SRAM CORPORATION • PIKE USER MANUAL
Under ‘Lock’, heavier riders may find better performance with maximum Floodgate
settings, while lighter riders may find minimum Floodgate settings work best.
Experiment with higher or lower Floodgate settings while on the trail to optimize your
fork for your riding style and performance preferences.
Use the charts below to establish an initial Floodgate setting.
Al l se t tin g s f rom M aximu m F lo od gat e (o r fu ll cl ockwis e)
E X T E R N A L F L O O D G AT E ( R A C E
AND
TEAM MODELS)
Rider weight lb (kg)
Full Turns Counterclockwise
< 120 (< 54 kg)
120 - 150 (54 - 68 kg)
150 - 180 (68 - 82 kg)
180 - 210 (82 - 95 kg)
210 < (95 kg < )
4-5
3-4
2-3
1-2
0-1
SRAM CORPORATION • PIKE USER MANUAL
ENGLISH
COMPRESSION ADJUSTMENT (FIG. 4)
Some fork models also feature adjustable compression damping. Increased compression
decreases fork movement in the ‘Open’ position. Compression adjustment can be used to
help combat brake dive and "squatting" under hard cornering.
For crown activated forks, compression damping increases to ‘Lock’ as the crownmounted actuator rotates 90 degrees clockwise. Position the actuator anywhere within
the range from ‘Open’ to ‘Lock’ to suit the desired level of compression damping.
Forks equipped with the PopLoc Adjust provide compression damping adjustment for
the ‘Open’ position. Turning the blue adjuster on the PopLoc adjust clockwise increases
compression damping for the ‘Open’ position. The PopLoc lever features gradients to
help illustrate the current level of compression. Eight complete turns of adjustment are
provided.
TIP: ADJUSTING COMPRESSION ON FORKS EQUIPPED WITH POPLOC ADJUST IS BEST DONE WITH THE FORK IN
‘LOCK’ POSITION.
I N T E R N A L F L O O D G AT E ( S L M O D E L )
Rider weight lb (kg)
Full Turns Counterclockwise
< 120 (< 54 kg)
120 - 150 (54 - 68 kg)
150 - 180 (68 - 82 kg)
180 - 210 (82 - 95 kg)
210 < (95 kg < )
2.0 +
1.5 - 2.0
1.0 - 1.5
0.5 - 1.0
0.0 - 0.5
NOTE: THE COMPRESSION SETTING DOES NOT ADVERSELY EFFECT YOUR FORK'S PERFORMANCE OVER HIGH
SPEED IMPACTS.
Compression Range
Select compression damping
between 'Open' and 'Lock'
TIP: THE REBOUND ADJUSTER ON THE BOTTOM RIGHT FORK LEG CAN BE USED TO ADJUST INTERNAL
FLOODGATE MODELS. GENTLY PULL DOWNWARD ON THE REBOUND ADJUSTER FOR REMOVAL. REMOVE THE
GOLD ‘GATE’ DUST CAP AND INSERT THE 2.5MM HEX END OF THE REBOUND ADJUSTER INTO THE FLOODGATE.
DON'T FORGET TO RE-INSTALL THE ADJUSTER AFTER USE!
Turning the compression adjuster on the PopLoc Adjust
sets how far the lever returns from 'Lock' toward the 'Open'
position. This adjustment changes the amount of
compression damping found in the 'Open' position.
Fork movement
ENGLISH
Remote
Compression
Adjuster
Floodgate Adjustment
('Lock' blowoff force when the fork is in 'Lock' mode)
Force
High
Medium
Low
Floodgate Setting
Maximum
Floodgate in full
clockwise position.
High input force
needed to overcome
the 'Lock.'
Minimum
Floodgate turning
Floodgate in full
counterclockwise.
counterclockwise position.
Medium input force
Low input force
needed to overcome
needed to overcome
the 'Lock.'
the 'Lock.'
Crown mounted adjuster
PopLoc Adjust Remote
Fig. 4
External
Floodgate
Internal
Floodgate
Fig. 3
10
954-308965-000, REV. B
SRAM CORPORATION • MARCH 2004
11