Download Adaptec Serial ATA RAID 1210SA User`s Guide
Transcript
ãŠãŒã¶ãŒãº ã¬ã€ã ADAPTEC SERIAL ATA RAID 1210SA Adaptec Serial ATA RAID 1210SA ãŠãŒã¶ãŒãº ã¬ã€ã R èäœæš© © 2003 Adaptec, Inc. All rights reserved. ãã®ææžã¯ãããšããã®äžéšã§ãã£ãŠãäº åã« Adaptec,Inc., 691 South Milpitas Blvd., Milpitas CA 95035 ããæžé¢ã«ããèš±å¯ ãåŸãå Žåãé€ããé»åçãæ©æ¢°çãè€åæ©ãèšé²ãããã¯ãã®ä»ãããªãææ®µã ãããªã圢åŒã«ãã£ãŠã転éãè€è£œãæ€çŽ¢ã·ã¹ãã ã«ç»é²ããŠã¯ãªããŸããã åæš Adaptec ãAdaptec Storage ManagerãHostRAID ããã³ Adaptec ã®ã㎠㯠Adaptec, Inc. ã®ç»é²åæšã§æ°ã¶åœã§ç»é²ãããŠããŸãã Windows 2000 ããã³ Windows XP 㯠Microsoft 瀟ã®ç»é²åæšã§ãããã¢ã¡ãªã«ã ã®ä»ã®è«žåœã§ã©ã€ã»ã³ã¹ã®äžã«äœ¿çšãããŠããŸãã ãã®ä»ã®åæšã¯åæš©å©ææè ã®ææã«ãããã®ã§ãã å€æŽ æ¬ææžã®è³æã¯åãªãæ å ±ãšããŠæäŸããããã®ã§ãããäºåãªã倿Žãããå¯ èœæ§ããããŸããæ¬æžã®å¶äœã«éãæ£ç¢ºããæããããã«äžå šã®æ³šæãæã£ãŠã¯ ãããŸãããæ¬æžäžã®èª€èšãæ å ±ã®æãããããã¯æ å ±ã®äœ¿çšã«èµ·å ããçµæã« é¢ã㊠Adaptec 瀟ã¯ãããªã責任ãè² ããŸããã Adaptec 瀟ã¯ããŠãŒã¶ã«å¯Ÿããäºåã®çŽæåã³åç¥ç¡ãã«è£œåã®ãã¶ã€ã³ã倿Žã ãæš©å©ãçä¿ããŸãã çŠæ¢äºé æ¬æžã®ã©ã®éšåããèäœæš©è ããã®äºåã®æžé¢ã«ããèš±å¯ãªãããŠãé»åçãæ© 械çãåãããè€åãèšé²ãªã©ãããªãæ¹æ³ããããªã圢ã«ãã転éãè€è£œãæ€ çŽ¢ã·ã¹ãã ãžã®ç»é²ãè¡ãäºã¯æ³åŸã§çŠæ¢ãããŠããŸãã ii ã¢ããããã¯ãã¯ãã«ã«ãµããŒã ã¢ããããã¯ã®è£œåã¯ãç°¡åã«ã€ã³ã¹ããŒã«ããŠäœ¿ããããã«ç¹å¥ã«éçºãã㟠ãããç»é¢ã«è¡šç€ºãããæç€ºããã«ããããã¥ã¢ã«ã®å¶äœã«ããã£ãŠã¯ãããã æãã䜿ãæããã®ãšãªãããååé æ ®ããŠãããŸãããã以äžã®æ å ±ãå¿ èŠãª å Žåã¯ãã¢ããããã¯ç€Ÿã®ãã¯ãã«ã«ãµããŒããžãé£çµ¡ãã ããã â é»è©±ãã¯ãã«ã«ãµããŒãïŒ03-5308-6120 ïŒå仿é å¹³æ¥åå 9 æ -12 æãååŸ 1 æ -6 æ åãæ¥ãç¥ãç¥æ¥ãé€ãïŒ ã¢ããããã¯ãã¯ãã«ã«ãµããŒããžãé£çµ¡ããããšãã¯ãå¿ ã以äžã®æ å ±ããçš æãã ããã â ã¢ããããã¯ããŒããŠã§ã¢è£œåã®ã¢ãã«åã³ TSID çªå· æ¬è£œåã«äžå³ã®ãããªã補åçªå·ãã·ãªã¢ã«çªå·ãTSIDïŒãã¯ãã«ã«ãµããŒã ID çªå·ïŒãå°å·ãããŠããã·ãŒã«ã忢±ãããŠããŸããä¿èšŒæžã«è²Œä»ããŠå€§å ã«ä¿ç®¡ã®äžããã¯ãã«ã«ãµããŒããžã®ãååãã®éã«å¿ ããé£çµ¡ãã ããã â ã¢ããããã¯ãœãããŠã§ã¢è£œåã®ååãšããŒãžã§ã³çªå· â ã䜿ãã«ãªã£ãŠãã OS ã®çš®é¡ãšããŒãžã§ã³çªå·ïŒäŸïŒWindows XPïŒ â ã¢ããããã¯è£œåãè³Œå ¥ããã販売åºå Adaptec Serial ATA RAID 1210SA ããããããã³ã³ãã¥ãŒã¿ã·ã¹ãã ã«å èµã ããŠãããã®ã§ããå Žåããããã¯åšèŸºæ©åšçã«å梱ãããŠããå Žåã«ã¯ã㟠ãããã®ã³ã³ãã¥ãŒã¿ã¡ãŒã«ã«é£çµ¡ããæè¡ãµãŒãã¹ããåããã ãããæ¥æ¬ ä»¥å€ã®åœã§ã¯ãããããã®åœã®æ£èŠ Adaptec 販売åºã«ãé£çµ¡ãã ããã ã¢ããããã¯ãžã£ãã³ ã€ã³ã¿ãŒãããããŒã ããŒãž â http://www.adaptec.co.jp iii æ³èŠé©åã¹ããŒãã¡ã³ã FCCïŒç±³åœé£éŠéä¿¡å§å¡äŒïŒç¡ç·åšæ³¢æ°åŠšå®³æ³æºæ èŠåïŒæ¬è£ 眮ã«å¯Ÿããæºæ ã®è²¬ä»»ãããåœäºè ããç¹å¥ã«èªå¯ãªããå å·¥ãŸãã¯å€æŽãå ãã ããå Žåãæ¬è£ çœ®ã䜿çšãããŠãŒã¶ã®æš©éã¯ç¡å¹ã«ãªãå¯èœæ§ããããŸãã æ¬è£ 眮ã¯ãæ€æ»ã®çµæãFCC åããŒã 15 ã«åŸãã¯ã©ã¹ B ããžã¿ã«è£ 眮ã®å¶éã«æºæ ããŠã㟠ãããããã®å¶éã¯ãäœå® å°åã«ãããŠæäœããéã劚害ããã®ä¿è·ãç®çãšãããã®ã§ãã æ¬è£ 眮ã¯ãç¡ç·åšæ³¢æ°ãçºçã䜿çšãŸãæŸå°ããå ŽåããããŸããåæ±èª¬ææžã«åŸã£ãŠèšçœ®ãŸ ãã¯äœ¿çšãããªãå Žåãç¡ç·éä¿¡ã«æå®³ãªåŠšå®³ãåŒãèµ·ããå¯èœæ§ããããŸãããŸããèšçœ®ç¶ æ³ã«é¢ãããé害ãåŒãèµ·ããå¯èœæ§ããããŸããæ¬è£ çœ®ãããã¬ããã©ãžãªçã®åä¿¡é害㮠åå ãšãªã£ãŠãããã©ããã¯ãè£ çœ®ã®é»æºã® ON/OFF ãåãæ¿ããããšã§ã確èªé ããŸãã æ¬è£ 眮ãåä¿¡é害ã®åå ã§ãããšèããããå Žåã¯ä»¥äžã®æé ã®ããããããŸãã¯å¹Ÿã€ãçµã¿ åãããŠã詊ããã ããã â ãã¬ããŸãã¯ã©ãžãªã®ã¢ã³ããã®åããå€ãããããŸãã¯å Žæãå€ããã â ãã¬ããŸãã¯ã©ãžãªãšæ¬è£ 眮ã®éã®è·é¢ãé¢ãã â ãã¬ããŸãã¯ã©ãžãªãšã¯å¥ã®åè·¯ã«ããã³ã³ã»ã³ãã«è£ çœ®ãæ¥ç¶ããã â 販売åºãŸãã¯ãã¬ããã©ãžãªã®ä¿®çæ¥è ã«ãçžè«ãã ããã â æ³èŠäžã®å¶éã«æºæ ãã䜿çšãè¡ãã«ã¯å質ã®è¯ãI/Oã±ãŒãã«ã黿ºã±ãŒãã«ãã䜿çšãã ããã æ¬è£ 眮ã¯ãFCC èŠåããŒã 15 ã«æºæ ããŠããããã®äœ¿çšã¯ã次㮠2 ã€ã®æ¡ä»¶ã«åŸããŸãïŒïŒ1ïŒ æ¬è£ 眮ã¯ã劚害ãåŒãèµ·ãããªããšæ³å®ããããïŒ2ïŒæ¬è£ 眮ã¯ãäžé©åãªæäœã«èµ·å ããé害 ãå«ããããªãéå®³ãæ¿èªããªããã°ãªããªãã Adaptec, Inc. AAR-1210SA Tested to Comply With FCC Standards FOR HOME OR OFFICE USE EU æ³æºæ æ¬è£œåã¯ãã¹ãã®çµæä»¥äžã®ãšãŒãããã®åºæºã«æºæ ããŠããŸãã EMC Directive 89/336/EEC, (92/31/EEC ããã³ 93/68/EEC ã«æ¹æ£ïŒ â EN55022 (1998) Emissions â EN55024 (1998) Immunity: â â â â â â EN61000-4-2 (1998) Electrostatic discharge:±4 kV contact, ±8 kV air EN61000-4-3 (1998) Radiated immunity EN61000-4-4 (1995) Electrical fast transients/burst:±1 kV AC, ±0.5 kV I/O EN61000-4-5 (1995) Surges ±1 kV differential mode, ±2 kV common mode EN61000-4-6 (1996) Conducted immunity:3 V EN61000-4-11 (1994) Supply dips and variation:30% and 100% ããã«ãU.L. ãèŠæ±ãããæ©åšã«ã€ããŠã¯ãEN60950 with amendments A1, A2, A3, A4, A11. ã«ããã°ã以äžã«é©åããŠããŸãã EMC Directive 73/23/EEC ïŒ93/68/EEC ã«æ¹æ£ïŒ ãªãŒã¹ãã©ãªã¢ããã¥ãŒãžãŒã©ã³ãæ³æºæ æ¬è£ 眮㯠Spectram Management Agency ãçå®ãããªãŒã¹ãã©ãªã¢ / ãã¥ãŒãžãŒã© ã³ãæšæº AS/NZS 3548 ã«åŸã£ããã¹ãã®çµæã¯ã©ã¹ B ããžã¿ã«è£ 眮ã®å¶éã«æºæ ã ãŠããŸãã iv ã«ããæ³æºæ æ¬è£œåã¯ã¯ã©ã¹ B ããžã¿ã«è£ 眮ã§ããæ¬è£œåã¯ãã«ãã黿³¢åŠšå®³è£ çœ®èŠåã®èŠä»¶ã ãã¹ãŠæºãããŠããŸãã æ¥æ¬æ³æºæ ( èªäž»èŠå¶ ) æ å ±åŠçè£ çœ®ç黿³¢é害èªäž»èŠå¶åè°äŒïŒVCCIïŒã®åºæºã«æºæ ããŠããŸãã ãã®è£ 眮ã¯ãæ å ±åŠçè£ çœ®ç黿³¢é害èªäž»èŠå¶åè°äŒïŒVCCIïŒã®åºæºã« åºã¥ãã¯ã©ã¹ B æ å ±æè¡è£ 眮ã§ãããã®è£ 眮ã¯ãå®¶åºç°å¢ã§äœ¿çšããããš ãç®çãšããŸããããã®è£ 眮ãã©ãžãªããã¬ããžã§ã³åä¿¡æ©ã«è¿æ¥ããŠäœ¿ çšãããšãåä¿¡é害ãåŒãèµ·ããããšããããŸããåæ±ãèª¬ææžã«åŸã£ ãŠãæ£ããåæ±ããããŠäžããã v ç®æ¬¡ 1 ã¯ããã« ã¯ããã«ãèªã¿ãã ãã .................................. 1-1 ã·ã¹ãã èŠä»¶ ............................................ 1-2 ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã®äºææ§ ................... 1-2 èšæ¶å®¹éèŠä»¶ ........................................ 1-2 ãã¶ãŒããŒãã®äºææ§ ................................ 1-2 ããã€ã¹ã®äºææ§ .................................... 1-2 ãããã®å 容 ............................................ 1-3 Adaptec 1210SA ã³ã³ãããŒã© ......................... 1-3 ããã¥ã¡ã³ãã«ã€ã㊠.................................... 1-4 Adobe Acrobat Reader ã®ã€ã³ã¹ããŒã« .................. 1-4 ã³ã³ãããŒã©ã®æ©èœ ...................................... 1-5 ã€ã³ã¹ããŒã«æé ã®æŠèŠ .................................. 1-6 ã¹ãã¬ãŒãžç®¡çãœãããŠã§ã¢ã®æŠèŠ ........................ 1-7 å®å šäžã®ã泚æ .......................................... 1-8 ã¡ã¢ããæ³šæ ........................................ 1-8 é黿° .............................................. 1-8 2 ã³ã³ãããŒã©ã®åãä»ã æŠèŠ .................................................... 2-1 ã³ã³ãããŒã©ã®åãä»ã .................................. 2-2 ã³ã³ãããŒã©ãšããã€ã¹ã®ãã§ã㯠........................ 2-3 èµ·åã³ã³ãããŒã©ã®æ±ºå® .................................. 2-4 3 ãã©ã€ãã®ã€ã³ã¹ããŒã« æ°ãã Windows ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã«....... 3-1 æ¢åã® Windows ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã«....... 3-4 Red Hat Linux 7.3 ãŸã㯠8.0 ã®ã€ã³ã¹ããŒã« ................ 3-7 æ¢åã® Linux ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã« ãŸãã¯ã¢ããããŒã ............................... 3-9 SuSE Linux 8.0 ãŸã㯠8.1 ã®ã€ã³ã¹ããŒã« .................. 3-9 æ°ãã Linux ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã«...... 3-9 æ¢åã® Linux ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã« ãŸãã¯ã¢ããããŒã .............................. 3-12 vi Contents 4 Adaptec Storage ManagerâBrowser Edition ã® ã€ã³ã¹ããŒã« æŠèŠ .................................................... 4-1 ãµããŒããããã©ãŠã¶ .................................... 4-2 ã«ã¹ã¿ã åã³ ã³ã³ãã¯ã ã€ã³ã¹ããŒã« .................... 4-2 Adaptec Storage Manager Browser Edition ã® Windows ãžã® ã€ã³ã¹ããŒã« ............................................ 4-3 Windows ã® ã€ã³ã¿ãŒããã ãã©ãŠã¶ã®èšå® ............ 4-4 Adaptec Storage Manager Browser Edition ã® Linux ãžã® ã€ã³ã¹ããŒã« ............................................ 4-7 5 Adaptec Storage Managerâ Browser Edition ã® äœ¿çš æŠèŠ .................................................... 5-2 ã¢ãŒããã¯ãã£ã®æŠèŠ .................................... 5-3 ãã° ã€ã³ ............................................... 5-4 ã»ãã¥ãªãã£èªèšŒã®äœæ .................................. 