Download Installation Manual

Transcript
Exsulite™ Thermal Facade System
Wall cladding solutions for certifiers & builders
How does a Cavity System work?
AcraTex - is a pioneer in the use of EIFS systems, designing
and installing systems specifically for Insulation benefits as
originally used in Europe. In recent years the use of Lightweight
Cladding Systems, as Alternate Solutions in the BCA, has grown
but proper system design and installation has not followed.
The BCA requires appropriate design and installation controls
to qualify any Alternate Solution and ultimate success requires
a total systems approach integrating Design, Componentry
& Installation. The Exsulite™ Thermal Facade system protects
surveyors, builders and their Clients from the risks of mixed
componentry and uncontrolled installation. Exsulite™ by Dulux®
AcraTex® offers a Single Supply Source for the Total Facade
System - Cladding to Weatherproofing Coating
The Exsulite™ Thermal Facade Cavity System is
recommended in areas with significant variation between
internal and external temperatures. If condensation occurs,
moisture can efficiently drain from the cavity through the
specially designed starter beads and provide airflow
throughout the entire cavity.
Exsulite™ EPS Panel
The four key elements of a cavity & moisture management
system.
®
Exsulite™ Thermal M-Grade Panels can be cut to any
desired thickness but dependant on application and
required “R” value we recommend from a range of standard
panels; 60mm, 75mm, 100mm. The sheet dimensions are
2500mm x 1200mm and are manufactured to meet the
requirements of AS 1366.3 – 1992.
The cavity separates the cladding material from the timber
framing. It protects the timber framing from any occasional
leaking by providing a gap allowing water to drain down
the back of the cladding and out through the base of the
cavity. Any remaining moisture within the cavity is able to
dry through ventilation provided along the bottom edge of
the cavity.
•D
eflection: The first line of defence is a well designed
and constructed cladding system to ‘deflect’ the water
away.
•D
rainage: A cavity provides a second line of defence
by ‘draining’ away water that may leak behind the
cladding.
•D
rying: By ventilating the cavity, any moisture that has not
drained away is removed by ‘drying’.
•D
urability: Materials for wall and cavity construction must
be sufficiently ‘durable’ to resist decay for a period that
will allow time for a leak to be discovered and repaired.
Dulux® Exsulite™ Trained Installer Network
An Exsulite™ Certificate of Installation from a registered
Exsulite™ Installer provides peace of mind that “as built”
meets Design Specification. All Exsulite™ Trained Installers
can be verified by their Exsulite™ Identification Card and
Registration number. Project QA Process is a critical element
of the Exsulite™ Total System approach and the Exsulite™
Installer Network ensures Total Facade System compliance From Start to Finish.
Install
Finish
er Ch
ecklis
Appli
aroun ed PU
se
Back
overc d wind alant
blockin
to
memb oat se ows, me expa
g req
uired
rane alant wi ter bo nsion
check
and if
)
th Ba x an joints,
Exter
ed exp
so by
co
nal
seco d oth
ansion
who.
PVc
Vertica
at or er pe ntrol joi
joint
TM
Protec
angle
locatio
nts,
Textur netra
expans l expansion
ns and
tive
s ins
e. Ov tions. and
s
ions
drop
talled
ensure
joints joints inst
ercoa (Do no
shee
d dou
and
alle
at ma
Exsul
check
t
t on
ts to
ble stud
by wh
x. 3.0 d at ma
ite Ba
Yes
ed gab
ly wi
roof
x. 6.0
s.
m cen
o.
th
se co
le are
and
m
tres
centres
a fram
.
at ap
adjac
Exsul
Backing
ing at
and hor
ite me
plied
No
ent
plates
600m
10izo
areas
.
for fixin
sh
0mnta
m ma
l
m, dia embe
.
g of dow
x. cen
Backing
comm
Gree
tres.
gona dded
n pip
plates
ents:
Yes
n Re
e bra
l strips into
to clo
ba
cke
ba
se co nder
thes line
ts bef
check
at co seco
ore pan
Yes
at ap Seale
ed flas
s, per
rners at, ov
No
el inst
golas
plica r (whe
hing
of op erlap
Da
alla
ove
and
AcraTtion.
tion).
te:
n tex
r roo
ening ped
check
other
f areas,
ture
ex tex
By W
min.
No
externa
ed win
s.
comm
coati
parape
ture
ho
dows
l fixtu
ng
en
res.
co
ts:
withi
at ap
Dampas a Qualityand
The Exsulite “certificate of installation” is for use by a Exsulite Trained & Registered installer
control
doors Documenttstoand bal
n5
proof
plied
conies. AcraT
inst
days
courseprocedures asalle
ex M
Yes
.
d wit
certify that the specified Exsulite system has been installed in accordance with the Exsulite
installation
set
out
in
Ba
of
h cor
installe
embra
tch
Exsulite
rect rev
No:
d to
Appli
ne top
breath
slab
eal size
the Exsulite installation manual & Dulux AcraTex specification.
