Transcript
Intel® Server System SR1600UR TPS Appendix C: POST Code Errors POST Error Beep Codes The following table lists the POST error beep codes. Prior to system video initialization, the BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user-visible code on the POST Progress LEDs. For complete details, refer to the Intel® S5500/S5520 Server Board Family BIOS External Product Specification. Table 49. POST Error Beep Codes Beeps 3 Error Message Memory error POST Progress Code 0xE8, 0xEB, 0xED, 0xEE Description System halted because a fatal error related to the memory was detected. The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Codes that are common across all Intel® server boards and systems that use same generation chipset are listed in the following table. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit. For complete details, refer to the Intel® Server System Integrated Baseboard Management Controller Core External Product Specification. Table 50. Integrated BMC Beep Codes Code Reason for Beep Associated Sensors Supported 1-5-2-1 No CPUs installed or first CPU socket is empty. CPU Missing Sensor Yes 1-5-4-2 Power fault: DC power unexpectedly lost (power good dropout). Power unit – power unit failure offset. Yes 1-5-4-4 Power control fault (power good assertion timeout). Power unit – soft power control failure offset. Yes Revision 1.8 Intel order number E45725-010 79