5-5 ãŠãŒã¶ç»é² .............................................. 5-6 åºæ¬äºé ................................................ 5-7 ãããã¢ãã ããŒã« ãã³ã ........................... 5-8 ç©çããã€ã¹ ........................................ 5-8 è«çããã€ã¹ ....................................... 5-10 ã¢ã¬ã€ã®äœæ ........................................... 5-12 詳现èšå® ........................................... 5-13 ã¢ã¬ã€ã®åé€ ........................................... 5-15 ã¢ã¬ã€ã®å€æŽ ........................................... 5-16 ãŠãŒã¶ ã€ã³ã¿ãŒãã§ã€ã¹ ãªãã·ã§ã³ ...................... 5-17 ã€ãã³ãã®è¡šç€º ......................................... 5-18 ã€ãã³ããã¥ãŒã¢ ................................... 5-18 ã€ãã³ãéç¥ ....................................... 5-18 ãã«ãã®äœ¿çš ........................................... 5-20 ããããã£ã®è¡šç€ºãšå€æŽ ................................. 5-20 ã³ã³ãããŒã©ã®ãããã㣠........................... 5-20 ãã£ãã«ãšããŒãã®ãããã㣠....................... 5-21 ç©çããã€ã¹ã®ãããã㣠........................... 5-22 ãšã³ã¯ããŒãžã£ã®ãããã㣠......................... 5-24 è«çããã€ã¹ã®ãããã㣠........................... 5-25 ã¿ã¹ã¯ã®è¡šç€ºãšäœæ ..................................... 5-26 ã¿ã¹ã¯ãã¥ãŒã¢ ..................................... 5-26 æ°ããã¿ã¹ã¯ ....................................... 5-26 vii Contents A BIOS ãŠãŒãã£ãªã㣠ARC ãšã¯äœã .......................................... A-1 ACU ã®äœ¿çš ............................................ A-2 ã¢ã¬ã€ã®ç®¡ç ....................................... A-2 ã¢ã¬ã€ã®äœæ ....................................... A-3 ãã£ã¹ã¯ ãã©ã€ãã®åæå .......................... A-6 SATASelect ã®äœ¿çš ...................................... A-7 SATASelect ã®èµ·åãšçµäº............................ A-7 SATASelect ã¡ãã¥ãŒã®äœ¿çš.......................... A-7 CCU ã®äœ¿çš ............................................ A-7 SATA Configuration Utility ã®äœ¿çš ........................ A-9 Disk Utilities ã®äœ¿çš .................................... A-10 B ãµããŒããããŠãã RAID ã¿ã€ã RAID 0 .....................................................................................B-2 RAID 1 .....................................................................................B-2 C 仿§ çšèªé viii 1 ã¯ããã« ãã®ç« ã®æŠèŠ ã¯ããã«ãèªã¿ãã ãã 1-1 ã·ã¹ãã èŠä»¶ 1-2 ãããã®å 容 1-3 ããã¥ã¡ã³ãã«ã€ã㊠1-4 ã³ã³ãããŒã©ã®æ©èœ 1-5 ã€ã³ã¹ããŒã«æé ã®æŠèŠ 1-6 ã¹ãã¬ãŒãžç®¡çãœãããŠã§ã¢ã®æŠèŠ 1-7 å®å šäžã®ã泚æ 1-8 ã¯ããã«ãèªã¿ãã ãã Adaptec Serial ATA RAID 1210SA ã³ã³ãããŒã©ãåãä»ããå ã«ãæ¬ç« ããèªã¿ãã ããããã®ç« ã§ã¯ãæ¬æžãèªãããã®ã〠ã³ãã瀺ããã€ã³ã¹ããŒã« ããã»ã¹ã®æŠèŠã説æããŸãã 1-1 ã¯ããã« ã·ã¹ãã èŠä»¶ ãã®é ã§ã¯ã以äžã®ã·ã¹ãã èŠä»¶ã«ã€ããŠèª¬æããŸãã â ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã®äºææ§ â ãã©ã€ãããã³ãœãããŠã§ã¢ã«å¿ èŠãªèšæ¶å®¹é â ãã¶ãŒããŒãã®äºææ§ â ããã€ã¹ã®äºææ§ ( ã·ãªã¢ã« ATA) ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã®äºææ§ â Microsoft Windows® 2000 ããã³ Windows XP® â Linux â Red Hat 7.3 ããã³ 8.0 â SunSE 8.0 ããã³ 8.1 ã¡ã¢ : ææ°ã® Linux ã®äºææ§ã«é¢ããæ å ±ã«ã€ããŠã¯ã http://www.adaptec.com ããã㯠linux.adaptec.com ãåç §ã ãŠãã ããã èšæ¶å®¹éèŠä»¶ Adaptec Storage Management ãœãããŠã§ã¢ã«ã¯ãçŽ 20 MB ã® ãã£ã¹ã¯ ã¹ããŒã¹ãå¿ èŠã§ãã ãã¶ãŒããŒãã®äºææ§ ã³ã³ãããŒã©ã¯ããŠãããŒãµã« PCI ã«ã€ã³ã¹ããŒã«ãããã®ã§ã ãã¶ãŒããŒããš BIOS ã以äžã®èŠä»¶ãæºãããŠããå¿ èŠããã㟠ãã â PCI ããŒã«ã« ãã¹èŠæ Œ ãªããžã§ã³ 2.2 ã«æºæ ããŠããããšã â ã¡ã¢ãª ãããããã倧ããªã¢ãã¬ã¹é åãæäŸããããšã ããã€ã¹ã®äºææ§ Adaptec 1210SA ã¯ããã®ãããã«å梱ããã 2 æ¬ã®ã·ãªã¢ã« ATA ã±ãŒãã«ã䜿ã£ãŠã2 å°ãŸã§ã®ã·ãªã¢ã« ATA ããŒããã£ã¹ã¯ ãã©ã€ãã®ã¿ããµããŒãããŸãã 1-2 ã¯ããã« ãããã®å 容 Adaptec ã³ã³ãããŒã© ãããã«ã¯ã次ã®ãã®ãå«ãŸããŠããŸãã â â Adaptec 1210SA ã³ã³ãããŒã© ( äžå³åç § ) ãAdaptec Serial ATA RAID 1210SA ã¯ã£ã㯠ã€ã³ã¹ããŒã« ã¬ã€ ãã â ã€ã³ã¹ããŒã« CD â ããŒãããã¡ã€ã« ãã©ã±ãã â Serial ATA ã€ã³ã¿ãŒãã§ã€ã¹ ã±ãŒãã« 2 æ¬ â ä¿èšŒã«ãŒã â TSID ( ãã¯ãã«ã«ãµããŒã ID) ã©ãã« ( 詳现㯠iii ããŒãž åç §ïŒ â ãŠãŒã¶ç»é²ã¯ãã Adaptec 1210SA ã³ã³ãããŒã© Adaptec 1210SA ã³ã³ãããŒã©ã¯ã以äžã®ãããªå€èгãããŠã㟠ããã·ãªã¢ã« ATA ã€ã³ã¿ãŒãã§ãŒã¹ã³ãã¯ã¿ã®äœçœ®ã¯ãã·ãªã¢ã« ATA ããŒããã©ã€ããæ¥ç¶ããã®ã«å¿ èŠãªã®ã§ã泚æãã ããã SATA ãã©ã€ã 1 ã®ã³ãã¯ã¿ SATA ãã©ã€ã 0 ã®ã³ãã¯ã¿ 1-3 ã¯ããã« ããã¥ã¡ã³ãã«ã€ã㊠ãã®ãããã«å梱ãããããã¥ã¡ã³ãé¡ã¯ã以äžã®ããã«ãªã㟠ãã â ãAdaptec Serial ATA RAID 1210SA ã¯ã£ã㯠ã€ã³ã¹ããŒã« ã¬ã€ ããâ ãã®å°å·ç©ã«ã¯ãã³ã³ãããŒã©ãã€ã³ã¹ããŒã«ãããã ã«å¿ èŠãªæ å ±ã®æ®ã©ãå«ãŸããŸãã â ãAdaptec Serial ATA RAID 1210SA ãŠãŒã¶ãŒãº ã¬ã€ã ã( æ¬æž ) â ãªãªãŒã¹ ããŒã â ã€ã³ã¹ããŒã«ãéå§ããåã«ãAdaptec ã³ ã³ãããŒã©ããœãããŠã§ã¢ãããã¥ã¡ã³ãé¡ã«é¢ãããªãªãŒã¹ ããŒããã芧ã«ãã ããããããã®æ å ±ãåç §ããã«ã¯ãã ãã¥ã¡ã³ãã®è¡šç€ºã®ãªã¹ããã ãªãªãŒã¹ ããŒã ãéžæãã ããCD ã®ã«ãŒã ãã£ã¬ã¯ããªã«ãã ãReadmeããã¡ã€ã«ã ããã¹ã ãšãã£ã¿ã§éããŸããææ°ã®æ å ±ã«ã€ããŠã¯ã http://www.adaptec.co.jp ãŸã㯠http://www.adaptec.com ãåç § ããŠãã ããã ãŸããããã¥ã¡ã³ãé¡ã http://www.adaptec.co.jp ãŸã㯠http://www.adaptec.com ãããå©çšå¯èœã§ããã¢ããããã¯ã® Web ãµã€ãããå ¥æã§ããããã¥ã¡ã³ãã¯ãCD ã«åé²ãããŠã ããã®ãããæ°ããå ŽåããããŸããã¬ã€ãã®è£é¢ã«ããã㌠ãžã§ã³çªå·ã確èªããŠãã ããã Adobe Acrobat Reader ã®ã€ã³ã¹ããŒã« Adaptec ã€ã³ã¹ããŒã« CD ã«ã¯ãAdobe Acrobat Reader ã® Windows ãš Linux ã®ããããã®ããŒãžã§ã³ãå«ãŸããŠããŸãã㟠ããAdobe Acrobat Reader 㯠http://www.adobe.co.jp ããç¡æã§ ããŠã³ããŒãããããšãã§ããŸããïŒAdaptec ã€ã³ã¹ããŒã« CD ã« å«ãŸããããAdaptec Serial ATA RAID 1210SA ãŠãŒã¶ãŒãº ã¬ã€ãã ã®ãã㪠PDF (Portable Document Format) ãã©ãŒãããã®ãã㥠ã¡ã³ããèŠãã«ã¯ãReader ãå¿ èŠã«ãªããŸãã Reader ãã€ã³ã¹ããŒã«ããã«ã¯ã以äžã®æé ã«åŸããŸãã â WindowsâAdaptec ã€ã³ã¹ããŒã« CD ãæ¿å ¥ããèªååçã åŸ ã¡ãŸããCD ãèªåçã«éå§ããªããã°ãCD ã®ã«ãŒããå ç §ããautorun ãã¯ãªãã¯ããŸãããããããå¿ èŠãªãªãã·ã§ ã³ãéžæããŸãã 1-4 ã¯ããã« â Linuxâ <CD Mount Point>/packages/Acrobat_Reader/Linux ãåç § ããŸãããã®å Žæãåç §ããã«ã¯ããã« ãã¹ãæå®ããŠãã ããããã« ãã¹ãæå®ããªããšããã®å Žæãéžæã§ããªãã ãšããããŸãã ã³ã³ãããŒã©ã®æ©èœ Adaptec 1210SA ã¯ã以äžã®æ©èœããµããŒãããŠããŸãã â Adaptec ã® HostRAID ï ãã¯ãããžã䜿ã£ã RAID ã¬ãã« 0ã 1 åã³ã·ã³ãã« ããªã¥ãŒã â PCI ããŒã«ã« ãã¹èŠæ Œ ( ãªããžã§ã³ 2.2ãPCI ã¯ããã¯é床 66 MHz ãŸã§ ) â ARC (Advanced RAID Configuration) ã«ããããªãã¬ãŒãã£ã³ ã°ã«äŸåããªã RAID ã®äœæãšç®¡ç â Adaptec Storage Managerï â Browser Edition ãçšãããç°¡å ãªã¢ã¬ã€æ§ç¯åã³èšå® â ã³ã³ãããŒã©ã® BIOS ããã³ ARC ã®ã¢ããã°ã¬ãŒãã容æã« ãããã©ãã·ã¥ ROM â è±æ°åããŒãžã£åãã®ã¡ãã»ãŒãžã³ã°ãå«ããã€ãã³ã ãã® ã³ã°ããã³ãããŒããã£ã¹ã 1-5 ã¯ããã« ã€ã³ã¹ããŒã«æé ã®æŠèŠ ã³ã³ãããŒã©ãåãä»ããæ¥ç¶ããèšå®ããæé ã以äžã«ç°¡å㫠説æããŸãã 1 ãã®ç« ã®èšèŒäºé ãããèªã¿ãçè§£ããŸãã 2 第 2 ç« ã®ã ã³ã³ãããŒã©ã®åãä»ããã«èšèŒãããŠããæé ã« åŸããã³ã³ãããŒã©ãšããŒããã£ã¹ã¯ ãã©ã€ããåãä»ã㊠èšå®ããŸãã 3 第 3 ç« ã®ã ãã©ã€ãã®ã€ã³ã¹ããŒã«ãã§ã¯ãã䜿ãã®ã·ã¹ãã ã«å¿ èŠãªæé ãã説æããŸãã æ°ããã·ã¹ãã ã®å Žå a ã¢ã¬ã€ãæ§ç¯ããŸãã b ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã€ã³ã¹ããŒã«äœæ¥ã®å§ãã«ãã³ ã³ãããŒã©ã®ãã©ã€ããã€ã³ã¹ããŒã«ããŸãã æ¢åã®ã·ã¹ãã ã®å Žå a ã³ã³ãããŒã© ãã©ã€ããã€ã³ã¹ããŒã«ããŸãã b ã¢ã¬ã€ãæ§ç¯ããŸãã ã¡ã¢ : ææ°ã®ãã©ã€ãã®ããŠã³ããŒãã«ã€ããŠã¯ã www.adaptec.com ãŸã㯠www.adaptec.co.jp ãåç §ããŠãã ããã 4 Adaptec Storage Manager â Browser Edition ãã€ã³ã¹ããŒã«ã ãŸãã詳现ã¯ã第 4 ç« ã®ã Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã«ããåç §ããŠäžããã 5 http://www.adaptec.co.jp/support/regist.html ã«ã¢ã¯ã»ã¹ããŠã ã䜿ãã®ã³ã³ãããŒã©ã®ãŠãŒã¶ç»é²ãè¡ã£ãŠãã ããã 1-6 ã¯ããã« ã¹ãã¬ãŒãžç®¡çãœãããŠã§ã¢ã®æŠèŠ Adaptec 1210SA ã«ã¯ãã¹ãã¬ãŒãž ãµãã·ã¹ãã ã管çãããã ã®æ¬¡ã®ãœãããŠã§ã¢ãä»å±ããŠããŸãã â Adaptec Storage Manager-Browser Editionâãã©ãŠã¶ ããŒã¹ã® ã¹ãã¬ãŒãžç®¡çãœãããŠã§ã¢ã§ãã¢ã¬ã€ã®äœæã管çãã¢ã¬ã€ ã®ç®¡çã«å¿ èŠãªããŒã¿ ãã°äœææ©èœã®ãã¹ãŠãæäŸããŠã㟠ããã¢ã¬ã€ã¯ã次ã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã䜿çšããã· ã¹ãã äžã§èšå®ããã³ç®¡çã§ããŸãã â Windows 2000 ããã³ Windows XP â Red Hat Linux 7.3 ããã³ 8.0 â SuSE Linux 8.1 ããã³ 