Download COMBIVERT
Transcript
Operation of the Unit CP.21 Rotation change Value Setting Encoder rotation 0 x 1 Options 0 x 2…15 Encoder system 0 x 16 Function no change track exchanged no change reserved no change inverted Description The speed display at CP.1 must be positive when the engine runs manual in clockwise direction. The signals SIN+ and SIN- of the resolver have to be changed, if the sign is wrong. Please ensure that the signals are not short-circuited with the internal shield (see connection resolver). The signals A(+) and A(-) must be changed for units with SIN/COS encoder. Should this involve too much effort then you can achieve a rotation reversal of encoder 1 by means of this parameter. GB - 19