Transcript
red Chapter 9 PRACTIKA 28-33 USE AND INSTALLATION MANUAL page 47 FOR EXAMPLE: 65°C H2O OFF 21.04 Fire:5 TH2O:75°C Esc < Setting Set Esc < Setting Esc < > Set Language > Esc < Menu Set > ON Ok Language > 9.2.2. ECO mode The boiler is factory set to AUTO-ECO mode, which means: when the external thermostat is satisfied, the boiler modulates at power level 1 for a brief period of time, after which - if the thermostat continues to be satisfied - the boiler shuts down. The boiler starts up again automatically only when the external thermostat requests heat again (not before an interval required for the boiler to cool down). 9.2.2.1. Enabling/disabling ECO mode When this option is enabled, the control panel display shows the wording ECO ENABLED. In the first screenshot with the word OFF, press any key to show the screenshot with the word MENU. Using the bottom right key, scroll through until you find the word SETTINGS, press the top left key relating to SET, scroll through again with the bottom right key until the wording AUTO-ECO is shown. Select SET at the top right again and using the bottom left or right key, set OFF or ON and press OK to save your setting. When the ECO function is enabled, the start screenshot will show alternately the boiler operating status and the wording ECO ENABLED. To disable the AUTO-ECO function, follow the same procedure. With this function disabled, when the external thermostat is satisfied (contact open), the boiler will modulate at minimum power, shutting down only if the temperature set in the boiler is exceeded by 5°C. Menu structure Technical dept. - All rights reserved - Reproduction prohibited