Technical Data * Type of steering Steering operation BMP 8500 Articulated joint hydrostatic Vibration system Vibrating drum Drive system Frequency Amplitude Centrifugal force Hz mm kN front + rear hydrostatic 42 1.12/0.56 72/36 Filling capacities Fuel (diesel) Hydraulic oil Engine oil Coolant Vibration housing l l l l l 24 17 4.7 4.5 2x 1,7 m PL c > 1.20 Safety field system Performance level Reach of the safety field infront of/behind the machine Safety field control Voltage Current consumption @ 12 V Protection class Safety field frequency Operating temperature Storage temperature V A Transponder (in remote control) Voltage (cable operation) Voltage (battery operation) Transmitting frequency range Operating temperature Storage temperature Safety field antenna Protection class Operating temperature Storage temperature kHz °C °C 8 ... 30 1.5 IP 55 125 -20 ... +80 -40 ... +85 V V MHz °C °C 9 ... 30 3.6 868/916 -20 ... +80 -40 ... +85 °C °C IP 55 -20 ... +85 -40 ... +85 Radio remote control Manufacturer HETRONIC Transmitter Frequency band Transmitting frequency range Number of channels Reach, depending on environment BMP 8500 MHz m BOMAG F-band 868 / 916 1 approx. 30 9