Star-delta start:
The motor protection switch shall be
included in the delta circuit and
adjusted to 0.58 times the nominal
power maximum.
Motors with additionally installed
PTC-resistor sensors:
- Test voltage of PTC-sensors 1.5 V
max.!
- To be operated with a tripping aid
only!
The pump shall be stopped
immediately after starting.
Dry-running of the pump will
destroy the shaft sealing.
By rotation sense control, the pump
shall be safeguarded so that no
personal injury can happen by a
rotating impeller. Avoid gripping into
the pressure pipe joint or the suction
opening of the pump casing.
EX:
If the thermal winding protector
optionally installed performs the
tripping, the system must not start
again automatically unless the
malfunction is checked and corrected
again.
5.9
Rotation sense control
Three-phase current motor shall be subject to a thorough
rotation sense control, at first start-up and when re-started
on a new installation site. Rotation in the wrong direction
means less pumping output and may damage the pump.
When viewed on the motor fan, the
latter shall rotate clockwise.
Rotation
sense
conforming to the rotation
arrow!
24
At a control system with several
pumps, each pump shall be tested
individually.
If an explosion hazard exists also
during installation, the rotation sense
must in no case be checked by
momentary starting the empty pump.
5.9.1 Changing the rotation sense
At incorrect rotation sense, the direct shall be reversed by
commuting two phases of the lead cable in the control
system.