Download Invacare ® TDX-SP / TDX

Transcript
Invacare ® - TDX-SP / TDX-SP N
SERVICE MANUAL
●
Make a marking on the motor and the carbon brushes in order to guarantee correct refitting.
●
Remove the carbon brushes complete from the mounting (2).
●
Check the carbon brushes and springs for the level of wear, broken components or
discolouration.
Refitting the carbon brushes:
● Depending on the condition of the brushes and the spring:
- either replace the brushes in exactly the same position from which they were taken or
- fit new brushes.
●
Replace the plastic caps and tighten them.
●
Refit the top walking beams as described in Chapter 8.13.2.
●
Refit the bottom walking beams as described in Chapter 8.12.
●
Refit the drive wheels as described in Chapter 8.9.1.
Note
The following procedure is necessary to run the carbon brushes in after replacement and to
therefore guarantee maximum performance.
WARNING: Risk of accidents!
Hazards to workers, surroundings and mobility device!
● Do not leave the mobility device unattended during the following procedure!
● Make sure that BOTH drive wheels are off the ground before calibrating.
● Secure the area.
●
Lift the mobility aid up on one side and place a 14 cm high wooden block underneath it so that
the drive wheel is suspended freely. Use proper lifting techniques.
●
Repeat the same procedure on the other side of the mobility aid.
●
Allow the motors to run in the forward direction for an hour.
●
Allow the motors to cool down for 30 minutes.
●
Allow the motors to run in the reverse direction for an hour.
●
Lift the mobility aid off the wooden blocks.
113