Chapter 3 Starting the System and Loading Samples Optical path Position L80 Light Distribution Left Side Port 80% / Eyepiece Port 20% Use on ArcturusXT Instrument Microdissection 3 Details of Suggested Use The live video camera for the ArcturusXT Instrument is installed in the left microscope port. To view the image using the operating software, you must select either the L100 or L80 optical paths. The ArcturusXT operating software will default to the L100 position when initiated. Note: To use the L80 position, you must also have the optional Microscope Binoculars (PN 0200-6228). Use this selection to view the sample through the eyepieces while simultaneously displaying it through the operating software. R100 Right Side Port 100% High Resolution Imaging If you have installed the optional High Resolution Second Camera for the ArcturusXT Instrument (PN14379-00) it is installed in the right microscope port. To use this optional camera for high-resolution imaging, select the R100 position. Note: The optional High Resolution Second Camera is intended only for imaging and is not available for microdissection. Microdissection can only be performed using the integrated ArcturusXT Instrument camera mounted in the left port (position L100 or L80). Reseting the Z-position with the Z-reset button Press the Z-Reset butotn to reset the Z-position on the Status Display window to zero. The Z-axis position display will be increased or decreased in conjunction with movement of the nosepiece, with the zero position as the new reference point. The ArcturusXT operating software recognizes the absolute Z-position of the objective nosepiece. If you press the Z-Reset button, the focus position on the ArcturusXT software interface will no longer match the Z-position read-out on the Status Display window. If you want to realign the values between the ArcturusXT software interface and the Status Display window, you must turn the instrument off and then on again, and restart the operating software. Disabling the Perfect Focus buttons (PFS) The Perfect Focus buttons (marked PFS on the panel) are disabled when you are using the ArcturusXT Instrument. These controls are used for the Perfect Focus System option, which is not available for the ArcturusXT Instrument. Selecting the magnification level with the Magnification Selection knob Use the Magnification Selection knob to change between 1X and 1.5X objective magnification. Apply this setting for all microscope output ports. ArcturusXT™ Laser Capture Microdissection System User Guide 27