Download ArcturusXT™ Laser Capture Microdissection System User Guide

Transcript
Chapter 3 Starting the System and Loading Samples
Optical
path
Position
L80
Light
Distribution
Left Side
Port 80% /
Eyepiece
Port 20%
Use on
ArcturusXT
Instrument
Microdissection
3
Details of Suggested Use
The live video camera for the ArcturusXT Instrument is
installed in the left microscope port. To view the image using
the operating software, you must select either the L100 or
L80 optical paths. The ArcturusXT operating software will
default to the L100 position when initiated.
Note: To use the L80 position, you must also have the
optional Microscope Binoculars (PN 0200-6228).
Use this selection to view the sample through the eyepieces
while simultaneously displaying it through the operating
software.
R100
Right Side
Port 100%
High
Resolution
Imaging
If you have installed the optional High Resolution Second
Camera for the ArcturusXT Instrument (PN14379-00) it is
installed in the right microscope port. To use this optional
camera for high-resolution imaging, select the R100
position.
Note: The optional High Resolution Second Camera is
intended only for imaging and is not available for
microdissection. Microdissection can only be performed
using the integrated ArcturusXT Instrument camera
mounted in the left port (position L100 or L80).
Reseting the Z-position with the Z-reset button
Press the Z-Reset butotn to reset the Z-position on the Status Display window to zero.
The Z-axis position display will be increased or decreased in conjunction with
movement of the nosepiece, with the zero position as the new reference point.
The ArcturusXT operating software recognizes the absolute Z-position of the objective
nosepiece. If you press the Z-Reset button, the focus position on the ArcturusXT
software interface will no longer match the Z-position read-out on the Status Display
window. If you want to realign the values between the ArcturusXT software interface
and the Status Display window, you must turn the instrument off and then on again,
and restart the operating software.
Disabling the Perfect Focus buttons (PFS)
The Perfect Focus buttons (marked PFS on the panel) are disabled when you are using
the ArcturusXT Instrument. These controls are used for the Perfect Focus System
option, which is not available for the ArcturusXT Instrument.
Selecting the magnification level with the Magnification Selection knob
Use the Magnification Selection knob to change between 1X and 1.5X objective
magnification. Apply this setting for all microscope output ports.
ArcturusXT™ Laser Capture Microdissection System User Guide
27