TROUBLE SHOOTING Symptom Fluid discharged from exhaust outlet Air bubbles in fluid discharge. Possible Cause Ruptured Diaphragm (20) Replace Diaphragm (20) Diaphragm Nut loose (4A) Tighten loose Diaphragm Nut (4A) Motor blows air out main exhaust when stalled on either stroke. Low fluid output volume. Repair Leak in suction side plumbing Leak at Inlet Collar (4C) Leak at Diaphragm Nut (4A) U-cups inserted incorrectly, damaged, or missing. Ceramic valves damaged or contaminated with debris (7). Pilot valve not correctly oriented. Low or blocked incoming air supply. Outlet plumbing blockage. Pump not primed. Suction pipe too small or suction hose not rigid (kinks or collapses). Leak in inlet suction plumbing. Pump blocked internally with debris 10 Check connections of suction plumbing. Check torque of Inlet Collar (4C) Check torque of Diaphragm Nut (4A) Check (2B & 2D) U-cups on major valve spool. Check (7) ceramic valves for debris or damage. Be certain to load the pilot valve in the proper orientation per diagram found within the center-body. Check air supply. Check for any obstruction in the outlet plumbing. The pump must be mounted vertically for checks to properly work. Check for pump cavitation - the suction pipe should be sized at least as large as the inlet thread diameter. The suction hose must be rigid or non-collapsible. Check all inlet plumbing for possible suction leaks. Inspect the pump for debris that could block internal flow or foul checks.