8.0 詳现ã€ããŠã¯ã4 ç« åã³ 5 ç« ãåç §ããŠãã ããã â ARC(Adaptec RAID Configuration)â ã³ã³ãããŒã©ã«çµã¿èŸŒ ãŸãã BIOS ã³ãŒãã®äžéšã§ããBIOS ã®èµ·åäžã« Ctrl+A ãæŒ ããšãARC ãèµ·åã§ããŸãã詳现ã€ããŠã¯ãä»é² A ã®ãBIOS ãŠãŒãã£ãªãã£ããåç §ããŠãã ããã â ACU (Array Configuration Utility)â ã¢ã¬ã€ã®äœæãæ§æã管 çã®ããã«äœ¿çšãã DOS ã¢ããªã±ãŒã·ã§ã³ã§ãã詳现ã€ã㊠ã¯ãä»é² A ã®ãBIOS ãŠãŒãã£ãªãã£ããåç §ããŠãã ããã 1-7 ã¯ããã« å®å šäžã®ã泚æ ãèªèº«ã®å®å šãšãã䜿ãã®æ©åšã®å®å šã®ããã«ã以äžã®äºé ãã å®ããã ããã â äœæ¥å Žæãšã³ã³ãã¥ãŒã¿ãæŽç¶ãšããç°å¢ã«ä¿ã¡ãäžèŠãªãã® ãåšå²ã«çœ®ããªãããã«ããŸãã â ã³ã³ãã¥ãŒã¿æ¬äœã®ã«ããŒãéããåã«ã¯ã黿ºã³ãŒããã³ã³ ã»ã³ãããæããŸãã ã¡ã¢ããæ³šæ ãã®ããŠãŒã¶ãŒãº ã¬ã€ããã§ã¯ã以äžã«ç€ºããããªãã¡ã¢ããæ³š æã䜿çšããŠéèŠæ å ±ã匷調ããŸãã ã¡ã¢ : ç¡èŠããŠãè² å·ããè³ç£ã®æå®³ãããŒã¿æå€±ã®å¿é ã ãªã éèŠæ å ±ã匷調ããŸãã ! ãæ³šæ : ç¡èŠãããšè£ çœ®ã®æ éãããŒã¿æå€±ãåŒãèµ·ããå¯ èœæ§ãããéèŠæ å ±ã匷調ããŸãã é黿° é黿° (ESD) ã¯äººéã®æ¥åžžçãªæŽ»åã«ä»ãç©ã§ããESD ã¯ãé»è· ãèç©ãä¿æããç©è³ªã«ãã£ãŠäœããããã®é»è·ã¯æ¥è§Šããããš ã§äººéãŸãã¯ä»ã®ç©è³ªã«ç§»åããŸãã ! ãæ³šæ : é»åéšåã®åãæ±ãã誀ããšãESD ã«ããæå·ãå ããéšåã®å®å šãŸãã¯æç¶çãªæ éã«ã€ãªããããšããã㟠ããã³ã³ããŒãã³ããåãå€ããã亀æããããããšãã¯ã å¿ ã ESD äºé²æé ã«åŸã£ãŠãã ããã ESD ã«ããæå·ã鲿¢ããã«ã¯ä»¥äžã®ç¹ã«æ³šæããŠãã ããã â æéŠãŸãã¯è¶³éŠã«åž¯é»é²æ¢ã¹ãã©ãããå¿ ãè£ çããèã«å¯ç ãããŸããã¹ãã©ããã®è£ 眮åŽã®ç«¯ããå¡è£ ãããŠããªãéå± ã·ã£ãŒã·ã®è¡šé¢ã«æ¥ç¶ããŸãã垯é»é²æ¢ã¹ãã©ããããªãå Žå ã«ã¯ãã³ã³ãããŒã©ããã³ã³ãã¥ãŒã¿ã®éšåãæ±ãåã«ãéå± ã±ãŒã¹ã«è§ŠããŠäœå ã®é黿°ãæŸåºãããŸãã 1-8 ã¯ããã« â æã®äžããã³ã³ãããŒã©ãè§Šãã®ã¯ãããŠãã ããã垯é»é²æ¢ ã¹ãã©ããã¯ãã³ã³ããŒãã³ããäœå ã«ããé黿°ããä¿è·ã ãã ãã§ããè¡£é¡ã«ã€ããé黿°ããŸããæå·ãèµ·ããåå ãš ãªãå¯èœæ§ããããŸãã â ã³ã³ãããŒã©ã¯ããã©ã±ããã端ã®ã¿ãæã€ããã«ããŠãã ã ããããªã³ãåè·¯åºæ¿ãã³ãã¯ã¿ã«ã¯æãè§Šããªãããã«ã㟠ãã â ã³ã³ãããŒã©ãåãå€ããéã¯ããããã«å梱ããè¢ã®ãã㫠垯é»é²æ¢å å·¥ã«ãªã£ãŠãããã®ãã䜿çšãã ããã â ã³ã³ãããŒã©ããAdaptec ã«è¿éããéã«ã¯ãããã«åž¯é»é²æ¢ çšããã°å ¥ããŠãã ããã 1-9 2 ã³ã³ãããŒã©ã®åãä»ã ãã®ç« ã®æŠèŠ æŠèŠ 2-1 ã³ã³ãããŒã©ã®åãä»ã 2-2 ã³ã³ãããŒã©ãšããã€ã¹ã®ãã§ã㯠2-3 èµ·åã³ã³ãããŒã©ã®æ±ºå® 2-4 æŠèŠ ã³ã³ãããŒã©ããã³ãã©ã€ããåãä»ããã«ã¯ã以äžã®ãã®ãã ããã 1 ã€ãŸã㯠2 ã€ãå¿ èŠã§ãã â Serial ATA ããŒããã£ã¹ã¯ ãã©ã€ã â ã·ãªã¢ã« ATA ã±ãŒãã« ( ãããã«åæ¢±ïŒ ã·ãªã¢ã« ATA ããã€ã¹ã®èšå®ã¯ã以äžã®çç±ã§éåžžã«ç°¡åã§ãã â ã³ã³ãããŒã©ãããŒããã£ã¹ã¯ ãã©ã€ãã§èšå®ãããžã£ã³ã ãã¹ã€ããã¯åºæ¬çã«ãããŸããã â ã±ãŒãã«ã®äž¡ç«¯ã¯åã圢ç¶ã§ãã©ã¡ãã®ç«¯ãã³ã³ãããŒã©ã«æ¥ ç¶ããã©ã¡ãããã©ã€ãã«æ¥ç¶ãããå¿é ããå¿ èŠããããŸã ãã â ã€ã³ã¿ãŒãã§ãŒã¹ã±ãŒãã« ã³ãã¯ã¿ãã³ã³ãããŒã© ã³ãã¯ã¿ã ããŒããã©ã€ã ã³ãã¯ã¿ã¯ãäžäžã®åœ¢ç¶ãéãã®ã§ãäžæ¹å ã«ããåããŸããã 2-1 ã³ã³ãããŒã©ã®åãä»ã ã³ã³ãããŒã©ã®åãä»ã ã³ã³ãããŒã©ãã³ã³ãã¥ãŒã¿æ¬äœã«åãä»ããã«ã¯ãæ¬¡ã®æé ã« åŸããŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ãã·ã£ããããŠã³ãã黿ºã³ãŒããæã ãŸãã 2 ã³ã³ãã¥ãŒã¿ ã«ããŒãã¯ãããæªäœ¿çšã® PCI ã¹ããããæ¢ã ãŸãã 3 ã䜿ãã®ã³ã³ãã¥ãŒã¿ããããŒãããã¡ã€ã« ãã©ã±ãããã 䜿çšã§ããªãå Žåããããã«å梱ã®ããŒãããã¡ã€ã« ãã© ã±ãããåãä»ããŠãã ããã 4 æªäœ¿çšã® PCI ã¹ããããæ¢ãã以äžã«ç€ºãããã«ã¹ãããã« ããŒãåãå€ããŸãã 5 PCI ã¹ãããã«ã³ã³ãããŒã©ãåãä»ããã³ã³ãããŒã©ã®ãã© ã±ãããã³ã³ãã¥ãŒã¿æ¬äœã«åºå®ããŸãã 6 ããããŸã ã·ãªã¢ã« ATA ããŒããã©ã€ããåãä»ããŠã㪠ãã£ãå Žåã¯ãä»åãä»ãäžããã 2-2 ã³ã³ãããŒã©ã®åãä»ã 7 ãããã«å梱ã®ã±ãŒãã«ã䜿ã£ãŠãã䜿ãã®ã³ã³ãããŒã©ãšã· ãªã¢ã« ATA ããŒããã©ã€ããæ¥ç¶ããŠãã ããã ã±ãŒãã«ã®äž¡ç«¯ã®ã³ãã¯ã¿ã®åœ¢ç¶ã¯åãã§ãã©ã¡ãã®ç«¯ããã³ ã³ãããŒã©ãããŒããã£ã¹ã¯ ãã©ã€ãã«æ¥ç¶ã§ããŸããã³ã ã¯ã¿ã¯ãäžäžã®åœ¢ãéãã®ã§äžæ¹åã«ããåããŸãããã³ã³ã ããŒã©ããã©ã€ãã«ç¡çã«ã±ãŒãã«ãå ¥ããããšããªãã§äžã ããã³ãã¯ã¿ããç°¡åã«å ¥ã£ãŠãããªããã°ãå察åŽã詊ã㊠ãã ããã 8 ã³ã³ãã¥ãŒã¿ã®ã«ããŒãåãä»ããŠã黿ºã³ãŒããæ¥ç¶ã㟠ãã ã³ã³ãããŒã©ãšããã€ã¹ã®ãã§ã㯠ããã§ãAdaptec 1210SA ã³ã³ãããŒã©ãã€ã³ã¹ããŒã«ããã·ãªã¢ ã« ATA ããŒããã£ã¹ã¯ãã©ã€ãæ¥ç¶ã§ããŸããã®ã§ãARC (Adaptec RAID Configuration) ãŠãŒãã£ãªã㣠ã䜿ã£ãŠãã³ã³ã ããŒã©ãšããã€ã¹ã以äžã®ããã«ãã§ãã¯ããããšãã§ããŸãã 1 ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããŸãã 2 ããã³ããã衚瀺ãããããCtrl+A ãæŒãããšã§ãARC ãŠãŒ ãã£ãªãã£ãå®è¡ããŸãã 3 ãããã䜿ãã®ãã©ã€ãããä»ã®ã·ã¹ãã ã§ ïŒããšããã¢ã¬ ã€ã®äžéšã§ãªããšãïŒäœ¿ãããŠããããDisk Utilities ãéžæã ãŠããã©ã€ãããã©ãŒãããããŠäžããããã以å€ã¯ãæé 4 ãžé²ã¿ãŸãã ã¡ã¢ : 衚瀺ãããŠããªããã©ã€ããããå Žåã¯ãã³ã³ ãã¥ãŒã¿ã®é»æºãåããæ¥ç¶ã確èªããŠãã ããã 4 SATASelect ãéžãã§ãã³ã³ãããŒã©ãšãã©ã€ãã®ããŒããŠã§ ã¢æ§æã調ã¹ãŸãã ãã¹ãŠã®ãã©ã€ããšã³ã³ãããŒã©ã衚瀺ãããŠããããšãç¢ºèª ããŸãã衚瀺ãããŠããªããã©ã€ããããå Žåã¯ãã³ã³ãã¥ãŒ ã¿ã®é»æºãåããæ¥ç¶ã確èªããŠãã ããã 2-3 ã³ã³ãããŒã©ã®åãä»ã èµ·åã³ã³ãããŒã©ã®æ±ºå® ã䜿ãã® Adaptec 1210SA ã¯ãèµ·åå¯èœãªã³ã³ãããŒã©ã§ããã 䜿ãã®ã³ã³ãã¥ã¿ã«ããªãã¬ãŒãã£ã³ã°ã·ã¹ãã ãã€ã³ã¹ããŒã« ãããèµ·åå¯èœãªããŒããã©ã€ããããå Žåãã䜿ãã®ã³ã³ ãã¥ãŒã¿ããæ°ããã³ã³ãããŒã©ãã 2 çªç®ã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã§ããŒãããããèšå®ããããšãå¯èœã§ãã 2 çªç®ã«ããŒãå¯èœãªã³ã³ãããŒã©ã远å ããã«ã¯ãSetUp ã«å ¥ ããAdaptec 1210SA ããªã¹ãã®æåã«ãããããããŒããã£ã¹ã¯ ã®ããŒãã·ãŒã¯ãšã³ã¹ã倿Žããå¿ èŠããããŸãããã®æäœãã§ ããªãå Žåã¯ãã䜿ãã®ã·ã¹ãã BIOS ã§ã¯ Adaptec 1210SA ã³ã³ ãããŒã©ãèµ·åããã€ã¹ãšããŠåäœãããããšãã§ããªãå¯èœæ§ ããããŸãã 2-4 3 ãã©ã€ãã®ã€ã³ã¹ããŒã« ãã®ç« ã§ã¯ããã©ã€ããã€ã³ã¹ããŒã«ããã³ã³ãã¥ãŒã¿ã«æ¥ç¶ã ããã©ã€ãã«æ°ããã¢ã¬ã€ãèšå®ããæ¹æ³ã«ã€ããŠèª¬æããŸãã å§ããåã«ãWindows ã·ã¹ãã ãŸã㯠Linux ã·ã¹ãã ãžã³ã³ã ããŒã© ãã©ã€ããã€ã³ã¹ããŒã«ãã以äžã®ã±ãŒã¹ããéžã¶å¿ èŠã ãããŸãã â â 3-1 ããŒãžã®ãæ°ãã Windows ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ ããŒã«ã 3-4 ããŒãžã®ãæ¢åã® Windows ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ ããŒã«ã â 3-7 ããŒãžã®ãRed Hat Linux 7.3 ãŸã㯠8.0 ã®ã€ã³ã¹ããŒã«ã â 3-9 ããŒãžã®ãSuSE Linux 8.0 ãŸã㯠8.1 ã®ã€ã³ã¹ããŒã«ã ã¡ã¢ : ææ°ã®ãã©ã€ããããŠã³ããŒãããæ¹æ³ã«ã€ããŠã¯ã http://www.adaptec.co.jp ãŸã㯠http://www.adaptec.com ãå ç §ããŠãã ããã æ°ãã Windows ã·ã¹ãã ãžã®ãã©ã€ãã® ã€ã³ã¹ããŒã« ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ãã€ã³ã¹ããŒã«ãããŠããªãæ°ããã· ã¹ãã ã«ãã³ã³ãããŒã©ãã€ã³ã¹ããŒã«ããŸãããã©ã€ããã€ã³ ã¹ããŒã«ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 第 2 ç« ã®ã ã³ã³ãããŒã©ã®åãä»ããã«èšèŒãããŠããæé ã« åŸããã³ã³ãããŒã©ãšããŒããã£ã¹ã¯ ãã©ã€ããåãä»ã㊠èšå®ããŸãã 3-1 ãã©ã€ãã®ã€ã³ã¹ããŒã« 2 ãã©ã€ã ãã£ã¹ã¯ãäœæããŸãã a ã·ã¹ãã ã»ããã¢ããã«å ¥ããã䜿ãã®ã·ã¹ãã ããCDROM ãã©ã€ãããããŒãããããèšå®ãããŠããã確èªã ãŸãã詳现ã¯ãã·ã¹ãã ã®åæ±èª¬ææžãåç §ããŠãã ããã b Adaptec ã€ã³ã¹ããŒã« CD ãæ¿å ¥ããCD ããã·ã¹ãã ãå èµ·åããŸããèµ·åããŠã¡ã€ã³ ã¡ãã¥ãŒã衚瀺ããããŸã§ã ç»é¢ã®æç€ºã«åŸã£ãŠãæäœãé²ããŸãã c ã¡ã€ã³ã¡ãã¥ãŒãã OS ãã€ã³ã¹ããŒã« ã¢ããããŒããã ããã®ãã©ã€ããã£ã¹ã¯ã®äœæ ãã¯ãªãã¯ããŸãã d é©åãªãã©ã€ã ãã£ã¹ã¯ã®ãªãã·ã§ã³ãã¯ãªãã¯ããOK ãã¯ãªãã¯ããŸãã e ãããã㌠ãã£ã¹ã¯ãæ¿å ¥ããOK ãã¯ãªãã¯ããŸãã f ã·ã¹ãã ãããã£ã¹ã¯ããã©ãŒãããããé©åãªæ å ±ãæž ã蟌ã¿ãŸãã g ã¡ãã»ãŒãžã衚瀺ããããããã©ã€ã ãã£ã¹ã¯ãåãé€ ããã©ãã«ãã€ããŸããOK ãã¯ãªãã¯ããŸãã 3 ã³ã³ãã¥ãŒã¿ãåèµ·åããŸãã 4 ã¢ã¬ã€ãäœæããå Žåã¯ãæé 5 ãžé²ã¿ãŸããã·ã³ãã«ã ãªã¥ãŒã ã®å Žåã¯ãæé 15 ãžé²ã¿ãŸãã 5 ç»é¢ã®æç€ºã«åŸã£ãŠãCtrl+A ãæŒããŠãAdaptec RAID Configuration (ARC) ãŠãŒãã£ãªãã£ã«å ¥ããŸããARC ã䜿㣠ãŠãã¢ã¬ã€ãæ§ç¯ããè«çãã©ã€ãã« Windows ãã€ã³ã¹ã㌠ã«ããŸãã(ARC ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ããŠãã ã ãã) 6 ARC ã¡ãã¥ãŒãã Array Configuration Utility(ACU) ãéžæ ããŸãã 7 ACU ã¡ãã¥ãŒãã Create Array ãéžæããŸãã 3-2 ãã©ã€ãã®ã€ã³ã¹ããŒã« 8 æ°ããã¢ã¬ã€ã«äœ¿çšãããã©ã€ããéžæããInsert ãæŒã㟠ãã ã¡ã¢ : ã䜿ãã®ãã©ã€ããã°ã¬ã€ã«èŠããã䜿çšã§ããŸã ããããããåæåãå¿ èŠã§ãã詳现ã«ã€ããŠã¯ãA-6 ããŒãžã®ããã£ã¹ã¯ ãã©ã€ãã®åæåããåç §ããŠãã ããã 9 æ°ããã¢ã¬ã€ã«äœ¿çšãããã©ã€ããäž¡æ¹éžæã㊠Enter ãæŒã ãŸããArray Properties ã¡ãã¥ãŒã衚瀺ãããŸãã 10 Array Properties ã¡ãã¥ãŒã§ãã¢ã¬ã€ã®ã¿ã€ããéžæã㊠Enter ãæŒããŸããå©çšå¯èœãªéžæã¯ãRAID 0 ãš RAID 1 ã§ãã ãããã®ã¢ã¬ã€ã®ããããã2 ã€ã®ãã©ã€ããå¿ èŠã§ãã( ãã ãã®ã¢ã¬ã€ ã¿ã€ãã«ã€ããŠã®èª¬æã¯ãä»é² B ãåç §ããŠãã ããã) ã¡ã¢ : ã¢ã¬ã€ãäœæãããããããã£ãèšå®ããããã㢠ã¬ã€ã®ããããã£ã¯ ACU ã§å€æŽããããšã¯ã§ããŸããã ãã®ä»£ãããAdaptec Storage Manager - Browser Edition ã䜿ã£ãŠãã ããã 11 ãªãã·ã§ã³ â ã¢ã¬ã€ã®ã©ãã«ãå ¥åã㊠Enter ãæŒããŸãã 12 RAID 0 ã®ã¿ â åžæããã¹ãã©ã€ã ãµã€ãºãéžæããŸããå¯èœ ãªã¹ãã©ã€ã ãµã€ãºã¯ 16ã32ãããã³ 64KB ( åæå€ ) ã§ãã ã¡ã¢ : ã¢ããããã¯ã¯ãåæå€ã®èšå®ã¯å€æŽããªã ããš ããå§ãããŸãã 13 RAID 0 ãš RAID 1 