CAUTION: When correcting a PSU mismatch, replace only the PSU
with the flashing indicator. Swapping the opposite PSU to make a
matched pair can result in an error condition and unexpected
system shutdown. To change from a High Output configuration to
a Low Output configuration or vice versa, you must power down
the system.
CAUTION: AC power supplies support both 220 V and 110 V input
voltages. When two identical power supplies receive different
input voltages, they can output different wattages, and trigger a
mismatch.
CAUTION: All power supplies used must be of the same type and
have the same maximum output power.
C
Not lit
Power is not connected.
I/O module indicators
Figure 10. I/O module indicators (pass-through module)
Figure 11. I/O module indicators (switch module)
1.
power indicator
2.
status indicator
The indicators provide the following information:
Indicator
Power indicator
Description
Green
The I/O module is operating normally.
Off
The I/O module is powered off.