TROUBLE SHOOTING
Symptom
Fluid discharged from exhaust outlet
Air bubbles in fluid discharge.
Possible Cause

Ruptured Diaphragm (20)

Replace Diaphragm (20)

Diaphragm Nut loose (4A)

Tighten loose Diaphragm Nut (4A)




Motor blows air out main exhaust when stalled
on either stroke.
Low fluid output volume.
Repair

Leak in suction side plumbing
Leak at Inlet Collar (4C)
Leak at Diaphragm Nut (4A)
U-cups inserted incorrectly, damaged, or
missing.
Ceramic valves damaged or contaminated
with debris (7).







Pilot valve not correctly oriented.

Low or blocked incoming air supply.


Outlet plumbing blockage.


Pump not primed.


Suction pipe too small or suction hose not
rigid (kinks or collapses).


Leak in inlet suction plumbing.


Pump blocked internally with debris

10 Check connections of suction plumbing.
Check torque of Inlet Collar (4C)
Check torque of Diaphragm Nut (4A)
Check (2B & 2D) U-cups on major valve
spool.
Check (7) ceramic valves for debris or
damage.
Be certain to load the pilot valve in the
proper orientation per diagram found within
the center-body.
Check air supply.
Check for any obstruction in the outlet
plumbing.
The pump must be mounted vertically for
checks to properly work.
Check for pump cavitation - the suction pipe
should be sized at least as large as the inlet
thread diameter. The suction hose must be
rigid or non-collapsible.
Check all inlet plumbing for possible suction
leaks.
Inspect the pump for debris that could block
internal flow or foul checks.