Download Drucksensor Pressure sensor SDE1-
Transcript
SDE1-… Mechanical/pneumatic (...-MS4/MS6) The SDE1-... can be adapted to the following MS-series units: – DE, DL, EE, EM, FRM, LFR, LR, LRB SDE1-G2-MS.. (using SDE1-G2-MS4 as an example) 1) a) Install the adapter b) Install the SDE1 2) The adapter has two small spigots on its rear side for pressure connection. 1. Make sure that either the spigot (a) or the corresponding hole (b) on the unit is fitted with an O-ring for sealing. 2. Check that the O-rings are firmly in place and remove any unnecessary O-rings. 3. To mount the unit, push the mounting screws (connected to the mounting brackets) outwards and tighten to 0.5 Nm 3) 1. Check that the moulded seal (c) on the front side of the adapter is firmly in place. 2. Make sure the sealing surfaces between the SDE1-... and the adapter are clean. 3. To mount, insert the SDE1-... into the adapter, press on it and tighten mounting screw (d) to 1.0 Nm. a c b d 1) There are slight differences in form and dimensions between the adapters for MS4 and MS6. The mounting procedure is the same for both. 2) The SDE1-... can also be rotated 180° before mounting. 3) Using a Torx screwdriver – size T10 Fig. 7 42 Festo SDE1-…-D2 1301g English