Download Dyson DCO1 User's Manual
Transcript
4. Blockage procedure WARNING! For your own safety please remember to unplug the machine when not in use and before carrying out maintenance. IMPORTANT Please check your DCO1 for blockages if you notice that the vacuum cleaner stops picking up, the sound of the vacuum cleaner changes pitch, or the suction reduces or stops altogether. Any ‘Blockage only’ repairs will incur a charge of £35.00*, so please check your machine carefully. *Price correct at time of printing. 1. Check filters 4. Check belt & soleplate Filter life is dependent on the amount the vacuum cleaner is used. 1 Remove three screws to undo soleplate. 2 The S-level filter must be replaced at least every 3 months. 3 2 Lift soleplate to remove. 1 3 Check condition of belt The HEPA filter must be replaced at least every 12 months. IMPORTANT Use only genuine Dyson filters. and replace if necessary. (See 'Changing the belt' section in your instructions). 1 1 Check that soleplate 4 passage is clear and 2. Clean shroud 4 remove blockages if necessary. 1 Wipe shroud holes free of all dust/debris. 1 2 Check air duct behind bin for debris. 5. Check cleaner head & flaps Turn machine upside down. Remove soleplate. Raise inspection flap 1 and look down through aperture. If you cannot see daylight, remove any blockage with a stiff wire. 2 3. Check wand/hose 1 1 Remove wand handle from machine. 2 Rotate cleaner head so that opening 2 becomes exposed, keeping inspection flap raised. 1 2 Look down wand and check for daylight. Remove any blockage with a stiff wire. 3 2 3 Remove clear bin and cyclone top, by lifting up until it releases. Then gently pull off from ball socket. 4 Look through 2 to see if light is visible and to check that the passage is clear of any blockages. 6. Check yellow bin inner Check that yellow bin inner is in place, especially if you have washed it. (See ‘How to use’ section in your instructions). Cone seal 4 Remove hose from machine by pressing yellow button behind bin cavity. Do not remove cone seal. Check cone seal is in place: failure to do so could result in clogging of the pre-filter and damage to the motor. 5 Check for any click 6 5 blockages in hose and remove. 6 When returning hose, ensure the yellow button ‘clicks’ into place. (A tool may be required to ease re-assembly). Cone seal The lip of the cone seal should sit over the rim of the yellow bin inner. DYSON CUSTOMER CARE If you are still unable to get ‘suction’, call Dyson Customer Care on 01666 827272. T ET B U RY HILL MALMESBURY W I LTS H I R E EN G L AN D S N 16 O R P