Download Operating Instructions Safety Switch CET.-AS-...-CB
Transcript
Operating Instructions Safety Switch CET.-AS-...-CB-... Closing safety guard and activating guard locking The safety door can be opened as long as the lift tappet is held in the extended position. Switching the guard locking solenoid on via AS-Interface output bit D0 releases the lift tappet. The actuator's guard locking pin can now press the lift tappet down. The safety door is locked and the solenoid monitoring contact is closed as soon as the guard locking pin is fully inserted into the recess. The complete safety code sequence is sent via AS-Interface input bits D0 to D3. Deactivating guard locking Switching the guard locking solenoid off via AS-Interface output bit D0 extends the lift tappet and raises the actuator's guard locking pin over the edge of the recess. The half-sequence is sent via AS-Interface input bits D0 and D1 in every bus cycle. Opening safety guard Opening the safety door moves the actuator out of the operating distance. The values 0, 0, 0, 0 are continuously sent via AS-Interface input bits D0 to D3. 9