ã§ãç°ãªãäœææ¹æ³ãéžæããŸãã( äœææ¹ æ³ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ããŠãã ããã) RAID 0âNo Init ( åæèšå® ) ãŸã㯠Migrate ãéžæããŸãã RAID 1âBuild ( åæèšå® )ãClearããŸã㯠Quick Init ãéžæ ããŸãã 14 ã¢ã¬ã€ã®æ§ç¯ãçµãã£ãããWindows ã»ããã¢ãã CD ãå ¥ ããŠãã ããããã®åŸãã·ã¹ãã ãåèµ·åããŸãã 3-3 ãã©ã€ãã®ã€ã³ã¹ããŒã« 15 ä»ç€Ÿè£œãã©ã€ãã®ã€ã³ã¹ããŒã«ãæ±ããããããF6 ããŒãæŒ ããŸãã ã¡ã¢ : F6 ããŒã®æ©èœãã¢ã¯ãã£ããªéã¯ãç»é¢äžéšã«ã ãã³ããã衚瀺ãããŸããF6 ãããã«æŒããŠãã ããã â5 ç§ä»¥å ã«æŒãå¿ èŠããããŸããããããã®æ©äŒãéã ãå Žåã¯ãWindows ã®ã€ã³ã¹ããŒã« ããã°ã©ã ãåèµ· åããŠããã®æé æ£ããå®äºããå¿ èŠããããŸããããã ãªãå ŽåãWindows ã¯ãã³ã³ãããŒã©ãæ£ããèªèã§ã ãŸããã 16 äœæãããã©ã€ã ãã£ã¹ã±ãããæ¿å ¥ãããã©ã€ãã®ã€ã³ã¹ ããŒã«ãæ±ããã¡ãã»ãŒãžã衚瀺ããããŸã§åŸ ã¡ãŸãã 17 ãã©ã€ãããããã㌠ãã£ã¹ã¯ã«ããããšãæå®ããããã«ã S ãæŒããŠãEnter ãæŒããŸãã Windows ããã£ã¹ã¯å ã®é©åãªãã©ã€ããæ¢ããŸãã 18 Adaptec Serial ATA RAID ãã©ã€ããæ€åºãããããEnter ã æŒããŸããç»é¢äžã®æç€ºã«åŸããŸãã æ¢åã® Windows ã·ã¹ãã ãžã®ãã©ã€ãã® ã€ã³ã¹ããŒã« Adaptec ã³ã³ãããŒã©ã Windows ããã§ã«ã€ã³ã¹ããŒã«ãã㊠ããã·ã¹ãã ã«è¿œå ããŸãããã©ã€ããã€ã³ã¹ããŒã«ããã«ã¯ã 以äžã®æé ã«åŸããŸãã 1 第 2 ç« ã®ã ã³ã³ãããŒã©ã®åãä»ããã«èšèŒãããŠããæé ã« åŸããã³ã³ãããŒã©ãšããŒããã£ã¹ã¯ ãã©ã€ããåãä»ã㊠èšå®ããŸãã 2 ãã©ã€ã ãã£ã¹ã¯ãäœæããŸãã a Adaptec ã€ã³ã¹ããŒã« CD ãæ¿å ¥ããèªååçãåŸ ã¡ãŸãã CD ãèªåçã«éå§ããªããã°ãCD ã®ã«ãŒããåç §ãã autorun ã®å®è¡ãã¡ã€ã«ãã¯ãªãã¯ããŸãã b ã¡ãã¥ãŒã衚瀺ããããããã©ã€ããã£ã¹ã¯ã®äœæ ã㯠ãªãã¯ããŸãã c åžæã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã衚ãçªå·ãå ¥åãã Enter ãæŒããŸãã 3-4 ãã©ã€ãã®ã€ã³ã¹ããŒã« d ã¡ãã»ãŒãžã«åŸã£ãŠããããã㌠ãã£ã¹ã¯ãæ¿å ¥ããŸãã ãã©ã€ã ãã£ã¹ã¯ã®ãã©ãŒããããè¡ãããé©åãªæ å ±ã ã³ããŒãããŸãã e ãã£ã¹ã¯ãåãé€ããã©ãã«ã貌ããŸãã 3 Windows ãèµ·åããŸããWindows ã®æ°ããããŒããŠã§ã¢ã®æ€ åºãŠã£ã¶ãŒãã衚瀺ãããã³ã³ãããŒã© ãã©ã€ããæ€çŽ¢ãã ãŸãã 4 äœæãããã©ã€ãã®ãã£ã¹ã¯ãæ¿å ¥ããŸããã³ããŒå ãšããŠã ããããŒãã£ã¹ã¯ ãã©ã€ããéžæããæ¬¡ãž ãã¯ãªãã¯ããŸãã 5 å¿ èŠãªãã°ãã䜿ãã®ãªãã¬ãŒãã£ã³ã°ã·ã¹ãã ã«ãã£ããã© ã€ããéžã³ãŸãã 6 ã³ã³ãããŒã©ã®ã€ã³ã¹ããŒã«ã®å®æã«å¿ èŠãªã®ã§ã次㞠ã㯠ãªãã¯ããŸãã 7 ãã£ã¹ã¯ãåãåºããŸãã 8 Windows 2000 ã®ã¿ â ã³ã³ãã¥ãŒã¿ãåèµ·åããŸãã 9 ã¢ã¬ã€ãäœæããå Žåã¯ãæé 10 ãžé²ã¿ãŸããã·ã³ãã«ã ãªã¥ãŒã ãã€ã³ã¹ããŒã«ããå Žåãããã§ã€ã³ã¹ããŒã«äœæ¥ã¯ çµäºã§ãã 10 ç»é¢ã®æç€ºã«åŸã£ãŠãCtrl+A ãæŒããŠãAdaptec RAID Configuration (ARC) ãŠãŒãã£ãªãã£ã«å ¥ããŸããARC ã䜿㣠ãŠãã䜿ãã®æ°ããã·ãªã¢ã« ATA ããŒã ãã©ã€ãã䜿ã£ãŠã¢ ã¬ã€ãäœæããŸãã(ARC ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ã ãŠãã ããã) 11 ARC ã¡ãã¥ãŒãã Array Configuration Utility(ACU) ãéžæ ããŸãã 12 ACU ã¡ãã¥ãŒãã Create Array ãéžæããŸãã 13 æ°ããã¢ã¬ã€ã«äœ¿çšãããã£ã¹ã¯ãéžæããInsert ãæŒã㟠ãã ã¡ã¢ : ã䜿ãã®ãã©ã€ããã°ã¬ã€ã«èŠããã䜿çšã§ããŸã ããããããåæåãå¿ èŠã§ãã詳现ã«ã€ããŠã¯ãA-6 ããŒãžã®ããã£ã¹ã¯ ãã©ã€ãã®åæåããåç §ããŠãã ããã 3-5 ãã©ã€ãã®ã€ã³ã¹ããŒã« 14 æ°ããã¢ã¬ã€ã«äœ¿çšãããã£ã¹ã¯ãäž¡æ¹éžæã㊠Enter ãæŒã ãŸããArray Properties ã¡ãã¥ãŒã衚瀺ãããŸãã 15 Array Properties ã¡ãã¥ãŒã§ãã¢ã¬ã€ã®ã¿ã€ããéžæã㊠Enter ãæŒããŸããå©çšå¯èœãªéžæã¯ãRAID 0 ãš RAID 1 ã§ãã ãããã®ã¢ã¬ã€ã®ããããã2 ã€ã®ãã©ã€ããå¿ èŠã§ãã( ãã ãã®ã¢ã¬ã€ ã¿ã€ãã«ã€ããŠã®èª¬æã¯ãä»é² B ãåç §ããŠãã ããã) ã¡ã¢ : ã¢ã¬ã€ãäœæãããããããã£ãèšå®ããããã㢠ã¬ã€ã®ããããã£ã¯ ACU ã§å€æŽããããšã¯ã§ããŸããã ãã®ä»£ãããAdaptec Storage Manager - Browser Edition ã䜿ã£ãŠãã ããã 16 ãªãã·ã§ã³ â ã¢ã¬ã€ã®ã©ãã«ãå ¥åã㊠Enter ãæŒããŸãã 17 RAID 0 ã®ã¿ â åžæããã¹ãã©ã€ã ãµã€ãºãéžæããŸããå¯èœ ãªã¹ãã©ã€ã ãµã€ãºã¯ 16ã32ãããã³ 64KB ( åæå€ ) ã§ãã ã¡ã¢ : ã¢ããããã¯ã¯ãåæå€ã®èšå®ã¯å€æŽããªã ããš ããå§ãããŸãã 18 RAID 0 ãš RAID 1 ã§ãç°ãªãäœææ¹æ³ãéžæããŸãã( äœææ¹ æ³ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ããŠãã ããã) RAID 0âNo Init ( åæèšå® ) ãŸã㯠Migrate ãéžæããŸãã RAID 1âBuild ( åæèšå® )ãClearããŸã㯠Quick Init ãéžæ ããŸãã ã¢ã¬ã€ãæ§ç¯ãå§ããããARC ãŠãŒãã£ãªãã£ãæããŠããªã ã¬ãŒãã£ã³ã°ã·ã¹ãã ãèµ·åããæ§ç¯ã®éã«ã³ã³ãã¥ãŒã¿ã䜿ã ããšãã§ããŸãã ! ãæ³šæ : æ§ç¯äžã¯ãã³ã³ãã¥ãŒã¿ã®é»æºãèœãšããªãã§äžã ãããã®å Žåããã©ã€ãã䜿çšäžèœã«ãªãå¯èœæ§ããããŸãã 3-6 ãã©ã€ãã®ã€ã³ã¹ããŒã« Red Hat Linux 7.3 ãŸã㯠8.0 ã®ã€ã³ã¹ã㌠㫠æ°ãã Linux ã·ã¹ãã ãžã® Red Hat ãã©ã€ãã®ã€ã³ã¹ããŒã« ã³ã³ãããŒã©ãæ°ãã Linux ã·ã¹ãã ã«ã€ã³ã¹ããŒã«ããŸããã ã©ã€ããã€ã³ã¹ããŒã«ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 第 2 ç« ã®ã ã³ã³ãããŒã©ã®åãä»ããã«èšèŒãããŠããæé ã« åŸããã³ã³ãããŒã©ãšããŒããã£ã¹ã¯ ãã©ã€ããåãä»ã㊠èšå®ããŸãã 2 ãã©ã€ã ãã£ã¹ã¯ãäœæããŸãã a ã·ã¹ãã ã»ããã¢ããã«å ¥ããã䜿ãã®ã·ã¹ãã ããCDROM ãã©ã€ãããããŒãããããèšå®ãããŠããã確èªã ãŸãã詳现ã¯ãã·ã¹ãã ã®åæ±èª¬ææžãåç §ããŠãã ããã b Adaptec ã€ã³ã¹ããŒã« CD ãæ¿å ¥ããCD ããã·ã¹ãã ãå èµ·åããŸããèµ·åããŠã¡ã€ã³ ã¡ãã¥ãŒã衚瀺ããããŸã§ã ç»é¢ã®æç€ºã«åŸã£ãŠãæäœãé²ããŸãã c ã¡ã€ã³ã¡ãã¥ãŒãã OS ãã€ã³ã¹ããŒã« ã¢ããããŒããã ããã®ãã©ã€ããã£ã¹ã¯ã®äœæ ãã¯ãªãã¯ããŸãã d é©åãªãã©ã€ã ãã£ã¹ã¯ã®ãªãã·ã§ã³ãã¯ãªãã¯ããOK ãã¯ãªãã¯ããŸãã e ãããã㌠ãã£ã¹ã¯ãæ¿å ¥ããOK ãã¯ãªãã¯ããŸãã f ã·ã¹ãã ãããã£ã¹ã¯ããã©ãŒãããããé©åãªæ å ±ãæž ã蟌ã¿ãŸãã g ã¡ãã»ãŒãžã衚瀺ããããããã©ã€ã ãã£ã¹ã¯ãåãé€ ããã©ãã«ãã€ããŸããOK ãã¯ãªãã¯ããŸãã 3 ã³ã³ãã¥ãŒã¿ãåèµ·åããŸãã 4 ã¢ã¬ã€ãäœæããå Žåã¯ãæé 5 ãžé²ã¿ãŸããã·ã³ãã«ã ãªã¥ãŒã ã®å Žåã¯ãæé 14 ãžé²ã¿ãŸãã 5 ç»é¢ã®æç€ºã«åŸã£ãŠãCtrl+A ãæŒããŠãAdaptec RAID Configuration (ARC) ãŠãŒãã£ãªãã£ã«å ¥ããŸããARC ã䜿㣠ãŠãã¢ã¬ã€ãæ§ç¯ããè«çãã©ã€ãã« Linux ãã€ã³ã¹ããŒã«ã ãŸãã(ARC ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ããŠãã ããã) 6 ARC ã¡ãã¥ãŒãã Array Configuration Utility(ACU) ãéžæ ããŸãã 3-7 ãã©ã€ãã®ã€ã³ã¹ããŒã« 7 ACU ã¡ãã¥ãŒãã Create Array ãéžæããŸãã 8 æ°ããã¢ã¬ã€ã«äœ¿çšãããã©ã€ããéžæããInsert ãæŒã㟠ãã ã¡ã¢ : ã䜿ãã®ãã©ã€ããã°ã¬ã€ã«èŠããã䜿çšã§ããŸã ããããããåæåãå¿ èŠã§ãã詳现ã«ã€ããŠã¯ãA-6 ããŒãžã®ããã£ã¹ã¯ ãã©ã€ãã®åæåããåç §ããŠãã ããã 9 æ°ããã¢ã¬ã€ã«äœ¿çšãããã©ã€ããäž¡æ¹éžæã㊠Enter ãæŒã ãŸããArray Properties ã¡ãã¥ãŒã衚瀺ãããŸãã 10 Array Properties ã¡ãã¥ãŒã§ãã¢ã¬ã€ã®ã¿ã€ããéžæã㊠Enter ãæŒããŸããå©çšå¯èœãªéžæã¯ãRAID 0 ãš RAID 1 ã§ãã ãããã®ã¢ã¬ã€ã®ããããã2 ã€ã®ãã©ã€ããå¿ èŠã§ãã( ãã ãã®ã¢ã¬ã€ ã¿ã€ãã«ã€ããŠã®èª¬æã¯ãä»é² B ãåç §ããŠãã ããã) ã¡ã¢ : ã¢ã¬ã€ãäœæãããããããã£ãèšå®ããããã㢠ã¬ã€ã®ããããã£ã¯ ACU ã§å€æŽããããšã¯ã§ããŸããã ãã®ä»£ãããAdaptec Storage Manager - Browser Edition ã䜿ã£ãŠãã ããã 11 ãªãã·ã§ã³ â ã¢ã¬ã€ã®ã©ãã«ãå ¥åã㊠Enter ãæŒããŸãã 12 RAID 0 ã®ã¿ â åžæããã¹ãã©ã€ã ãµã€ãºãéžæããŸããå¯èœ ãªã¹ãã©ã€ã ãµã€ãºã¯ 16ã32ãããã³ 64KB ( åæå€ ) ã§ãã ã¡ã¢ : ã¢ããããã¯ã¯ãåæå€ã®èšå®ã¯å€æŽããªã ããš ããå§ãããŸãã 13 RAID 0 ãš RAID 1 ã§ãç°ãªãäœææ¹æ³ãéžæããŸãã( äœææ¹ æ³ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ããŠãã ããã) RAID 0âNo Init ( åæèšå® ) ãŸã㯠Migrate ãéžæããŸãã RAID 1âBuild ( åæèšå® )ãClearããŸã㯠Quick Init ãéžæ ããŸãã 3-8 ãã©ã€ãã®ã€ã³ã¹ããŒã« 14 ã¢ã¬ã€ã®æ§ç¯ãçµäºããå ŽåããŸãã¯æé 4 ããç¶ç¶ããå Žå ã¯ãCD-ROM ãã©ã€ãã« Red Hat CD Disk 1 ãæ¿å ¥ããã·ã¹ ãã ãåèµ·åããŸãã 15 Red Hat ã® Welcome ç»é¢ã衚瀺ãããããããŒã ããã³ãã ã§ expert ãšå ¥åããŸãã 16 ã¡ãã»ãŒãžã衚瀺ãããããäœæãããã©ã€ã ãã£ã¹ã¯ãæ¿ å ¥ã ( æé 2 ãåç §ããŠãã ãã )ãOK ãéžæããŸãã 17 ç»é¢ã®æç€ºã«åŸã£ãŠãåžæã®ç°å¢ãã»ããã¢ããããŸãã 18 å¿ èŠã«å¿ããŠããã®ä»ã®è£œé å ã®æ©åšãåãä»ããŸããä»ã®æ© åšãåãä»ããªãå Žåã¯ãDone ãéžæããŸãã 19 Red Hat Linux ã®ããã¥ã¡ã³ãã«èšèŒãããæé ã«åŸã£ãŠã€ã³ ã¹ããŒã«ãç¶è¡ããŸãã æ¢åã® Linux ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã«ãŸã ã¯ã¢ããããŒã 以äžã®ããã«å ¥åããŠãæ¢åã® Linux ã·ã¹ãã ã®ãã©ã€ããã¢ã ãããŒããããŸãã rpm -Uvh aar1210-*.*.