3. SPECIFICATIONS
3.1 Hardware Specifications
Number of carbon probes:
2 maximum
Carbon range:
up to 2.0%
Oxygen range:
1 x 10
Oxygen accuracy:
±1% of actual measured oxygen value with a repeatability of ±0.5% of the measured
value
Thermocouple types:
Type K, J, R, S & N
Temperature accuracy:
±2°C
Analogue outputs:
0-20mA or 4-20mA field selectable
Active outputs (Do NOT loop power these outputs)
Output load:
1000 ohm max
Alarm relays:
4
Alarm relay contacts:
2A/240VAC, 2A/30VDC
-30
to 100%
(WARNING: Do not use both mains voltage and low voltage connections to adjacent alarm contacts)
Mains voltage supply:
Overvoltage:
100 to 240VAC, -6 +10%, 50/60 Hz
Category II (IEC60364-4-443)
Power:
5W for controller plus probe power
Fuses:
3A, fast blow, 250v, 20x5mm (heater fuses, 2 of)
1A, slow blow, 250v, microfuse (PCB mtg fuse, 1 of)
Environmental Rating:
Operating Temperature -25°C to 55°C
Relative Humidity 5% to 95% (non-condensing)
2000m maximum
Altitude
Degree of Protection:
IP65
IP54 with internal reference air pump
Case Size:
260mm (10.2”) wide, 160mm (6.3”) high, 90mm (3.5”) deep
Weight:
3 Kg (6.6 lbs.)
WARNING: All signal level connections onto the controller must be treated as safety extra-low voltage (SELV) as
defined in the standard IEC61140. Double insulation must be used when connecting these terminals to systems
that might carry high voltage.
March 2009
1734 carbon controller
Operators Manual
7