No
rebate
able
coat
produtoedsuitin ac
Yes
absorb
.
if not
appli
ct sp cavco
ent wa
, stat
ed.
comm
ecificity.rdanc
e alte
Finish
Date:
The “certificate of installation” is used to record on site work procedures & substrate standards
for
installationll wra
of pthe
rnathe
ation e with
ents:
er sig
Qua
tive bre
installe
No
Exsulite
s
AcraT
ntity
d.
Name
athabl
n-off
Date:
Produ
ca&
Exsulite Thermal Facade System and the Application of AcraTex finishing system, signed
off
over
atejob
(bags
ex pro
vityhanded
wrapcompletion.
:
ct:
spacer
):
installe
duct
if not
installe
Date:
d.
data
, type
d.
shee
of cav for warranty
The Exsulite “certificate of installation” and Exsulite Warranty Job Registration forms are required
purposes and
Batch
Produ
ts an
ity spa
d
Exsulite
ct:
cercan
No:
Instal
installe
forms part of the Exsulite warranty procedure. The Exsulite Trained installer and Exsulite
Trained
Finisher
either be the same
panel
comm
colou
ler No
d and
thickne
r:
ents:
by
Exs
Ye
:
ss inst
who.
ulite
or separate entities who have attended the Exsulite Training course .
s
Batch
alled.
and ma screws and
No:
ximum
Qua
colou
washe
No
ntity
600m
rs
Appro
r:
Signa
m hor installed
(buck
ved alu
comm
at ma
izonta
openin
ture:
ets):
comm
ximum
lly.
ents:
gs and minium flas
cavity
ents:
275m
Qua
hing
all pen
spacer
m ver
ntity
Exsulite
Project Start Date
etration tape inst
thickne
tically
(buck
alled
panels
comm
s.
ss
Type
ets):
around
60mm
glued
ents:
window
fully alo
All exp
Site Address
75mm
s, doo
ng abu
osed
mm
panel
rs, me
tting
edges
edges
ter box
100mm
Exsulite
Project Builder
contact Number
with
fully enc
,
PVc
approv
mm
Other
losed
externa
ed foa
with
l ang
Date
m adh
PVc
contro
les fixe
contact Name
channe
esive.
of co
l Joints
d wit
l.
mplet
to ma
h app
sonry
ion:
roved
Exsulite
with 8m
Ground Level construction
adhesiv
Exsulite
Hebel
Brick
panel Other
m gap
e.
to win
and bac
dow
Detail
king rod
sills cut
Upper Level construction
at con
Exsulite
Hebel
Brick
/strip.
at min
crete Other
imum
slab
All com
10 deg
rebate
ponent
Exsulite Panel Wall Area
m2 Dulux Specification Number Ma
in acc
rees.
s hav
nual
ord
e bee
and co
ance
with
nstructi n installe
collec
Exsulite
d fully
on Det
ted all
co
in acc
ails.
nstructi
off cuts
ordanc
on det
Installe
and pla
e wit
ails.
r sign-o
h Exs
ced in
ulite
ff
clear
installa
Na
company Name
installer
me: Name
plastic
tion
bags
for rec
Exsulite installer No.
ycling
collec
Installe
Nominated installer
Mobile
tion.
r No
:
Nominated installer No
er Chec
klist (co
ntinued
t
)
Yes
No
Comm
ents/B
y Who
Certificate of Installation
Proje
ct Sp
ecifi
Item
c Ch
/Des
ecklis
cripti
t
on
Project Information
• Installer Training and Ongoing Development
Yes
Exsulite Trained Installer Entity
• Registration and Verification ID
Other
Exsulite Trained Finisher Entity
No
Com
men
men
ts
Signat
ure:
company Name
• Certificate of Installation checklist and QA sign-off
Com
installer Name
Exsulite installer No.
Date
Nominated installer
Mobile
of com
pletion
Nominated Finisher No
Site Access and Scaffolding Checklist
Yes
is all access scaffolding set up to install the specified system?
5412
Installer Checklist
/0712
is all scaffolding and access equipment checked and approved?
All Exsulite components supplied by Dulux with no substitution.
checked frame with straight edge up to 5mm tolerance.
5412/0712
Was rectification required and if so by whom?
checked frame for additional back blocking to ensure double studs at vertical
butt joints to panels.
Yes
No
Comments/By Who
On co
by em mpletio
ail to n of th
is
sale
s@ex form, it
is
sulit
e.com the resp
No Comments/By Who
.au or onsi
by fa bility of
x to
+61 the Exsu
lit
3 92
63 58 e Traine
40 as d Inst
part aller to
of jo
b regi forward
it
stra
tion to Dulu
Page 1 of 3
proc
ess. x AcraTe
x
Page
Exsulite Installation Manual - Page 5
2 of
3
Page
3 of
3
ts/By
Who