*-*.i386.rpm * ã«ã¯ããã©ã€ã ãã¡ã€ã«ã®ååãå ¥åããŸãã SuSE Linux 8.0 ãŸã㯠8.1 ã®ã€ã³ã¹ããŒã« æ°ãã Linux ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã« ã³ã³ãããŒã©ãæ°ãã Linux ã·ã¹ãã ã«ã€ã³ã¹ããŒã«ããŸããã ã©ã€ããã€ã³ã¹ããŒã«ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 第 3 ç« ã®ã ãã©ã€ãã®ã€ã³ã¹ããŒã«ãã«èšèŒãããŠããæé ã« åŸããã³ã³ãããŒã©ãšããŒããã£ã¹ã¯ ãã©ã€ããåãä»ã㊠èšå®ããŸãã 2 ãã©ã€ã ãã£ã¹ã¯ãäœæããŸãã a ã·ã¹ãã ã»ããã¢ããã«å ¥ããã䜿ãã®ã·ã¹ãã ããCDROM ãã©ã€ãããããŒãããããèšå®ãããŠããã確èªã ãŸãã詳现ã¯ãã·ã¹ãã ã®åæ±èª¬ææžãåç §ããŠãã ããã b Adaptec ã€ã³ã¹ããŒã« CD ãæ¿å ¥ããCD ããã·ã¹ãã ãå èµ·åããŸããèµ·åããŠã¡ã€ã³ ã¡ãã¥ãŒã衚瀺ããããŸã§ã ç»é¢ã®æç€ºã«åŸã£ãŠãæäœãé²ããŸãã 3-9 ãã©ã€ãã®ã€ã³ã¹ããŒã« c ã¡ã€ã³ã¡ãã¥ãŒãã OS ãã€ã³ã¹ããŒã« ã¢ããããŒããã ããã®ãã©ã€ããã£ã¹ã¯ã®äœæ ãã¯ãªãã¯ããŸãã d é©åãªãã©ã€ã ãã£ã¹ã¯ã®ãªãã·ã§ã³ãã¯ãªãã¯ããOK ãã¯ãªãã¯ããŸãã e ãããã㌠ãã£ã¹ã¯ãæ¿å ¥ããOK ãã¯ãªãã¯ããŸãã f ã·ã¹ãã ãããã£ã¹ã¯ããã©ãŒãããããé©åãªæ å ±ãæž ã蟌ã¿ãŸãã g ã¡ãã»ãŒãžã衚瀺ããããããã©ã€ã ãã£ã¹ã¯ãåãé€ ããã©ãã«ãã€ããŸããOK ãã¯ãªãã¯ããŸãã 3 ã³ã³ãã¥ãŒã¿ãåèµ·åããŸãã 4 ã¢ã¬ã€ãäœæããå Žåã¯ãæé 5 ãžé²ã¿ãŸããã·ã³ãã«ã ãªã¥ãŒã ã®å Žåã¯ãæé 14 ãžé²ã¿ãŸãã 5 ç»é¢ã®æç€ºã«åŸã£ãŠãCtrl+A ãæŒããŠãAdaptec RAID Configuration (ARC) ãŠãŒãã£ãªãã£ã«å ¥ããŸããARC ã䜿㣠ãŠãã¢ã¬ã€ãæ§ç¯ããè«çãã©ã€ãã« Linux ãã€ã³ã¹ããŒã«ã ãŸãã(ARC ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ããŠãã ããã) 6 ARC ã¡ãã¥ãŒãã Array Configuration Utility(ACU) ãéžæ ããŸãã 7 ACU ã¡ãã¥ãŒãã Create Array ãéžæããŸãã 8 æ°ããã¢ã¬ã€ã«äœ¿çšãããã©ã€ããéžæããInsert ãæŒã㟠ãã ã¡ã¢ : ã䜿ãã®ãã©ã€ããã°ã¬ã€ã«èŠããã䜿çšã§ããŸã ããããããåæåãå¿ èŠã§ãã詳现ã«ã€ããŠã¯ãA-6 ããŒãžã®ããã£ã¹ã¯ ãã©ã€ãã®åæåããåç §ããŠãã ããã 9 æ°ããã¢ã¬ã€ã«äœ¿çšãããã©ã€ããäž¡æ¹éžæã㊠Enter ãæŒã ãŸããArray Properties ã¡ãã¥ãŒã衚瀺ãããŸãã 3-10 ãã©ã€ãã®ã€ã³ã¹ããŒã« 10 Array Properties ã¡ãã¥ãŒã§ãã¢ã¬ã€ã®ã¿ã€ããéžæã㊠Enter ãæŒããŸããå©çšå¯èœãªéžæã¯ãRAID 0 ãš RAID 1 ã§ãã ãããã®ã¢ã¬ã€ã®ããããã2 ã€ã®ãã©ã€ããå¿ èŠã§ãã( ãã ãã®ã¢ã¬ã€ ã¿ã€ãã«ã€ããŠã®èª¬æã¯ãä»é² B ãåç §ããŠãã ããã) ã¡ã¢ : ã¢ã¬ã€ãäœæãããããããã£ãèšå®ããããã㢠ã¬ã€ã®ããããã£ã¯ ACU ã§å€æŽããããšã¯ã§ããŸããã ãã®ä»£ãããAdaptec Storage Manager - Browser Edition ã䜿ã£ãŠãã ããã 11 ãªãã·ã§ã³ â ã¢ã¬ã€ã®ã©ãã«ãå ¥åã㊠Enter ãæŒããŸãã 12 RAID 0 ã®ã¿ â åžæããã¹ãã©ã€ã ãµã€ãºãéžæããŸããå¯èœ ãªã¹ãã©ã€ã ãµã€ãºã¯ 16ã32ãããã³ 64KB ( åæå€ ) ã§ãã ã¡ã¢ : ã¢ããããã¯ã¯ãåæå€ã®èšå®ã¯å€æŽããªã ããš ããå§ãããŸãã 13 RAID 0 ãš RAID 1 ã§ãç°ãªãäœææ¹æ³ãéžæããŸãã( äœææ¹ æ³ã®è©³çްã«ã€ããŠã¯ãä»é² A ãåç §ããŠãã ããã) RAID 0âNo Init ( åæèšå® ) ãŸã㯠Migrate ãéžæããŸãã RAID 1âBuild ( åæèšå® )ãClearããŸã㯠Quick Init ãéžæ ããŸãã 14 ã¢ã¬ã€ã®æ§ç¯ãçµäºããå ŽåããŸãã¯æé 4 ããç¶ç¶ããå Žå ã¯ãCD-ROM ãã©ã€ãã« SuSE CD Disk 1 ãæ¿å ¥ããã·ã¹ãã ãåèµ·åããŸãã 15 SuSE Installation ã¡ãã¥ãŒã衚瀺ãããããAlt ãæŒããã¡ ãã¥ãŒãããªãã·ã§ã³ã 1 ã€éžæã㊠Enter ãæŒããŸãã 16 ã¡ãã»ãŒãžã衚瀺ãããããäœæãããã©ã€ã ãã£ã¹ã¯ãæ¿ å ¥ã ( æé 2 ãåç §ããŠãã ãã )ãããããã®ããŒãæŒã㊠åŠçãç¶ç¶ããŸãã 17 ç»é¢ã®æç€ºã«åŸã£ãŠãåžæã®ç°å¢ãã»ããã¢ããããŸãã 18 SuSE Linux ã®ããã¥ã¡ã³ãã«èšèŒãããæé ã«åŸã£ãŠã€ã³ã¹ ããŒã«ãç¶è¡ããŸãã 3-11 ãã©ã€ãã®ã€ã³ã¹ããŒã« æ¢åã® Linux ã·ã¹ãã ãžã®ãã©ã€ãã®ã€ã³ã¹ããŒã«ãŸã ã¯ã¢ããããŒã 以äžã®ããã«å ¥åããŠãæ¢åã® SuSE Linux ã·ã¹ãã ã®ãã©ã€ãã ã¢ããããŒããããŸãã rpm -Uvh aar1210-*.*.*-*.i386.rpm * ã«ã¯ããã©ã€ã ãã¡ã€ã«ã®ååãå ¥åããŸãã 3-12 4 Adaptec Storage Managerâ Browser Edition ã®ã€ã³ã¹ ããŒã« ãã®ç« ã®æŠèŠ æŠèŠ 4-1 ãµããŒããããã©ãŠã¶ 4-2 ã«ã¹ã¿ã åã³ ã³ã³ãã¯ã ã€ã³ã¹ããŒã« 4-2 Adaptec Storage Manager Browser Edition ã® Windows ãžã®ã€ã³ 4-3 ã¹ããŒã« Adaptec Storage Manager Browser Edition ã® Linux ãžã®ã€ã³ã¹ ããŒã« 4-7 æŠèŠ ãã®ç« ã§ã¯ããªã¢ãŒãåã³ããŒã«ã«ã®ã¢ã¬ã€ã®ç®¡çãã§ãããã ã«ãªã Adaptec Storage Manager â Browser Edition ãã€ã³ã¹ã㌠ã«ããã€ã³ã¹ããŒã«æé ã«ã€ããŠèª¬æããŸãããã®ã¢ãã¬ãªãŒ ã·ã§ã³ã䜿ãã«ã¯ã第 5 ç« ãåç §ããŠãã ããã 4-1 Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã« ãµããŒããããã©ãŠã¶ Adaptec Storage Manager â Browser Edition ãå®è¡ããã«ã¯ãã 䜿ãã®ã³ã³ãã¥ãŒã¿ã«ã¯ Javascript ãš cookie ã®ã¿ã«å¯Ÿå¿ãã Web ãã©ãŠã¶ãå¿ èŠã§ãã以äžã®ããŒãžã§ã³ããµããŒããããŸãã â â Windows ã·ã¹ãã â Internet Explorer (IE) 5.0 以é â Netscape 7 以é Linux ã·ã¹ãã â Adaptec ãæäŸãã€ã³ã¹ããŒã«æžã¿ã® Mozilla â Netscape 7 以é Adaprec Storage Manager ã䜿ãéã¯ãã䜿ãã®ã·ã¹ãã ã«ç®¡ç è ã®æš©éã§ãã°ã€ã³ããå¿ èŠããããŸãã ã«ã¹ã¿ã åã³ ã³ã³ãã¯ã ã€ã³ã¹ããŒã« ãããã«ã¹ã¿ã ããã³ã³ãã¯ãã®ã€ã³ã¹ããŒã«ãèããŠããå Žå ã¯ãã€ã³ã¹ããŒã«ã®åã«ãã®é ãèªãã§ãã ããããã以å€ã¯ã 次ãžé²ãã§ãã ããã以äžã®èšå®ãªãã·ã§ã³ã䜿çšã§ããŸãã â æšæº ( åæå€ )â ããŒã«ã«ãšãªã¢ãŒãã®ç®¡çã«å¯Ÿå¿ããŠããŸã ããAdaptec SNMP ã¯å«ãŸããŠããŸããã â ã«ã¹ã¿ã â äžçŽã®ãŠãŒã¶ã§ãç¹å®ã®ã³ã³ããŒãã³ããéžãã§ã€ ã³ã¹ããŒã«ãããå Žåã以äžã®ã³ã³ããŒãã³ããå«ãŸããŠã㟠ãã â 管çã·ã¹ãã ã³ã³ããŒãã³ã â ãã®ã»ã¯ã·ã§ã³ã®ã¿ãéžã ã å Žåãã€ã³ã¹ããŒã«ã®å 容ã¯ãã³ã³ãã¯ã ã€ã³ã¹ããŒã« ãšåãã§ãã â Adaptec Web Serverâ 管çã·ã¹ãã ããWeb ãã©ãŠã¶ãšé ä¿¡ããããšãå¯èœã«ããã³ã³ããŒãã³ããã€ã³ã¹ããŒã«ã ãŸãã â Adaptec Storage Manager Notifierâ é»åã¡ãŒã«ãšãããŒã ãã£ã¹ãæ©èœãå«ãã¡ãã»ãŒãžã³ã°ãã€ã³ã¹ããŒã«ããŸãã 4-2 Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã« â â Adaptec SNMPâSNMP ããŒã¹ã®ã¢ããªã±ãŒã·ã§ã³ã䜿㣠ãã³ã³ããŒãã³ããã€ã³ã¹ããŒã«ããŸããMicrosoft SNMP ãšãŒãžã§ã³ããã€ã³ã¹ããŒã«ããå¿ èŠããããŸããæšæº ã€ ã³ã¹ããŒã«ã«ã¯å«ãŸããŸããã ã³ã³ãã¯ãâãªã¢ãŒãã§ã®ç®¡çã·ã¹ãã ã«å¿ èŠãªã³ã³ããŒãã³ ãã®ã¿ãã€ã³ã¹ããŒã«ããŸãã管çã·ã¹ãã ã³ã³ããŒãã³ãã åç §ããŠãã ããã ã¡ã¢ : Adaptec Storage Manager ãã€ã³ã¹ããŒã«ããæãä» ã® Adaptec ã³ã³ãããŒã©ã®äºææ§ã«å¿ èŠãªãCLI (Command Line Interpreter) ãã€ã³ã¹ããŒã«ããããšã«ããªããŸãã Adaptec Storage Manager Browser Edition ã® Windows ãžã®ã€ã³ã¹ããŒã« ã¡ã¢ : FAT 32 ãã¡ã€ã«ã·ã¹ãã ã«ã€ã³ã¹ããŒã«ããå Žåã¯ã ã€ã³ã¹ããŒã«å ã®ãã©ã«ãã¯èªåçã«é衚瀺ã«ãªããŸãã Adaptec Storage Manager â Browser Edition ã®ã€ã³ã¹ããŒã« 1 ãµããŒãããããã©ãŠã¶ãã€ã³ã¹ããŒã«ãããŠããã確èªã㊠ãã ããã詳现ã«ã€ããŠã¯ã4-2 ããŒãžã®ããµããŒããããã© ãŠã¶ãããåç §ãã ããã 2 Adaptec ã€ã³ã¹ããŒã« CD ãæ¿å ¥ããAutorun å®è¡ãã¡ã€ã«ãã ã€ã³ã¹ããŒã«ãå§ããã®ãåŸ ã¡ãŸããèªåçã«èµ·åããªãå Žå ã¯ãCD ãåç §ããAutorun ãããã«ã¯ãªãã¯ããŸãã 3 Adaptec Storage Manager â Browser Edition ã®ã€ã³ã¹ããŒã« ãã¯ãªãã¯ããŸãã 4 Install Shield ãŠã£ã³ããŠã§ã次㞠ãã¯ãªãã¯ããŸãã 5 䜿çšèš±è«Ÿå¥çŽãèªã¿ãŸããåæãããªããã¯ã ãã¯ãªãã¯ã ãŸããåæããªãå Žåã¯ãããã ãã¯ãªãã¯ããŠãã€ã³ã¹ ããŒã«ãäžæ¢ããŸãã ã»ããã¢ããã¿ã€ãã®éžæ ãŠã£ã³ããŠã衚瀺ãããŸããæšæºã ã³ã³ãã¯ããã«ã¹ã¿ã ãšãã 3 ã€ã®ã€ã³ã¹ããŒã« ãªãã·ã§ã³ ã衚瀺ãããŸãã詳现ã«ã€ããŠã¯ã4-2 ããŒãžã®ãã«ã¹ã¿ã å ã³ ã³ã³ãã¯ã ã€ã³ã¹ããŒã«ãããåç §ãã ããã 4-3 Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã« 6 ã»ããã¢ãã ã¿ã€ããéžãã§ã次㞠ãã¯ãªãã¯ããŸãã 7 Destination folder ã確èªããæ¬¡ãž ãã¯ãªãã¯ããŸãã 8 ã»ããã¢ããæ å ± ã§ã次㞠ãã¯ãªãã¯ããŸãã ã¹ã¯ããŒã« ããŒãä»ãã ã»ããã¢ãã ã¹ããŒã¿ã¹ ãŠã£ã³ã㊠ã«ãé²æç¶æ³ã衚瀺ãããŸããã¹ã¯ããŒã«ããŒããã€ã³ã¹ã㌠ã«ãå®äºããããšã瀺ãåã«ãã»ãã¥ãªãã£èªèšŒãäœæããã ããšã瀺ããŠã£ã³ããŠãããããã¢ããããŸãã 9 OK ãã¯ãªãã¯ããŸãã ã«ãŒãèšŒææžã¹ã㢠ãŠã£ã³ãã衚瀺ãããŸãã 10 ã¯ããã¯ãªãã¯ããŸãã ã€ã³ã¹ããŒã«äžã«çæãããã»ãã¥ãªãã£èšŒææžã¯ãèšŒææž ã¹ãã¢ã«è¿œå ãããŸãããããã§ãããã ãã¯ãªãã¯ãããšã æåã« Adaptec Storage Manager ãåããŠäœ¿çšããæã«ãèªèšŒ ãã€ã³ã¹ããŒã«ããå¿ èŠããããŸãã 11 åèµ·åãæ±ããããããåæå€ ( ã¯ã ) ãåãå ¥ããå®äº ã㯠ãªãã¯ããŸãã 12 ã·ã¹ãã ã®åèµ·åãéå§ãããã€ã³ã¹ããŒã«ãå®äºããŸãã 13 ã·ã¹ãã ãåèµ·åããåã«ãAdaptec ã€ã³ã¹ããŒã« CD ãåã é€ããªããšãã€ã³ã¹ããŒã«äœæ¥ãå床å§ãŸããŸãã Windows ã® ã€ã³ã¿ãŒããã ãã©ãŠã¶ã®èšå® ããŒã«ã« ã¹ãã¬ãŒãžã¢ã¬ã€ã管çããã䜿ãã® PC ããããã· ãµãŒãã䜿ã£ãŠããå ŽåãAdaptec Storage Manager ã ãããã· ãµãŒãããã€ãã¹ã§ããããããã©ãŠã¶ãèšå®ããå¿ èŠããã㟠ãããŸãããªã¢ãŒãã·ã¹ãã ã管çããŠãããªãã°ãAdaptec Storage Manager ããããã®ã·ã¹ãã ãšéä¿¡ããæã«ããããã· ãµãŒãããã€ãã¹ããããèšå®ããå¿ èŠããããŸãã ãã®é ã§ã¯ã以äžã®æé ã«ã€ããŠèª¬æããŸãã â 4-5 ããŒãžã®ãInternet Explorer ã ããŒã«ã«ç®¡çã§èšå®ããã â 4-6 ããŒãžã®ãInternet Explorer ã ãªã¢ãŒã管çã§èšå®ããã â 4-6 ããŒãžã®ãNetscape Navigator ã ããŒã«ã«ç®¡çã§èšå®ããã â 4-6 ããŒãžã®ãNetscape Navigator ã ãªã¢ãŒã管çã§èšå®ããã 4-4 Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã« Internet Explorer ã ããŒã«ã«ç®¡çã§èšå®ãã é« ã¬ãã«ã®ã»ãã¥ãªãã£ã䜿çšããå Žåã¯ã以äžã®ã€ã³ãã©ãã ãã®èšå®ãæåã§æå¹ã«ããå¿ èŠããããŸãã â JavaScript â Cookie ( ä¿åãªã ) Internet Explorer 5 ããã³ 5.5 ã§ã¯ãããŒã«ã« ã€ã³ãã©ãããã«ã€ ããŠä»¥äžã®ã«ã¹ã¿ã ã¬ãã«ã®ã»ãã¥ãªãã£èšå®ãæå¹ã«ãã å¿ èŠ ããããŸãããããŒã« > ã€ã³ã¿ãŒããã ãªãã·ã§ã³ ã®é ã«éžæã ããšããããã®èšå®ã«ã¢ã¯ã»ã¹ã§ããŸãã â ã¢ã¯ãã£ã ã¹ã¯ãªãã â ã»ãã·ã§ã³ããšã® Cookie ã®äœ¿çšèš±å¯ ( ä¿åãªã ) ã¡ã¢ : Internet Explorer 6.0 ã§ã¯ããã® cookies ã«é¢ããã» ãã¥ãªãã£èšå®ã¯ãããŸãããCookie ã®èšå®ã¯ãã©ã€ã ã·ãŒã¿ãããåé€ãããŠããŸãããã®ãããã€ã³ãã© ãããã® Cookie ããããã¯ããèšå®ã¯ããã«ã¯ãããŸã ãã ã€ã³ã¿ãŒããããžã®ã¢ã¯ã»ã¹ã«ãããã· ãµãŒããŒã䜿çšããŠãã å ŽåãAdaptec Storage Manager Web ãµãŒããŒã«ã¢ã¯ã»ã¹ããã« ã¯ããããã· ãµãŒããŒããã€ãã¹ããå¿ èŠããããŸãããããã· ãµãŒãã䜿ã£ãŠãããã©ããã確èªããã«ã¯ã以äžã®æé ã«åŸã ãŸãã 1 