Download Texas Instruments TMS320 User's Manual

Transcript
TMS32020
SPRS010B — MAY 1987 — REVISED NOVEMBER 1990
timing requirements over recommended operating conditions (see Note 3)
MIN
MAX
UNIT
597
ns
CLKIN fall time
10†
ns
tr(CI)
CLKIN rise time
10†
ns
tw(CIL)
CLKIN low pulse duration, tc(CI) = 50 ns (see Note 4)
40
ns
tw(CIH)
CLKIN high pulse duration, tc(CI) = 50 ns (see Note 4)
40
ns
tsu(S)
SYNC setup time before CLKIN low
10
th(S)
SYNC hold time from CLKIN low
15
tc(C)
tf(CI)
CLKIN cycle time
195
NOM
Q – 10
ns
ns
† Value derived from characterization data and not tested.
NOTES: 3. Q = 1/4tc(C).
4. CLKIN duty cycle [tr(CI) + tw(CIH)] / tc(CI) must be within 40-60%.
ADVANCE INFORMATION
2.15 V
RL = 825 Ω
From Output
Under Test
Test
Point
CL = 100 pF
Figure 3. Test Load Circuit
2.0 V
VIH (Min)
1.88 V
0.92 V
VIL (Max)
0.80 V
0
(a) Input
2.4 V
VOH (Min)
2.2 V
0.8 V
VOL (Max)
0.6 V
0
(b) Output
Figure 4. Voltage Reference Levels
POST OFFICE BOX 1443
•
HOUSTON, TEXAS 77001