Download IBM Netfinity ServeRAID User's Guide - ps

Transcript
Ÿ SID with the SCSI ID for the device (0 to 15)
FORMAT
Use the FORMAT command to perform a low-level format of a
hard disk drive.
Attention:
When you issue this command, all data on the drive will be lost.
Supported operating system: DOS
Command:
IPSSEND FORMAT Controller Channel SID
Replace:
Ÿ Controller with the ServeRAID controller number (1 to 8)
Ÿ Channel with the channel number for the device (1, 2, or 3)
Ÿ SID with the SCSI ID for the device (0 to 15)
GETEVENT
Use the GETEVENT command to display information about
various unexpected events. IBM uses the Soft and Hard Event
Logs for development and debugging purposes only. The Device
Event Log contains event counters for each attached physical
device. These counters include:
Ÿ Parity: An unexpected event while transferring data on the
SCSI bus. This usually indicates a problem with the SCSI
cable, connectors, or terminators.
Ÿ Soft: A SCSI device detected a check condition event.
Ÿ Hard: The SCSI controller detected an unexpected event.
The controller is the most likely cause.
Ÿ Misc: The ServeRAID adapter or controller detected an event
that was most likely caused by the device.
The Device Event Log also provides predictive failure analysis
(PFA) alerts, which indicate that the device has signaled the
ServeRAID adapter or controller that it might fail in the near future.
Supported Operating Systems: Windows NT, OS/2, NetWare,
OpenServer, UnixWare, and DOS
Command:
IPSSEND GETEVENT Controller Options
Replace:
Ÿ Controller with the ServeRAID controller number (1 to 8)
Ÿ Options with one of the following: DEVICE for Device Event
Log, SOFT for the ServeRAID adapter or controller Soft Event
Log, or HARD for the ServeRAID adapter or controller Hard
Event Log.
SELFTEST
The SELFTEST command is used to direct an adapter or a device
to perform its self-test.
Supported operating systems: DOS
Command:
IPSSEND SELFTEST Controller Options
Replace:
Chapter 4. Starting and Using the Utility Programs
81