ã€ã³ã¿ãŒããããªãã·ã§ã³ ãŠã£ã³ããŠãããæ¥ç¶ ã¿ã 2 LAN ã®èšå® ãã¯ãªã㯠â ãããã· ãµãŒããŒã䜿çšãã ãã§ã㯠ããã¯ã¹ããªãã®å Ž åã«ã¯ãOK ãã¯ãªãã¯ããŠçµäºããŸãããããã· ãµãŒã ã䜿çšããŠããªãå Žåã«ã¯ããã®èšå®ã倿Žããå¿ èŠã¯ã ããŸãã â ãããã· ãµãŒããŒã䜿çšãã ãã§ã㯠ããã¯ã¹ããªã³ã®å Ž åã«ã¯ãããŒã«ã«ã«ã¯ ãããã· ãµãŒããŒã䜿çšããªããã ã¯ã¹ããã§ãã¯ããŠããããšã確èªããŸãããã®åŸã詳现 èšå® ãã¿ã³ãæŒããŸããäŸå€ãŠã£ã³ããŠã®ãšã³ããªã«ã localhost ãšå ¥åããŸãã 4-5 Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã« ããã§ã第 5 ç« ã®ã Adaptec Storage Managerâ Browser Edition ã®äœ¿ çšããžé²ãæºåãã§ããŸããã Internet Explorer ã ãªã¢ãŒã管çã§èšå®ãã ãªã¢ãŒãã§ç®¡çãããã·ã¹ãã ã®ãIP ã¢ãã¬ã¹ãç¥ã£ãŠããå Žå ã¯ã以äžã®æé ã«åŸããŸãã 1 ããŒã« > ã€ã³ã¿ãŒããã ãªãã·ã§ã³ > æ¥ç¶ > LAN ã®èšå® ã®é ã«éžæããŸãã 2 LAN ã«ãããã· ãµãŒããŒã䜿çšãã > 詳现èšå® ãéžæã㟠ãã 3 äŸå€ ã»ã¯ã·ã§ã³ã«ç®¡çã·ã¹ãã ã® IP ã¢ãã¬ã¹ãå ¥åããŸãã Netscape Navigator ã ããŒã«ã«ç®¡çã§èšå®ãã ã¡ã¢ : ãããã¯ç¹ã«ãããŒãžã§ã³ 7 ã«é©çšãããåŸã®ã㌠ãžã§ã³ã§ã¯ç°ãªãå¯èœæ§ããããŸãã Netscape Navigator ãèšå®ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 管çè ã®æš©éã§ãã䜿ãã®ã³ã³ãã¥ãŒã¿ã«ãã°ã€ã³ããŸãã 2 Netscape ã¡ã€ã³ç»é¢ãããç·šé > èšå® ãéžæããŸãã 3 èšå®ãŠã£ã³ããŠã§ããã©ã€ãã·ãŒãšã»ãã¥ãªãã£ã®è¡ã®å³ç¢å° ãã¯ãªãã¯ããŸããCokkies ãæå¹ã«ãã éžæè¢ãéžæãã ãŠããããšã確èªããŸãã 4 詳现 è¡ãéžæããŸããJavascript ãæå¹ã«ããã§ Navigator ã« ãã§ãã¯ããŒã¯ãä»ããŠããããšã確èªããŸãã 5 Navigator ãçµäºããŠããåèµ·åããŸãã倿Žããèšå®ãæå¹ ã«ãªããŸãã 6 ããã§ã第 5 ç« ã®ã Adaptec Storage Managerâ Browser Edition ã®äœ¿çšããžé²ãæºåãã§ããŸããã Netscape Navigator ã ãªã¢ãŒã管çã§èšå®ãã ãªã¢ãŒãã§ç®¡çãããã·ã¹ãã ã®ãIP ã¢ãã¬ã¹ãç¥ã£ãŠããå Žå ã¯ã以äžã®æé ã«åŸããŸãã 1 ç·šé > èšå® > 詳现 > ãããã· > æåã§ãããã·ãèšå®ãã > ãããã·ãªã ã®é ã«éžæããŸãã 4-6 Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã« 2 管çã·ã¹ãã ã® IP ã¢ãã¬ã¹ãã¿ã€ãããŸãã Adaptec Storage Manager Browser Edition ã® Linux ãžã®ã€ã³ã¹ããŒã« ã¡ã¢ : ãã®ã€ã³ã¹ããŒã«ã®å®è¡äžã¯ãLinux ã§ã¯å€§æå / å° æåã®åºå¥ãããããšã«æ³šæããŠãã ããã Adaptec Storage Manager ããLinux ã®ã³ã³ãã¥ãŒã¿ã«ã€ã³ã¹ã㌠ã«ããåžæã®ã€ã³ã¿ãŒããããã©ãŠã¶ã«èšå®ããã«ã¯ã以äžã®æ é ã«åŸããŸãã 1 Adaptec ã€ã³ã¹ããŒã« CD ãæ¿å ¥ããŸãã 2 以äžã®ããã«ã¿ã€ãããŠããœãããŠã§ã¢ãã€ã³ã¹ããŒã«ã㟠ãã sh <mount-point>/install.sh. <mount-point> ã¯ã³ã³ãã¥ãŒã¿ã«ãã£ãŠéããŸãããæ®ã©ã®å Ž åã/mnt/cdrom, /media/cdromããŸã㯠cdrom ã§ãã Welcome ãŠã£ã³ããŠã衚瀺ãããŸãã 3 次㞠ãã¯ãªãã¯ããŸãã 䜿çšèš±è«Ÿå¥çŽ ãŠã£ã³ããŠã衚瀺ãããŸãã 4 䜿çšèš±è«Ÿå¥çŽãèªã¿ãŸããå¥çŽã«åæãããªããæ¿è«Ÿ ã㯠ãªãã¯ããŸããæ¿è«Ÿããªãå Žåã¯ããã£ã³ã»ã« ãã¯ãªãã¯ã ãŠãã€ã³ã¹ããŒã«ãçµäºããŸãã ã»ããã¢ããã¿ã€ãã®éžæ ãŠã£ã³ããŠã衚瀺ãããŸããæšæºã ã³ã³ãã¯ããã«ã¹ã¿ã ãšãã 3 ã€ã®ã€ã³ã¹ããŒã« ãªãã·ã§ã³ ã衚瀺ãããŸãã詳现ã«ã€ããŠã¯ã4-2 ããŒãžã®ãã«ã¹ã¿ã å ã³ ã³ã³ãã¯ã ã€ã³ã¹ããŒã«ãããåç §ãã ããã 5 ã»ããã¢ãã ã¿ã€ããéžãã§ã次㞠ãã¯ãªãã¯ããŸãã ã³ããŒãéå§ãã ãŠã£ã³ããŠã衚瀺ãããŸãã 6 次㞠ãã¯ãªãã¯ããŸãã èªåã»ããã¢ããå®è¡ ãŠã£ã³ããŠã®ããã¹ãéšåã«ãã·ã¹ã ã ã«ããŒãããããã¡ã€ã«ã衚瀺ãããŸãã 4-7 Adaptec Storage ManagerâBrowser Edition ã®ã€ã³ã¹ããŒã« 7 ããã³ããã衚瀺ãããããæ¬¡ãž ãã¯ãªãã¯ããŸãã ã»ããã¢ããå®äºã®ãŠã£ã³ããŠããããããŸãã 8 å®äº ãã¯ãªãã¯ããŸãã RAID 管çã¢ããªã±ãŒã·ã§ã³ãåäœããããããããã· ãµãŒã ããã€ãã¹ããå¿ èŠãããããšãéç¥ããã¡ãã»ãŒãž ãŠã£ã³ ããŠã衚瀺ãããŸãã 9 OK ãã¯ãªãã¯ããŸãã ã€ã³ã¹ããŒã«ãéå§ããã·ã§ã«ã®ã·ã§ã« ãŠã£ã³ããŠã«ã daemon ãããã€ãèµ·åäžã§ããããšã瀺ãããŸã ã€ã³ã¹ããŒã«ã¯ãã·ã¹ãã ã¿ãå ã® Adaptec Storage Manager ã®ã·ã§ãŒãã«ãããäœæããŸãããã®ã·ã§ãŒãã«ããã¯ã Mozilla ã䜿ã£ãŠ Adaptec Storage Manager ãèµ·åããŸãã ã³ã³ãããŒã©ãã©ã€ãããã®ã€ã³ã¹ããŒã«äžã«ã€ã³ã¹ããŒã«ã ããªãéããã³ã³ãã¥ãŒã¿ãåèµ·åããå¿ èŠã¯ãããŸããã 10 Adaptec ã€ã³ã¹ããŒã« CD ãåãé€ããŸãã ã䜿ãã®ã³ã³ãã¥ãŒã¿ã«ã¯ Javascript ãš cookie ããµããŒããã Web ãã©ãŠã¶ãå¿ èŠã§ããAdaprec Storage Manager ã䜿ãéã¯ã ã䜿ãã®ã·ã¹ãã ã«ç®¡çè ã®æš©éã§ãã°ã€ã³ããå¿ èŠããããŸãã 4-8 5 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ãã®ç« ã®æŠèŠ æŠèŠ 5-2 ã¢ãŒããã¯ãã£ã®æŠèŠ 5-3 ãã° ã€ã³ 5-4 ã»ãã¥ãªãã£èªèšŒã®äœæ 5-5 ãŠãŒã¶ç»é² 5-6 åºæ¬äºé 5-7 ã¢ã¬ã€ã®äœæ 5-12 ã¢ã¬ã€ã®åé€ 5-15 ã¢ã¬ã€ã®å€æŽ 5-16 ãŠãŒã¶ ã€ã³ã¿ãŒãã§ã€ã¹ ãªãã·ã§ã³ 5-17 ã€ãã³ãã®è¡šç€º 5-18 ãã«ãã®äœ¿çš 5-20 ããããã£ã®è¡šç€ºãšå€æŽ 5-20 ã¿ã¹ã¯ã®è¡šç€ºãšäœæ 5-26 5-1 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš æŠèŠ ãã®ç« ã§ã¯ãã¢ã¬ã€ã管çããããã® Adapetc Storage Managerâ Browser Edition ã®äœ¿ãæ¹ã説æããŸãããã°ã€ã³ããã°ãã¢ã¬ã€ ã®æ§ç¯ãèšå®ã管çã«ã€ããŠã®è©³çްã説æããã䟿å©ãªãªã³ã©ã€ ã³ãã«ãããããŸãã ã¡ã¢ : ã䜿ãã®ã³ã³ãããŒã©ããããã«èšèŒãããŠãããã¹ ãŠã®æ©èœããµããŒãããŠããªãå ŽåããããŸããã»ãšãã©ã® å Žåãã³ã³ãããŒã©ã§ãµããŒããããŠããªãæ©èœããã£ãå Ž åããã®æ©èœã¯ ã€ã³ã¿ãŒãã§ãŒã¹ ã«ã¯è¡šç€ºãããŸããã Adaptec Storage Manager ã§ã以äžã®ããšãã§ããŸãã â Windows ã Linux åã³ãµããŒãããããã©ãŠã¶ãã€ã³ã¹ã㌠ã«ãããŠããã°ããµããŒãããã Adaptec RAID ã³ã³ãããŒã© ãå«ãã ã·ã¹ãã ãããŒã«ã«ã§ç®¡çããŸãã â 管çã·ã¹ãã ã³ã³ããŒãã³ã ( 詳现ã¯ã4-2 ããŒãžã®ãã«ã¹ã¿ã åã³ ã³ã³ãã¯ã ã€ã³ã¹ããŒã«ãåç § ) ããã€ããµããŒãããã Adaptec RAID ã³ã³ãããŒã©ãå«ãã ã·ã¹ãã ããªã¢ãŒãã§ç®¡ çããŸãããã¹ãã·ã¹ãã ã« RAID ã³ã³ãããŒã©ããªããšãã ãªã¢ãŒãã·ã¹ãã ã管çããããšãã§ããŸãããŸããARCPD ãšãŒãžã§ã³ããã€ã³ã¹ãŒã«ãããŠããå ŽåãUnix ã Netware ã§åäœããŠãããªã¢ãŒãã·ã¹ãã ã管çããããšãã§ããŸãã ãã®ãã㪠Windows ããã³ Linux ã·ã¹ãã ããªã¢ãŒããã管ç ããããšãã§ããŸãããã®å Žåã以äžã® 2 éãã®æ¹æ³ããããŸãã â ãªã¢ãŒã ã·ã¹ãã ã« Adaptec Storage Manager ãã€ã³ã¹ããŒã« ããŸãã â ãªã¢ãŒã ã·ã¹ãã ã®ãã©ãŠã¶ããã管çãããã·ã¹ãã ã«ã¢ ã¯ã»ã¹ããŸãã ã¡ã¢ : Lnux ã·ã¹ãã ãããªã¢ãŒãã§ç®¡çããã«ã¯ãAdaptec Storage Manager ãã·ã¹ãã ã«ã€ã³ã¹ããŒã«ããAdaptec ã® æäŸããããŒãžã§ã³ã® Mozilla ããã©ãŠã¶ãšããŠå©çšã㟠ãã 5-2 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã¢ãŒããã¯ãã£ã®æŠèŠ Adaptec Storage Managerâ Browser Edition ã®äž»èŠãªã³ã³ããŒãã³ ãã¯ã次㮠3 ã€ã§ãã â ãµããŒããããŠãã Web ãã©ãŠã¶ããããããã·ã¹ãã ã«ã€ ã³ã¹ããŒã«ããŠããå¿ èŠããããŸãã â Adaptec Web ãµãŒãã¹ãWeb ãã©ãŠã¶ã«è¡šç€ºãããå å®¹ãæ äŸããŸãã â Adaptec ãæäŸããã¹ãã¬ãŒãž ãšãŒãžã§ã³ãã ããŒã«ã«ã§ã·ã¹ãã ã管çããå Žåã¯ã3 ã€ã®ã³ã³ããŒãã³ãã ãã¹ãŠåäžã·ã¹ãã ã«ã€ã³ã¹ããŒã«ããå¿ èŠããããŸãã 以äžã§èª¬æãããªã¢ãŒãç®¡çæ§æããµããŒãããã«ã¯ãTCP/IP ã§æ¥ç¶ãããŠããã·ã¹ãã ã«ãã¹ãŠã®ã³ã³ããŒãã³ããã€ã³ã¹ ããŒã«ããŸããã³ã³ããŒãã³ãéã®é信㯠TCP/IP ãä»ããŠè¡ã ãŸãã ãã¹ãŠã®éä¿¡ã§ãS-HTTP (Secure-HTTP) ãŸã㯠SSL ãããã³ã« ã䜿ã£ãŠããŒã¿ãæå·åãããã»ãã¥ãªãã£ã確ä¿ããŸãã Ethernet ãããã¯ãŒã¯ãä»ããæ¥ç¶ãäŒæ¥å WANãããã³ VPN ããµããŒããããŠããŸãã å¯èœãªãªã¢ãŒãç®¡çæ§æã¯ä»¥äžã®ãšããã§ãã â ãªã¢ãŒãã·ã¹ãã ã¯ããã©ãŠã¶ãã€ã³ã¹ããŒã«ããã â RAID ã³ã³ãããŒã©ãåãä»ããããŠããã·ã¹ãã ã«ãã¹ã ã¬ãŒãž ãšãŒãžã§ã³ããã€ã³ã¹ããŒã«ããã â ãã©ãŠã¶ãšåããªã¢ãŒã ã·ã¹ãã ã« Web ãµãŒãã¹ãã€ã³ã¹ ããŒã«ããããã«å¥ã®ã·ã¹ãã ã« RAID ã³ã³ãããŒã©ãåãä» ããã 5-3 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ãã° ã€ã³ ãã°ã€ã³ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 Adaptec Storage Manager â Browser Edition ãèµ·åããŸãã â Windows ã§ã¯ãã¹ã¿ãŒã > ããã°ã©ã > Adatec Storage Manager> Adaptec Storage Manager â Browser Edition ã® é ã«ã¯ãªãã¯ããŸãã â Linux ã®å Žåã¯ãStart > System > Adaptec Storage Manager ã®é ã«ã¯ãªãã¯ããŸãã ãã°ã€ã³ ç»é¢ã¯ã以äžã®ããã«ãªããŸãã 2 管çã·ã¹ãã ã®ãã¹ãåãŸã㯠IP ã¢ãã¬ã¹ãšããã®ã·ã¹ãã ã«ãã°ã€ã³ããããã«äœ¿çšãããŠãŒã¶åãšãã¹ã¯ãŒããå ¥åã ãŸãã 3 ãã°ã€ã³ ãã¯ãªãã¯ããŸãã ã¡ã¢ Adaptec Storage Manager ãæåã«èµ·åããæã«ã â ã€ã³ã¹ããŒã«æã«ã»ãã¥ãªãã£èªèšŒãã€ã³ã¹ããŒã«ããªãã£ã å ŽåãåããŠäœ¿çšããæã«ã€ã³ã¹ããŒã«ããå¿ èŠããããŸãã 詳现ã«ã€ããŠã¯ã5-5 ããŒãžã®ãã»ãã¥ãªãã£èªèšŒã®äœæãã ãåç §ãã ããã â ãŠãŒã¶ç»é²ãããããæ±ããããŸãã詳现ã«ã€ããŠã¯ã5-6 ããŒãžã®ããŠãŒã¶ç»é²ãããåç §ãã ããã å¥ã®ã·ã¹ãã ãã Web ãã©ãŠã¶ã䜿çšããŠãã°ã€ã³ããã«ã¯ã以 äžã®æé ã«åŸããŸãã 5-4 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš 1 Web ãã©ãŠã¶ ã¢ããªã±ãŒã·ã§ã³ãèµ·åããã¢ã¯ã»ã¹ããã·ã¹ ãã ã® IP ã¢ãã¬ã¹ãã¢ãã¬ã¹ ããŒã«å ¥åã㊠Enter ãæŒã㟠ããäŸ : https://10.6.3.14:3513/adaptec ãªã¢ãŒã ã·ã¹ãã ãžã®æ¥ç¶ã確ç«ããããšãã·ã¹ãã ãã°ã€ ã³ç»é¢ã衚瀺ãããŸãã ã¡ã¢ : ã€ã³ã¿ãŒããããžã®ã¢ã¯ã»ã¹ã«ãããã· ãµãŒã㌠ã䜿çšããŠããå ŽåãAdaptec Storage Manager Web ãµãŒããŒã«ã¢ã¯ã»ã¹ããã«ã¯ããããã· ãµãŒããŒãã〠ãã¹ããå¿ èŠããããŸãã詳现ã«ã€ããŠã¯ã4-4 ããŒãžã® ãWindows ã® ã€ã³ã¿ãŒããã ãã©ãŠã¶ã®èšå®ãããåç §ã ã ããã 2 管çã·ã¹ãã ã®ãã¹ãåãŸã㯠IP