Download 5300T Service Manual
Transcript
ELECTRICAL TO REPLACE MAIN CIRCUIT BREAKERS FOR SAFETY: Before Leaving Or Servicing Machine; Stop On Level Surface, Turn Off Machine. FOR SAFETY: Disconnect the battery connections before working on the machine. 1. Disconnect the wires from the circuit breaker. 2. Carefully pry the retaining clip off the backside of the breaker using a straight screwdriver. 3. With the replacement breaker properly positioned into its location on the panel, side the new retaining clip securely into position. 4. Reconnect the wires to the circuit breaker. See schematic in this section. TO REPLACE BRUSH PRESSURE AND AMP GAUGE FOR SAFETY: Before Leaving Or Servicing Machine; Stop On Level Surface, Turn Off Machine. FOR SAFETY: Disconnect the battery connections before working on the machine. 1. Disconnect wires 8 and 10 from the two terminal studs on the back of the gauge using a 5/16 inch wrench. 2. Remove the two nuts that secure the gauges mounting bracket against the panel, using a 5/16 inch wrench. 3. When installing the replacement gauge, position the gauge properly into its location on the panel and connect wire 8 and 10 to the two terminal studs. DO NOT over tighten the wire connections or damage may occur to the gauge. 4. With the gauge properly positioned, install the mounting bracket to the back of the gauge and snug down the two nuts that hold the gauge in place. 4Ć8 5300T MM382 (10–94) Home Find... Go To..