Download ba-gemue-566
Transcript
5.2 Technical data – pneumatically operated valve Ambient conditions Control medium Ambient temperature max. 60 °C Operating pressure [bar] 0-6 Inert gases Max. perm. temperature of control medium Control pressure [bar] 70 °C Filling volume: 0.03 dm³ 4.5 - 7 bar All pressures are gauge pressures. Valve bodies are approved up to PN 10. 5.3 Technical data – motorized valve Ambient conditions Protection class Ambient temperature -15 to +55 °C Operating time Electrical data Power supply Power consumption Rating Electrical connection 2 x PG 13.5 2 x round connector (Binder series 717) 5.4 IP 65 acc. to EN 60529 Uv = 24 V 50/60 Hz ± 10 % Uv = 120 V 50/60 Hz ± 10 % Uv = 230 V 50/60 Hz ± 10 % 3.5 VA See actuator version chapter 6.3 approx. 17 or 45 s Input resistance 33 Ω (input protected by reverse diode) Continuously rated Functional module versions AE, AP Functional module versions E1, E2, E3 Kv values Equal-percentage (Code 1) Kv value [l/h] DN 8 DN 10 DN 15 63 100 160 250 400 630 1000 1600 2500 X X X X X X - X X - X Equal-percentage (Code 88) Control characteristic G G G G G G G G G Kv value [l/h] DN 15 DN 20 63 100 160 250 400 630 1000 1600 2500 X X X X X X X X - X Control characteristic L L L L L Kv value [l/h] DN 8 DN 10 DN 15 100 250 630 1600 2500 X X X - X - X Linear (Code 88) Control characteristic L L L L L Kv value [l/h] DN 15 DN 20 100 250 630 1600 2500 X X X X - X 100 80 Kv-Wert [%] Kv value [l/h] Control characteristic G G G G G G G G G Linear (Code 1) 60 L G 40 20 0 20 40 60 Hub [%] Stroke [%] 566 34 / 60 80 100