ã¢ãã¬ã¹ãšããã®ã·ã¹ãã ãžã®ãã°ã€ã³ã«é垞䜿çšãã管çè ãŠãŒã¶åãšãã¹ã¯ãŒããå ¥ åããŸãã 3 ãã°ã€ã³ ãã¯ãªãã¯ããŸãã ã»ãã¥ãªãã£èªèšŒã®äœæ Adaptec Storage Manager â Browser Edition ã®ã€ã³ã¹ããŒã«æã«ã ã»ãã¥ãªãã£èªèšŒãã€ã³ã¹ããŒã«ããªãããšãéžæããå Žåã¯ã ååèµ·åæã«ã»ãã¥ãªãã£èªèšŒãã€ã³ã¹ããŒã«ããå¿ èŠããã㟠ãã èªèšŒã¯ãæ¬¡ã®æé ã§äœæããŸãã 1 ã»ãã¥ãªãã£ã®èŠå ãŠã£ã³ããŠã衚瀺ãããããèšŒææžã®è¡š 瀺 ãã¯ãªãã¯ããŸãã 2 衚瀺ããã èšŒææž ãŠã£ã³ããŠã§ãèšŒææžã®ã€ã³ã¹ããŒã« ã㯠ãªãã¯ããŸãã 3 衚瀺ããã èšŒææžã®ã€ã³ããŒã ãŠã£ã¶ãŒã ãŠã£ã³ããŠã§ã次 ãž ãã¯ãªãã¯ããŸãã èšŒææžã®ã€ã³ããŒã ãŠã£ã¶ãŒã ãŠã£ã³ããŠã®å 容ãå€åã㟠ãã 4 èªåçã«èšŒææžã¹ãã¢ãéžæãã ã®åæå€ãåãå ¥ããæ¬¡ãž ãã¯ãªãã¯ããŸãã 5-5 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš 5 ã«ãŒãã® èšŒææžã¹ã㢠ãŠã£ã³ããŠã§ãã¯ã ãã¯ãªãã¯ã㟠ãã ããã²ãšã€ãå°ããªèšŒææžã®ã€ã³ããŒã ãŠã£ã¶ãŒã ãŠã£ã³ã ãŠã衚瀺ãããŸãã 6 OK ãã¯ãªãã¯ããŸãã æé 2 ã§èª¬æããèšŒææž ãŠã£ã³ããŠãå床衚瀺ãããŸãã 7 OK ãã¯ãªãã¯ããŸãã æé 1 ã®ã»ãã¥ãªãã£ã®èŠå ãŠã£ã³ããŠ ã«æ»ããŸããã 8 ã¯ã ãã¯ãªãã¯ããŠãèªèšŒã®äœæãšä¿åãçµäºããŸãã ãŠãŒã¶ç»é² ã»ãã¥ãªãã£èªèšŒã®ã€ã³ã¹ããŒã«ãšäœæãå®äºãããã補åãç» é²ããããæ±ããããŸããããç»é²ãã ãã¯ãªãã¯ããŠç»é²ãã ã«ã¯ãã·ã¹ãã ãã€ã³ã¿ãŒãããã«æ¥ç¶ããŠããå¿ èŠããããŸãã åŸã§ç»é²ãã ãã¯ãªãã¯ãããšãç»é²åŠçãã¹ãããã§ããŸãã åŸã§ç»é²ãã ãéžæãããšã次å Adaptec Storage Manager Browser Edition ã䜿çšãããšãã«è£œåãç»é²ããããæ±ããã㟠ãã 5-6 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš åºæ¬äºé 以äžã«ç€ºãã®ã¯ãAdaptec Storage Manager â Brower Edition ã®ä»£ 衚çãªç»é¢ã®äžäŸã§ãã ã¡ã¢ : ã䜿ãã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ããã©ãŠã¶ããã³ ã«ã©ãŒ ã¹ããŒã ã«ãã£ãŠã¯ãå³ãšå®éã®ç»é¢ã§ã¯å€å°ã®éã ãããå ŽåããããŸãã ç»é¢äžéšã«ã¯ãããã㌠ãã¬ãŒã ããããŸãããã®é åã«ã¯ãçŸ åšæ¥ç¶ããŠããã·ã¹ãã ã®ååãšãåçš®æäœãå®è¡ããã远å ã® ãŠã£ã³ããŠãéãããããããã®ãã¿ã³ãããã€ã衚瀺ãããŸãã æäœãè¡ããã¿ã³ã¯ ãã°ã¢ãŠã ãš åã¹ãã£ã³ ã§ãããã°ã¢ãŠã ãéžæãããšãã»ãã·ã§ã³ãçµäºããŠãã°ã€ã³ç»é¢ãå床衚瀺ã ããŸãã ã·ã¹ãã ã®æ§æãåã¹ãã£ã³ããã«ã¯ãåã¹ãã£ã³ ãã¿ã³ãäœ¿çš ããŸããéåžžãåã¹ãã£ã³ãå¿ èŠãªå Žå ( ã¢ã¬ã€ãäœæããåŸãª ã© ) ã«ã¯èªåçã«å®è¡ãããŸãã Adaptec Storage Manager ã«éç¥ãããã«ã·ã¹ãã æ§æã倿Žã ããããšãèããããŸããããšãã°ãAdaptec Srorage Manager ã«ãã°ã€ã³ããåŸã§ãéã€ã³ããªãžã§ã³ãåãšã³ã¯ããŒãžã£ã«å¯Ÿ ããŠãã©ã€ãã®åãä»ã / åãå€ããè¡ã£ããããšã³ã¯ããŒãžã£ ã®é»æºãå ¥ããå Žåãªã©ã§ãã æ®ãã®ãã¿ã³ â ã€ãã³ãããªãã·ã§ã³ããã«ããããããã£ãã ãã³ã¿ã¹ã¯ â ã䜿çšãããšãããã«å¥ã®ãŠã£ã³ããŠãéããŠãã è©³çŽ°ãªæ å ±ã衚瀺ãããã¹ãã¬ãŒãž ãµãã·ã¹ãã ã«é¢ãã远å ã® æäœãèšå®å€æŽãè¡ãããšãã§ããŸãã 5-7 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ããã ãã¬ãŒã ã®ããäžã«ããã³ã³ãããŒã©æ å ±ã®è¡ã«ã¯ãã·ã¹ ãã å ã§æåã«æ€åºããã Adaptec RAID ã³ã³ãããŒã©ã®ã¢ãã« çªå·ãšããã®ã³ã³ãããŒã©ã«æèŒãããŠãããã£ãã·ã¥ ã¡ã¢ãª ( ãããå Žå㯠) ã®ãµã€ãºã衚瀺ãããŸãã ã³ã³ãããŒã©æ å ±ã®äžã«ã¯ ç©ç ããã€ã¹ ãã¥ãŒãš è«ç ããã€ã¹ ãã¥ãŒããããæ¥ç¶ããŠããããã€ã¹ãšãã³ã³ãããŒã©äžã®æ¢å ã®ã¢ã¬ã€ã衚瀺ãããŸããã³ã³ãããŒã©ã®æ å ±ãšããã€ã¹ã®è¡šç€º ã¯ãã·ã¹ãã å ã®å Adaptec RAID ã³ã³ãããŒã©ã«ã€ããŠç¹°ãè¿ ãè¡ãããŸãã ã³ã³ãããŒã©ãéžæããã«ã¯ãã³ã³ãããŒã©æ å ±ã®ä»»æã®å Žæã ã¯ãªãã¯ããŸããã³ã³ãããŒã©ãéžæãããšãã€ãã³ããããã ã㣠ããã³ ã¿ã¹ã¯ ãã¿ã³ã®è²ãéãããªã¬ã³ãžè²ã«å€åããŸãã ãã®è²ã¯ããããã®ãã¿ã³ã®ãããããã¯ãªãã¯ãããšããã®ã³ ã³ãããŒã©ã«åºæã®æ å ±ãšãªãã·ã§ã³ãå«ã远å ã®ãŠã£ã³ããŠã éãããšã瀺ããŸãã ãããã¢ãã ããŒã« ãã³ã ããã€ã¹ãããã¿ã³ã®äžã«ã«ãŒãœã«ã眮ããšããããã¢ãã ã㌠ã«ã®ãã³ãã衚瀺ãããŸãããã¿ã³ã®å Žåã¯ãã¿ã³ã®æ©èœã«ã€ã ãŠã®ãã«ãæ å ±ããããã€ã¹ã®å Žåã¯è¿œå æ å ±ã衚瀺ãããŸãã ç©çããã€ã¹ ç©çããã€ã¹ ãã¥ãŒã«ã¯ãAdaptec RAID ã³ã³ãããŒã©ã«æ¥ç¶ã ããŠãããã©ã€ãããã³ãšã³ã¯ããŒãžã£ã«é¢ããæ å ±ã衚瀺ãã ãŸããåããã€ã¹ã¯æ¥ç¶å ã®ãã£ãã«ãŸãã¯ããŒãå¥ã«ãŸãšãã ããçªå·é ã«è¡šç€ºãããŸãã åãã£ãã«ã«é¢ãã衚瀺ã«ã¯ãSCSI ãã¹ã®æå€§é床ã«é¢ããæ å ±ãã³ã³ãããŒã©äžã®ãã£ãã«æ°ãããã³æ€åºãããããã€ã¹ã® æ° (SCSI ã³ã³ãããŒã©ãé€ã ) ãå«ãŸããŸãã ãã£ãã«ãŸãã¯ããã€ã¹ãéžæãããšãã€ãã³ããããããã£ã ããã³ã¿ã¹ã¯ãã¿ã³ããªã¬ã³ãžè²ã«å€ãããŸããããã¯ãããã ã®ãã¿ã³ã®ãããããã¯ãªãã¯ãããšããã®ããã€ã¹ãŸãã¯ã㣠ãã«ã«åºæã®æ å ±ãšãªãã·ã§ã³ãå«ã远å ã®ãŠã£ã³ããŠãéãã ãšã瀺ããŸãã ç©çããã€ã¹ ãã¥ãŒã®äžéšã«ã¯ã衚瀺 ã®å³åŽã« 3 ã€ã®è¡šç€ºéžæã ã¿ã³ã䞊ãã§ããŸãããããã®ãã¿ã³ã䜿çšããŠããã®ã³ã³ã ããŒã©ã«æ¥ç¶ããŠããç©çããã€ã¹ã衚瀺ããæ¹æ³ãéžæããŸãã 5-8 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ãã©ã€ãã®è¡šç€ºæ¹æ³ã®å€æŽ åæèšå®ã§ã¯ãç©çããã€ã¹ ã«ã¯ã³ã³ãããŒã©æ§æã®èŠçŽã衚瀺 ãããåãã©ã€ãã«é¢ãã詳现æ å ±ã¯å®éã«ã¯è¡šç€ºãããŸããã 詳现æ å ±ã衚瀺ããã«ã¯ãããŠã¹ ãã€ã³ã¿ãåããã€ã¹ã®äžã«çœ® ãããããã€ã¹ã®è¡ã®å·Šã«ããç¢å°ãã¯ãªãã¯ããŸãã éžæãããŠãã衚瀺ã¢ãŒã ãã¿ã³ã¯ãæ®ãã® 2 ã€ã®ãã¿ã³ããã æããéã«ãªããŸãã衚瀺ã¢ãŒãã®åæå€ã¯ ããã¹ãèšè¿°ã«ãã 衚瀺 ã§ãããAdaptec Storage Manager ã®ããŒãæã«ã¯èŠçŽè¡šç€º ã䜿çšãããããã3 ã€ã®ã¢ãŒãã®ãããã§ã衚瀺ã¯åãã«ãªã ãŸãã ä»ã®è¡šç€ºãã¿ã³ã®ãããããéžæããŠè¡šç€ºã¢ãŒãã倿Žãããšã æ å ±ããã¹ãŠè¡šç€ºãããŠããªãå Žåã¯ãèŠçŽè¡šç€ºãããŠãããã ã€ã¹ã®å·Šã«æããé»è²ã®ç¢å°ã衚瀺ãããŸãã åããã€ã¹è¡ã«ã¯ãæåã«å¿ ãã¢ã€ã³ã³ã衚瀺ãããŸãã ã¢ã€ ã³ã³ã¯ããŒããã£ã¹ã¯ ãã©ã€ãã衚ããŸããããŒããã£ã¹ã¯ ãã© ã€ã ã¢ã€ã³ã³ ã« + èšå· ãä»ããŠããå Žåããã®ãã©ã€ã㯠ããã ã¹ãã¢ã§ããç°ãªãããã€ã¹ã¯ç°ãªãã¢ã€ã³ã³ã§è¡šãã㟠ãã 衚瀺 åæå€ã®è¡šç€ºã¢ãŒã ãå±éãããšãåããã€ã¹ã«ã€ããŠä»¥äž ã®æ å ±ã衚瀺ãããŸãã â ãã©ã€ãã®å®¹é â ãã©ã€ãã®è£œé å ãšã¢ãã«çªå· â SCSI ãã©ã€ã ID ãŸãã¯ãã·ãªã¢ã« ATA ããŒãçªå· å±éãããšããã«ãµã€ãºã®å®¹é衚瀺 ãã¿ã³ ããã³ çžå¯Ÿãµã€ãº ã®å®¹é衚瀺 ãã¿ã³ ã䜿çšã§ããåãã©ã€ããããŒã§è¡šç€ºã§ã ãŸããã©ã®ã¢ã¬ã€ã«ãå±ããªããã©ã€ãã¯ãç¹ç·ã§å²ãŸããéã 圱ãä»ããŸãã ã䜿çšãããšã容éãšã¯ç¡é¢ä¿ã«ãåãã©ã€ãããšã«å¹ äžæ¯ ã®é·ãã®ããŒã衚瀺ãããŸãã ã䜿çšããå Žåãåãã©ã€ãã 衚ãããŒã衚瀺ãããŸãããæã容éã®å€§ãããã©ã€ãã®ããŒã® 5-9 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš é·ããå¹ äžæ¯ã«è¡šç€ºããããã®ä»ã®ããŒã®é·ãã¯å®¹éã®å€§ããã« æ¯äŸããŠçããªããŸãã ããŒã¯ãã¢ã¬ã€ã§äœ¿çšãããŠãããã©ã€ãã®ã»ã°ã¡ã³ããã°ã¬ãŒ ã§è¡šç€ºãããŸããã°ã¬ãŒã®ã»ã°ã¡ã³ããéžæãããšããã®ã»ã°ã¡ ã³ãã¯ãªã¬ã³ãžè²ã§ãã€ã©ã€ã衚瀺ãããè«çããã€ã¹ ãã¥ãŒã§ ã¯ãã®ã»ã°ã¡ã³ããå±ããã¢ã¬ã€ããã€ã©ã€ã衚瀺ãããŸãã ãã«ãµã€ãºã®å®¹é衚瀺 ãŸã㯠çžå¯Ÿãµã€ãºã®å®¹é衚瀺 ã®ãããã® å Žåãããã©ã€ãã®äž¡ç«¯ãäžéšããŒã¯ ã°ã¬ãŒã§è¡šç€ºãããããšã ãããŸãã ãã©ã€ãã®ç«¯ã®ã»ã°ã¡ã³ãã®ãµã€ãºã¯ãã©ã€ãããšã«ç°ãªããŸãã ããã¯ãRAID ã·ã°ããã£ã«å ããŠãåãã©ã€ãã®äœ¿çšå¯èœå®¹é ãã³ã³ãããŒã©ã«ãã£ãŠå¶éãããããã§ãã ãã®ãããªããšãè¡ãããã®ã¯ã衚é¢çã«ã¯åã容éãæã€ã㌠ããã£ã¹ã¯ ãã©ã€ãã§ã補é å ãç°ãªãå Žåããããã¯åã補é å ã®ç°ãªãã¢ãã«ã§ããå®éã«ã¯æ£ç¢ºãªäœ¿çšå¯èœå®¹éããããã« ç°ãªãããã§ãããã®ããšã¯ãéåžžã®åäœã§ã¯åé¡ã«ã¯ãªããŸã ããããããã¹ãã¢ã®å²ãåœãŠãæ éãã©ã€ãã®äº€ææã«ã¯ãå é¡ãšãªãããšããããŸãã ã³ã³ãããŒã©ãåãã©ã€ãã®æå€§å®¹éã䜿çšããŠããå Žåã«ã ããã ã¹ã㢠( ããªãã¡ä»£æ¿ãã©ã€ã ) ã®å®¹éããããããæ°ã¡ ã¬ãã€ãã§ãå°ãããã°ãæ éãã©ã€ãã眮ãæããããšã¯ã§ã ãŸããããã©ã€ãã®å®¹éã 2 MB åäœã«äžžããããšã§ããã®ãã ãªå¯èœæ§ãæé€ããããšãã§ããŸãã è«çããã€ã¹ åè¿°ã®ããã« Adaptec Storage Manager ã®ããŒãæã«ã¯è«çãã ã€ã¹ ãã¥ãŒãå±éãããŠãããããã³ã³ãããŒã©äžã«ååšãã㢠ã¬ã€ã衚瀺ããããšãã§ããŸãã At the top of this view are the following buttons: äœæã倿Žãåé€ ã®ãã¿ã³ããããŸããããããã®ãã¿ã³ã¯ã察å¿ããæ©èœã®ãŠã£ ã¶ãŒããéããŸãã 倿Žã䜿çšãããšã以äžã®æäœãå¯èœã§ãã â ã¢ã¬ã€ã® RAID ã¬ãã«ãå¥ã® RAID ã¬ãã«ã«å€æŽããã â ã¢ã¬ã€ãæ¡åŒµããã â RAID 0 ã®ã¹ãã©ã€ã ãµã€ãºã倿Žããã 5-10 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ãããã®ãã¿ã³ã®äœ¿ç𿹿³ã«ã€ããŠã¯ã5-12 ããŒãžã®ãã¢ã¬ã€ã® äœæãã5-15 ããŒãžã®ãã¢ã¬ã€ã®åé€ããããã³ 5-16 ããŒãžã®ã㢠ã¬ã€ã®å€æŽããåç §ããŠãã ããã è«çããã€ã¹ ãã¥ãŒã®äž»èŠéšåã¯ããã®ã³ã³ãããŒã©äžã®ã¢ã¬ã€ ã衚瀺ããããã«äœ¿çšãããŸããåæå€ã¯ããããã¬ãã« ã¢ã¬ã€ ã®å«ãèŠçŽè¡šç€ºã§ãã ã¡ã¢ : ãªãã·ã§ã³ ãã¿ã³ã䜿çšãããšãã³ã³ãããŒã©ã§ãµ ããŒããããŠããå Žåã¯ãã»ã«ã³ãã¬ãã« ã¢ã¬ã€ã衚瀺ã«ã ãããšãã§ããŸãã ãã®èŠçŽè¡šç€ºã§ã¯ãåããã€ã¹ã® RAID ã¬ãã«ãšããã®ããã€ã¹ ãããã ã¹ãã¢ã«ãã£ãŠä¿è·ãããŠããã©ããã衚瀺ãããŸãã ã°ããŒãã« ããã ã¹ãã¢ãèšå®ãããŠããå Žåã¯ããã®ããã ã¹ãã¢ããã¹ãŠã®ã¢ã¬ã€ãä¿è·ã§ããã ãã®å®¹éãæã£ãŠããã°ã ãã¹ãŠã®ã¢ã¬ã€ãä¿è·ãããŠãããã®ãšããŠè¡šç€ºãããŸãã å±é衚瀺ã§ã¯ãåã¢ã¬ã€ã®ã¢ã€ã³ã³ã瞊ã«äžŠã³ããã®æšªã«ã¢ã¬ã€ ã®å®¹éãååãã¿ã€ãã衚瀺ãããŸãã ã¢ã¬ã€ãã¯ãªãã¯ããŠéžæãããšã以äžã®æ å ±ããªã¬ã³ãžè²ã§ã ã€ã©ã€ã衚瀺ãããŸãã â ç©çããã€ã¹ ãã¥ãŒã«ãããŠããã®ã¢ã¬ã€ã圢æãããã¹ãŠ ã®ãã©ã€ããŸãã¯ã»ã°ã¡ã³ãã â è«çããã€ã¹ ãã¥ãŒã«ãããŠãããã ã¬ãã« ã¢ã¬ã€ã圢æã ãã»ã«ã³ã ã¬ãã« ã¢ã¬ã€ã â ããã㌠ãã¬ãŒã ã®ã€ãã³ããããããã£ãããã³ã¿ã¹ã¯ ã ã¿ã³ãããã¯ããã® 3 ã€ã®ãã¿ã³ã®ãããããéžæãããšãã ã®ã¢ã¬ã€ã«åºæã®æ å ±ãšãªãã·ã§ã³ãå«ã远å ã®ãŠã£ã³ããŠã éãããšã瀺ããŸãã 5-11 