4. Blockage procedure
WARNING!
For your own safety please
remember to unplug the machine when not
in use and before carrying out maintenance.
IMPORTANT Please check your DCO1 for blockages if you notice that the vacuum cleaner stops picking up, the sound of the vacuum
cleaner changes pitch, or the suction reduces or stops altogether. Any ‘Blockage only’ repairs will incur a charge of £35.00*, so please
check your machine carefully.
*Price correct at time of printing.
1. Check filters
4. Check belt & soleplate
Filter life is dependent on the amount
the vacuum cleaner is used.
1 Remove three screws to
undo soleplate.
2
The S-level filter must be replaced
at least every 3 months.
3
2 Lift soleplate to remove.
1
3 Check condition of belt
The HEPA filter must be replaced
at least every 12 months.
IMPORTANT Use only genuine Dyson filters.
and replace if necessary.
(See 'Changing the belt'
section in your
instructions).
1
1
Check that soleplate
4 passage is clear and
2. Clean shroud
4
remove blockages if
necessary.
1 Wipe shroud holes free
of all dust/debris.
1
2 Check air duct behind
bin for debris.
5. Check cleaner head & flaps
Turn machine upside
down. Remove soleplate.
Raise inspection flap 1
and look down through
aperture. If you cannot see
daylight, remove any
blockage with a stiff wire.
2
3. Check wand/hose
1
1 Remove wand handle
from machine.
2
Rotate cleaner head so that
opening 2 becomes
exposed, keeping
inspection flap raised.
1
2 Look down wand and
check for daylight.
Remove any blockage
with a stiff wire.
3
2
3 Remove clear bin and
cyclone top, by lifting
up until it releases.
Then gently pull off
from ball socket.
4
Look through 2 to see if
light is visible and to check
that the passage is clear of
any blockages.
6. Check yellow bin inner
Check that yellow bin
inner is in place,
especially if you have
washed it. (See ‘How to
use’ section in your
instructions).
Cone seal
4 Remove hose from
machine by pressing
yellow button behind
bin cavity.
Do not remove cone seal.
Check cone seal is in
place: failure to do so
could result in clogging
of the pre-filter and
damage to the motor.
5 Check for any
click
6
5
blockages in hose and
remove.
6 When returning hose,
ensure the yellow button
‘clicks’ into place. (A
tool may be required to
ease re-assembly).
Cone seal
The lip of the cone seal
should sit over the rim
of the yellow bin inner.
DYSON CUSTOMER CARE
If you are still unable to get ‘suction’, call
Dyson Customer Care on
01666 827272.
T ET B U RY
HILL
MALMESBURY
W I LTS H I R E
EN G L AN D
S N 16 O R P