Download Bladed for Windows User Manual

Transcript
Garrad Hassan and Partners Ltd
Document:282/BR/010
ISSUE:11
FINAL
5. CONTROL SYSTEMS
Click the Control icon on the toolbar to open the Control Systems screen. This allows
definition of the power production control characteristics as well as supervisory control
functions.
Power production control
Power production control models are available for pitch or stall regulated, fixed or variable
speed turbines.
Select one of the following options:
1. Fixed speed stall regulated5.1 : the induction generator model should be selected.
2. Fixed speed pitch regulated5.2 : the induction generator model and a pitch or aileron
controlled rotor should be selected.
3. Variable speed stall regulated5.3 : the variable speed generator model should be selected.
4. Variable speed pitch regulated5.4 : the variable speed or variable slip generator model
should be selected, and a pitch or aileron controlled rotor.
See: Generator4.8, Drive train4.6 , Defining the rotor4.1.
The steady state parameters define the operating envelope of the turbine, and are required for
calculation of the steady power curve and steady operational loads. Click on Controller
Dynamics to define additional parameters which model the dynamic action of the
controller, such as controller gains and transducer and actuator time constants.
The different power production control models are described in Sections 5.2 to 5.7 below.
Further details of the power production controllers is provided in the Theory Manual. It is
also possible for user-defined control logic to be used - see Section 5.8.
Supervisory control
The Supervisory control screens may also be accessed by clicking the Control icon on the
toolbar.
Use the Supervisory control screens to define the characteristics of the following:
•
•
•
•
•
•
•
•
•
Shaft brake5.11
Start-up sequence5.12
Normal stop sequence5.13
Emergency stop sequence5.14
Idling conditions5.15
Parked conditions5.16
Yaw control.5.17
User-defined controllers. 5.8
Pitch actuators. 5.10
In-built supervisory control logic is available for stops and starts, but the user may also
supply the required logic for these5.8, as well as for yaw control.
31 of 116