Download Graco 333282B User's Manual
Transcript
Installation J11 on the first color control module to J7 on the second module. 6. Replace the cover of the PD2K electrical control box before turning on power to the system. Install the Remote Valve Manifolds 1. Using the equipment as a template, mark the mounting holes on the wall at a convenient height for the operator and so the equipment is easily accessible for maintenance. Mount the remote valve manifolds near the remote color module and the automatic dispensing device. 2. Install the mounting brackets for the color valve manifolds and the catalyst valve manifolds. See Dimensions, page 71. Use bolts to attach the equipment securely. Figure 10 Detail of Isolation Board Cable Connections 5. If your system includes a second remote color control module mount it as described in Mounting the Control Modules, page 18. Connect the supplied hazardous location cable (C2) from 333282B 3. Install the color and catalyst valve manifolds to the brackets with four screws, washers, and nuts. 4. Connect the air lines from the solenoids to the valves. See Connect the Valve Air Lines, page 24. 5. Connect the fluid supply lines to the valves. See Connect the Fluid Lines, page 26. 23