Download ClearOne XAP 800
Transcript
116 Appendices ~ Appendix E: Serial Commands MINIT - Modem Initialization String This command sets/reports the modem initialization string of the serial port when in modem mode. Command form: DEVICE MINIT [String] Argument details Name Device MINIT String Description 0–7 or * to select all units Command form 1-80 characters (select string characters to be sent to the modem when the unit is initialized CLEAR = clears the modem initialization string Null = Current string Example: #56 MINIT ATZ On XAP 800 unit 6 (#56), the modem initialization string (MINIT) is ATZ. MINMAX - Minimum and Maximum Gain Setting This command changes or reports back the minimum and maximum gain setting for an input, output or assignable processing block. Command form: DEVICE MINMAX <Channel> <Group> [Minimum] [Maximum] Argument details Name Device MINMAX Channel Group Minimum Maximum Description 0–7 or * to select all units Command form See Groups and Channels I, O, M, P, L -65.00 to 20.00, Null to return current settings -65.00 – 20.00 Example: #55 MINMAX 2 M -12 10 On XAP 800 unit 5 (#55), the minimum and maximum (MINMAX) relative gain settings for mic (M) channel 2 are -12dB and 10dB respectively. Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760