Download Sartocheck® 3 plus
Transcript
7.2.1 Test Execution Run the test according to the test procedure that you selected and programmed. 7.2.2 – – – – 7.2.3 Switching Off the Device When switching off the unit, proceed as follows: Run through the test to the end. Close the compressed air intake on the compressed air supply. Run the log-off function. Turn off the main switch. Switching off the Device on the Failure of the Power Supply In the event of a power failure, all valves will be switched to a secure state. This guarantees that the filter housing is vented. The ongoing test is cancelled. No test result will be available. Loss of Compressed Air In the event that the compressed air supply stops, the test is automatically cancelled and an error message appears. “Target pressure not reached”. The system is vented automatically. When the supply of compressed air resumes, the unit must be restarted and the test repeated. 7.3 Tests 7.3.1 Test Conditions To obtain reliable and reproducible test results, observe the following: – Run the integrity test at room temperature (approx. 15–30°C), whenever possible. – During an integrity test run, always avoid any temperature changes. – The upstream side of the filter system must be absolutely leak-free (Run pressure hold test). – Do not connect the integrity tester to pressurized systems. – If you wish to use other types of compressed gas and|or wetting fluids not specified by Sartorius Stedim Biotech, consult your local Sartorius Stedim Biotech office or Sartorius Stedim Biotech Technical Support (see Chap. 8.1) – For the Water Intrusion Test, the surface tension of the water must be > 70 dyn/cm. – Always enter correct test parameters. Incorrect test parameters will lead to incorrect test results or erroneous evaluations. Reference Pressure On delivery, the Sartocheck® 3 plus is set to a reference pressure of 1000 mbar. Calibration The integrity tester should be re-calibrated at least once a year, twice being preferable. 22 7.3.2 Test Selection With the Sartocheck® 3 plus, you can directly select a particular integrity test method. This greatly simplifies programming the data for a test, since only the parameters that are relevant for the selected test are displayed. You can select any of the following test methods: Test Methods 1 Diffusion Test 2 Bubble Point Test 3 Diffusion Test and Bubble Point Test (complete test) 4 Water Intrusion Test 5 Water Flow Test 6 Pressure Drop Test 7 Multipoint Diffusion Test 8 Volume Measurement 9 Customer-Specific BP 10 Customer-Specific Multipoint Diffusion Test System Venting At the end of each test, after a power failure or after switching off the unit during a test, the system is automatically vented.