Download JK6 Servo Motor - Installation Manual

Transcript
JK6 Servo Motors
2.3 Mechanical Installation
Please give heed to the admissible radial and axial forces. For this,
please, do also by all means read the chapter 2.2.2 "Avoiding
damages", page 18.
By all means avoid a hyperstatic arrangement of the motor shaft
bearings by using a rigid clutch and an external additional bearing (e.g.
in the gearbox).
The installation location must be free from conductive and corrosive
substances.
For encapsulated installation, please consult our application
department.
Protect the motors against liquids soaking into the bearing in case the
shaft end is installed upwards (design V1); refer to Fig. 2.
Type
IM B 5 (B5)
A-Side
IM V 1 (V1)
IM V 3 (V3)
B-Side
Fig. 2: Mounting Positions of JK6 Motors
Ensure unobstructed ventilation of the JK6 synchronous servo motor
and observe the maximum ambient and flange temperatures.
The permitted ambient temperature has been specified in chapter 3
"Operating Conditions", page 26. The maximum permitted flange
temperature during operation is 65 °C.
In order to remove gears, pulleys etc. please use a pulling device
according to Fig. 3.
Jetter AG
21