Download Xilinx UG018 User's Manual
Transcript
R Table 2-12: Data-Side PLB Interface I/O Signal Summary (Continued) I/O Type If Unused Function PLBC405DCURDDACK I 0 Indicates the DCU read-data bus contains valid data for transfer to the DCU. PLBC405DCURDDBUS[0:63] I 0x0000_0000 _0000_0000 The DCU read-data bus used to transfer data from the PLB slave to the DCU. PLBC405DCURDWDADDR[1:3] I 0b000 PLBC405DCUWRDACK I 0 Indicates the data on the DCU write-data bus is being accepted by the PLB slave. PLBC405DCUBUSY I 0 Indicates the PLB slave is busy performing an operation requested by the DCU. PLBC405DCUERR I 0 Indicates an error was detected by the PLB slave during the transfer of data to or from the DCU. Signal Indicates which word or doubleword of an eightword line transfer is present on the DCU read-data bus. Data-Side PLB Interface I/O Signal Descriptions The following sections describe the operation of the data-side PLB interface I/O signals. Throughout these descriptions and unless otherwise noted, the term clock refers to the PLB clock signal, PLBCLK. See “PLBCLK (Input)” for information on this clock signal. The term cycle refers to a PLB cycle. To simplify the signal descriptions, it is assumed that PLBCLK and the PowerPC 405 clock (CPMC405CLOCK) operate at the same frequency. C405PLBDCUREQUEST (Output) When asserted, this signal indicates the DCU is presenting a data-access request to a PLB slave device. The PLB slave asserts PLBC405DCUADDRACK to acknowledge the request. The request can be acknowledged in the same cycle it is presented by the DCU. The request is deasserted in the cycle after it is acknowledged by the PLB slave. When deasserted, no unacknowledged data-access request exists. The following output signals contain information for the PLB slave device and are valid when the request is asserted. The PLB slave must latch these signals by the end of the same cycle it acknowledges the request: x C405PLBDCURNW, which specifies whether the data-access request is a read or a write. x C405PLBDCUABUS[0:31], which contains the address of the data-access request. x C405PLBDCUSIZE2, which indicates the transfer size of the data-access request. x C405PLBDCUCACHEABLE, which indicates whether the data address is cacheable. x C405PLBDCUWRITETHRU, which specifies the caching policy of the data address. x C405PLBDCUU0ATTR, which indicates the value of the user-defined storage attribute for the instruction-fetch address. x C405PLBDCUGUARDED, which indicates whether the data address is in guarded storage. PowerPC™ 405 Processor Block Reference Guide UG018 (v2.0) August 20, 2004 www.xilinx.com 1-800-255-7778 73