in feet. 2 Use the formulas in Figure 10 to calculate the maximum operating temperature (in °F) for a given altitude. Use the first formula if the altitude is stated in meters; use the second formula if the altitude is stated in feet. Figure 9. Formulas for Maximum Operating Temperature for Given Altitude (°C) Figure 10. Formulas for Maximum Operating Temperature for Given Altitude (°F) Dell PowerEdge R210 II Technical Guide 23