Download FST020 IP65 NEMA 4X
Transcript
Installing/Mounting 2.3 Installing the Sensor 2.3.1 Reflect Mount using Spacer Bar The spacer bar eliminates manual spacing measurements and provides rigidity for mounting the sensors while maintaining axial alignment. Refer to Programming the Flowmeter (Page 22) before proceeding. 1. Perform all required menu steps taking note of the sensor model and size designation. The transmitter then issues the number index and prompts you to press <ENTER> to finish the sensor install routine. Stop at this point. Note Note the number index value displayed in the [Install Xdcr] menu. You will use this index to properly space the sensors. Check to ensure that you have a matched set of sensors. They both should have the same S/N number but marked with either an "A" or "B" (e.g., 19256A and 19256B). 2. Prepare the pipe surface area where the sensors will be mounted. Degrease the surface and remove any grit, corrosion, rust, loose paint, etc. Note Before beginning refer to the Reflect Mount sensor installation diagram below. ① ② ③ ④ Optional: On larger pipes, multiple lengths of straps can be linked together to surround pipe Mounting Strap positioned around Mounting Frame Sensor shown in the 9 o'clock position on pipe Mounting Frame Figure 2-3 ⑤ Space Bar Platform & Clamping Screw ⑥ Space Bar (Front View) ⑦ Metal Post ⑧ Mounting Strap Adjusting Screw Reflect Mount with Mounting Frames and Spacer Bar FST020 IP65 NEMA 4X Operating Instructions, 07/2010, A5E03086489-01 11