Download JK6 Servo Motor - Installation Manual
Transcript
JK6 Servo Motors 2.3 Mechanical Installation Please give heed to the admissible radial and axial forces. For this, please, do also by all means read the chapter 2.2.2 "Avoiding damages", page 18. By all means avoid a hyperstatic arrangement of the motor shaft bearings by using a rigid clutch and an external additional bearing (e.g. in the gearbox). The installation location must be free from conductive and corrosive substances. For encapsulated installation, please consult our application department. Protect the motors against liquids soaking into the bearing in case the shaft end is installed upwards (design V1); refer to Fig. 2. Type IM B 5 (B5) A-Side IM V 1 (V1) IM V 3 (V3) B-Side Fig. 2: Mounting Positions of JK6 Motors Ensure unobstructed ventilation of the JK6 synchronous servo motor and observe the maximum ambient and flange temperatures. The permitted ambient temperature has been specified in chapter 3 "Operating Conditions", page 26. The maximum permitted flange temperature during operation is 65 °C. In order to remove gears, pulleys etc. please use a pulling device according to Fig. 3. Jetter AG 21