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã¢ã¬ã€ã®äœæ ã¢ã¬ã€ãäœæããåã«ãã³ã³ãããŒã©ã§ãµããŒããããã¢ã¬ã€ã® åçš®ã¿ã€ã ( ä»é² B ãåç § ) ãšãçšéã«æé©ãªã¢ã¬ã€ã®ã¿ã€ãã« ã€ããŠçè§£ããŠããå¿ èŠããããŸãã äœæ ãã¯ãªãã¯ããã¢ã¬ã€ã®äœæãŠã£ã¶ãŒããéããŸãããã® ãŠã£ã¶ãŒãã§ã¯ã以äžã®æäœãå®è¡ã§ããŸãã â åæå€ã®èšå®ã䜿çšããŠã¢ã¬ã€ãäœæããã â 詳现èšå® ãã¯ãªãã¯ããŠãŠã£ã¶ãŒããå±éãã远å ã®ãªã ã·ã§ã³ã衚瀺ããŠèšå®ãã«ã¹ã¿ãã€ãºããã åæå€ã®èšå®ã䜿çšãããšãéžæãããã©ã€ãã§å¯èœãªæå€§å®¹é ã®ã¢ã¬ã€ããåæå€ã®ãã£ãã·ã¥èšå®ãšã¹ãã©ã€ã ãµã€ãº ( é©åœ ãªå Žå ) ã䜿çšããŠäœæãããŸãã åæå€ã®èšå®ã䜿çšããŠã¢ã¬ã€ãäœæããã«ã¯ã以äžã®æé ã«åŸ ããŸãã 1 ã¢ã¬ã€ãäœæããã³ã³ãããŒã©ã«ã€ããŠ äœæ ãã¯ãªãã¯ã㊠ã¢ã¬ã€ã®äœæãŠã£ã¶ãŒããéããŸãã 2 æ§ç¯ããã¢ã¬ã€ã®ã¿ã€ããéžæããŸããæ¬¡ãž ãã¯ãªãã¯ã㟠ãã 3 ã¢ã¬ã€ã«å«ãããã©ã€ããéžæããŸããéžæãããã©ã€ãã«ãª ã¬ã³ãžè²ã®ãã§ã㯠ããŒã¯ã衚瀺ãããŸãã 4 2 å°ã®ãã©ã€ããéžæããããæ¬¡ãž ãã¯ãªãã¯ããŸãã 5 ããã§ãæ°ããã¢ã¬ã€ã«å¯ŸããŠãåæå€ã®ååã䜿çšãããã åžæã®ååãå ¥åã§ããŸããæå®ããååã®é·ãã¯æšæº ASCII æåã§æå€§ 15 æåã§ããŠããŒã¯ãªãã®ã§ãªããã°ãªããŸããã 6 å®äºãã¯ãªãã¯ããŸããã·ã¹ãã ããæ°ããã¢ã¬ã€ãäœæã㟠ããã 7 Windows 2000 ã®å Žåã®ã¿ â a ã¢ã¬ã€ã远å ããæãå®å šã§ãªãåãå€ãã®ãããã¢ãã ãçŸããŸããâ OK ãã¯ãªãã¯ããŸãã b ããã€ã¹ãããŒãžã£ãéããæ°ããã¢ã¬ã€ãèŠãããã«ã åã¹ãã£ã³ããŸãã 5-12 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš 詳现èšå® ã¢ã¬ã€ã®äœæãŠã£ã¶ãŒã㧠詳现èšå® ãã¯ãªãã¯ããŠã¢ã¬ã€ãäœæ ããå Žåã¯ãäžèšã®æé ãšåãåºæ¬ããã»ã¹ã«ãªããŸãããã³ã³ ãããŒã©ã§ãµããŒããããŠããæ©èœã«ãã£ãŠã¯ãåã¹ãããã§è¿œ å ã®ãªãã·ã§ã³ã䜿çšã§ããå ŽåããããŸãã ã¢ã¬ã€ã®äœæãŠã£ã¶ãŒã㮠詳现èšå® é åã«ä»¥äžã®ãªãã·ã§ã³ãçš æãããŠããå ŽåããããŸãã â ã¹ãã³ ããªã¥ãŒã ãš RAID ããªã¥ãŒã âãSpanned Volume ( ã¹ ãã³ ããªã¥ãŒã )ãã¯ããçšèªéãã§èª¬æãããšããè€æ°ã®ãã© ã€ãã®ã»ã°ã¡ã³ããé£çµã㊠1 ã€ã®ããªã¥ãŒã ãäœæããŸãã ãRAID Volume (RAID ããªã¥ãŒã )ãã¯ãåãã¿ã€ãã®è€æ°ã®ã¢ ã¬ã€ãé£çµããŸãã â ã©ã€ã ãã£ãã·ã¥ãæå¹ãŸãã¯ç¡å¹ã«ãã â ã©ã€ããã£ãã· ã³ã°ãæå¹ã«ãããšãã³ã³ãããŒã©ã¯ããŒã¿ãã³ã³ãããŒã©äž ã®ãã£ãã·ã¥ ã¡ã¢ãªã«ä¿åããŸããçŽåã®æžã蟌ã¿ããŒã¿ã ã³ã³ãããŒã©ã®ã¡ã¢ãªã«æ£åžžã«ä¿åããåŸãããã«ãã®ã¢ã¬ã€ ãžã®æ¬¡ã®æžã蟌ã¿ãåãå ¥ããŸãã ã¡ã¢ãªãžã®ããŒã¿ã®æžã蟌ã¿ã¯ãã©ã€ããžã®æžã蟌ã¿ããé«é ãªãããã©ã€ããã£ã·ã¥ãæå¹ã«ãããšãããã©ãŒãã³ã¹ã倧 å¹ ã«åäžã§ããŸãããã£ãã·ã¥ã«ä¿åããããã¹ãŠã®ããŒã¿ ã¯ãã³ã³ãããŒã©ã«ãšã£ãŠæãå¹çã®ããæç¹ã§ãã©ã€ãã«æž ã蟌ãŸããŸãã ! â ãæ³šæ : åæå€ã®èšå®ã§ã¯ãã©ã€ããã£ãã·ã¥ã¯æå¹ã§ ãããã®èšå®ã§ã¯ããã©ãŒãã³ã¹ãæå€§åãããŸããã 黿ºé害ãçºçããå Žåã«ããŒã¿ãæå€±ããæãããã ãŸãã ãªãŒããã£ãã·ã¥ãæå¹ãŸãã¯ç¡å¹ã«ããâãªãŒããã£ãã·ã¥ ãæå¹ã«ãããšãã³ã³ãããŒã©ã¯ãã®ã¢ã¬ã€ã«å¯Ÿããèªã¿åã ã¢ã¯ã»ã¹ãç£èŠããå°æ¥çã«èªã¿åããçºçããå Žæã®äºæž¬ã 詊ã¿ãŸãããã¿ãŒã³ãæ€åºãããå Žåã¯ã次ã«èªã¿åããè¡ã ããå¯èœæ§ãæãé«ãããŒã¿ããã³ã³ãããŒã©ã®ãã£ãã·ã¥ ã¡ã¢ãªã«ãããããããŒããããŸããã³ã³ãããŒã©ã®ã¡ã¢ãªã ãã®ããŒã¿ã®èªã¿åãã¯ãã©ã€ãããã®èªã¿åãããé«éãªã ããããã©ãŒãã³ã¹ã«å€§ããªæ¹åããããŸããåæå€ã¯ æå¹ ã§ãã 5-13 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã¢ã¬ã€ã®äœæãŠã£ã¶ãŒã㮠詳现èšå® é åã«ä»¥äžã®ãªãã·ã§ã³ãçš æãããŠããå ŽåããããŸãã â ã¢ã¬ã€ã®å®¹éã®å¶é â ãã®ãªãã·ã§ã³ã䜿çšãããšãäœæãã ã¢ã¬ã€ã®å®¹éãéžæã§ããŸããåæå€ã§ã¯ãã¢ã¬ã€ã¯ãéžæã ããã©ã€ãã§å¯èœãªæå€§ãµã€ãºã«ãªããŸããåäžã®ãã©ã€ã ã»ããäžã«è€æ°ã®ã¢ã¬ã€ãäœæããã«ã¯ããã®ãªãã·ã§ã³ã䜿 çšããŠãå°ãªããšã 1 ã€ç®ã®ã¢ã¬ã€ã®ãµã€ãºãå¶éããå¿ èŠã ãããŸãã ããšãã°ã18 GB ãã©ã€ãã 2 å°äœ¿çšã㊠9 GB ã® RAID 1 ã 2 ã€äœæããå Žåã¯ããã®ãªãã·ã§ã³ã䜿çšããŠãæåã«äœæã ãã¢ã¬ã€ã®ãµã€ãºãå¶éããŸãã ã¡ã¢ : RAID 1 ã®å®¹éã¯ãå°ãªãã»ãã®ãã©ã€ãã®å®¹éã« å¶éãããŸãã â ã¹ãã©ã€ããµã€ãºâè€æ°ã®ãã©ã€ãã«ãŸããã£ãŠããŒã¿ãã¹ã ã©ã€ãã³ã°ããã RAID 0 ã§ã¯ãã¹ãã©ã€ã ãµã€ãºã«ãã£ãŠã ã¹ãã©ã€ãã³ã°ã§åãã©ã€ãã«æžã蟌ãŸããããŒã¿éãæ±ºãŸã ãŸãã ã¡ã¢ : ã¢ããããã¯ã¯ãã¹ãã©ã€ã ãµã€ãºã®å€æŽã¯ ã㪠ã ããšããå§ãããŸãã RAID 1 ã¢ã¬ã€ã®ããã«ãåæåãå¿ èŠãªã¢ã¬ã€ã®å Žåã¯ãè©³çŽ°èš å®ãªãã·ã§ã³ã䜿çšããŠãã¢ã¬ã€ã®åæåã«äœ¿çšããæ¹æ³ã®éžæ ãšåæåã¿ã¹ã¯ã®åªå 床ã®èšå®ãè¡ãããšãã§ããŸãã ã¢ã¬ã€ã®äœæãŠã£ã¶ãŒã㮠詳现èšå® é åã«ä»¥äžã®åæåã®ãªã ã·ã§ã³ãçšæãããŠããå ŽåããããŸãã â æ§ç¯ âRAID 1 ã§ã¯ããã©ã€ã㪠ãã©ã€ãã®ããŒã¿ããã»ã«ã³ ã㪠ãã©ã€ãã«ã³ããŒãããŸãã ã¢ã¬ã€ã®æ§ç¯ã®é·æã¯ãã¢ã¬ã€ãããã«äœ¿çšå¯èœã«ãªãããš ãšãæ§ç¯ãå®äºããã°ã¢ã¬ã€ãæå€§ã®ããã©ãŒãã³ã¹ã§åäœã ãããšã§ãããã ããæ§ç¯ã«æéããããããš ( å€§èŠæš¡ãªã¢ã¬ ã€ã§ã¯äœæéããããããšããããŸã ) ãšãæ§ç¯ãå®äºãã㟠ã§ããã©ãŒãã³ã¹ã«åœ±é¿ããããšãã£ãçæããããŸãã 5-14 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš â ã¯ãªã¢ â ãã®å Žåããã¹ãŠã®ãã©ã€ãã®å å®¹ãæ¶å»ãããŸãã ã¢ã¬ã€ã®ã¯ãªã¢ã®é·æã¯ãæ§ç¯ãããåŠçãéãããšãšãã¯ãª ã¢ãå®äºããã°ã¢ã¬ã€ãæå€§ã®ããã©ãŒãã³ã¹ã§åäœããããš ã§ãããã ããã¯ãªã¢ãå®äºãããŸã§ã¢ã¬ã€ã«ã¢ã¯ã»ã¹ã§ã㪠ããšããçæããããŸãã â ã¯ã£ã㯠â ãã®å Žåãã¢ã¬ã€ã¯ããã«äœ¿çšã§ããŸããã¯ã€ã㯠ã«ããåæåã®é·æã¯ãã¢ã¬ã€ãããã«äœ¿çšå¯èœã«ãªãç¹ã§ã ( æ§ç¯ãåæé²è¡ããªããã )ã â åæååªå 床 â ãã®ããããããŠã³ ãªã¹ãã䜿çšããŠãåæ åã¿ã¹ã¯ã®åªå 床ã調æŽã§ããŸããåæå€ã®èšå®ã¯ é« ã§ãå æåãå¯èœãªãããéãå®äºãããŸãããã®ä»ã«ã¯ äž ãš äœ ã® ãªãã·ã§ã³ããããŸããã³ã³ãããŒã©ã§ä»ã«ã©ã®ãããªã¿ã¹ã¯ ãå®è¡ãããŠãããã«ãã£ãŠããããã®ãªãã·ã§ã³ãéžæãã ãšåæåã«ãããæéãé·ããªãããšããããŸãã ã¢ã¬ã€ã®åé€ ã¡ã¢ : ã¢ã¬ã€ãåé€ãããšãã¢ã¬ã€äžã®å šãŠã®ããŒã¿ãå£ã ãŸããå§ããåã«ãå¿ ãããŒã¿ã®ããã¯ã¢ãããè¡ã£ãŠãã ããã ã¢ã¬ã€ãåé€ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 è«çããã€ã¹ ãã¥ãŒã§åé€ ãã¿ã³ãã¯ãªãã¯ããŸãã 2 è«çããã€ã¹ ãã¥ãŒã§ãåé€ããã¢ã¬ã€ãéžæããŸãã 3 å®äº ãã¯ãªãã¯ããŸããæ£ããã¢ã¬ã€ãåé€ããŠãããç¢ºèª ããæ©äŒãæäŸããèŠåã¡ãã»ãŒãžãçŸããŸãã 4 åæå€ã¯ ã¯ã ã§ãã 5 Windows 2000 ã®å Žåã®ã¿ â a ã¢ã¬ã€ã远å ããæãå®å šã§ãªãåãå€ãã®ãããã¢ãã ãçŸããŸããâ OK ãã¯ãªãã¯ããŸãã b ããã€ã¹ãããŒãžã£ãéãã倿ŽãèŠãããã«ãåã¹ã㣠ã³ããŸãã 5-15 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã¢ã¬ã€ã®å€æŽ ãã®æ©èœããµããŒãããã³ã³ãããŒã©ã§ãå€æŽ ã䜿çšãããšãæ¢ åã®ã¢ã¬ã€ã«å¯ŸããŠä»¥äžã®å€æŽãè¡ãããšãã§ããŸãã â ã¢ã¬ã€ãå¥ã® RAID ã¬ãã«ã«ãã€ã°ã¬ãŒã·ã§ã³ ( ç§»è¡ ) ããã â ã¢ã¬ã€ã®å®¹éãæ¡åŒµããã â ã¹ãã©ã€ã ãµã€ãºã倿Žããã Windows 2000 ã Windows XP ãªã©ãäžéšã®ãªãã¬ãŒãã£ã³ã° ã· ã¹ãã ã«ã¯ããªã³ã©ã€ã³å®¹éæ¡åŒµ (OCE:Online Capacity Expansion) ããµããŒãããŠãããã®ããããŸãããã®å Žåãã¢ã¬ ã€ã®æ¡åŒµãå®äºããæç¹ã§ãã·ã¹ãã ã®åèµ·åãè¡ããã«è¿œå éš åã®å®¹éã䜿çšã§ããŸãã远å ãã容éã®äœ¿çšã«ã€ããŠã¯ãã䜿 ãã®ãªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã®èª¬ææžãåç §ããŠãã ããã ãã€ã°ã¬ãŒã·ã§ã³ã«ã¯ä»¥äžã®èŠåãé©çšãããŸãã 1 æ°ããã¢ã¬ã€ã®å®¹éã¯ãçŸåšã®ã¢ã¬ã€ã®å®¹éãšåããããä»¥äž ã§ãªããã°ãªããŸããã 2 æ°ããã¢ã¬ã€ã®å®¹éãŸã㯠RAID ã¿ã€ããå¿ èŠãšãããã©ã€ã 容éã®åèšãçŸåšã®ã¢ã¬ã€ããå€ãå Žåã¯ããã©ã€ãäžã«ãçŸ åšã®ã¢ã¬ã€ã§äœ¿çšãããŠããªã远å ã®å®¹éãå¿ èŠã§ãã ã¢ã¬ã€ã倿Žããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 å€æŽ ãã¯ãªãã¯ããŸãã 2 倿Žããã¢ã¬ã€ãéžæããŸãã 3 ã¢ã¬ã€ããã€ã°ã¬ãŒã·ã§ã³ãã RAID ã¬ãã«ãéžæããããæ¢ åã®ã¢ã¬ã€ã®å®¹éãæ¡åŒµããå Žåã¯çŸåšã® RAID ã¬ãã«ãéžæ ããŸãã 4 å¿ èŠã«å¿ããŠã容éã®æ¡åŒµãŸãã¯æ°ãã RAID ã¬ãã«ã®ãµã㌠ãã«å¿ èŠãªè¿œå ã®ãã©ã€ããéžæããŸãã 詳现èšå® ãã¯ãªãã¯ããã¿ã¹ã¯ã®åªå 床ã調æŽããŸã ( ãªã ã·ã§ã³ )ã 5 å®äº ãã¯ãªãã¯ããŸãã 5-16 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ãŠãŒã¶ ã€ã³ã¿ãŒãã§ã€ã¹ ãªãã·ã§ã³ ãªãã·ã§ã³ ãã¯ãªãã¯ããŠããŠãŒã¶ ã€ã³ã¿ãŒãã§ã€ã¹ã倿Žã§ã ãŸãããããããŠã³ ãªã¹ãã®ããããã§æ°ããéžæãããšãå€æŽ ãããã«é©çšãããŸãã 以äžã®å€æŽãå¯èœã§ãã â ã»ã«ã³ãã¬ãã«ã¢ã¬ã€ â åæå€ã§ã¯ãè«çããã€ã¹ ãã¥ãŒã® ã»ã«ã³ã ã¬ãã« ã¢ã¬ã€ã¯é ããŠããŸããã»ã«ã³ã ã¬ãã« ã¢ã¬ ã€ã衚瀺ããããã«éžæããããšãã§ããŸãã â ããã¯ã°ã©ãŠã³ãã§ã®æŽæ°ã®é »åºŠ â ãã®ãªãã·ã§ã³ã¯ãWeb ãµãŒããŒã«ããŒãªã³ã°ããŠæŽæ°ãããæ§ææ å ±ã調ã¹ãé »åºŠã èšå®ããŸããåæå€ã¯ 30 ç§ã§ãããã®ä»ã«ã15 ç§ã1 åã5 åããéžæã§ããŸãã â ããŠã¹ã«ãããã€ã©ã€ã â ã«ãŒãœã«ãç§»åãããšãã³ã³ãã㌠ã©ããã£ãã«ãããã€ã¹ããŸãã¯ã¢ã¬ã€ããªã¬ã³ãžã®ããã¯ã¹ ã§å²ãŸããããšããããŸãããã®ãã€ã©ã€ã衚瀺ã¯ãããŠã¹ã« ãããã€ã©ã€ã ã®ããããããŠã³ ãªã¹ãã§ ããã ãéžæã ãŠãç¡å¹ã«ã§ããŸãã â ãããã¢ãã ããŒã«æ å ± â ç»é¢ã§ããŠã¹ ã«ãŒãœã«ãç§»åãã ãšãããã€ã¹ãŸãã¯ãã¿ã³äžã«ã«ãŒãœã«ã眮ããéã«ããã ã¢ãã ããŒã«æ å ±ã衚瀺ãããããšããããŸãããã¿ã³ã®å Ž åã¯ãã¿ã³ã®æ©èœã«ã€ããŠã®ãã«ãæ å ±ãå«ãŸããæ©åšã®å Žå ã¯è¿œå æ å ±ã衚瀺ãããŸãã ããŒã«æ å ±ã®è¡šç€ºã¯åæå€ã§ã¯æå¹ã§ãå°ãæéããããŠè¡šç€º ãããããã«èšå®ãããŠããŸããããŒã«æ å ±ã®è¡šç€ºãç¡å¹ã«ã ããªãããã«ãããã¢ããããããã«æå®ã§ããŸãã å³äžã³ãŒããŒã® X ãã¯ãªãã¯ããŠãŠã£ã³ããŠãéããŸãã 5-17 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã€ãã³ãã®è¡šç€º ã€ãã³ã ãã¿ã³ã䜿çšãããšãã·ã¹ãã å ã®ãµããŒããããŠãã ãã¹ãŠã®ã³ã³ãããŒã©ã®ã€ãã³ãã衚瀺ããã³ã€ãã³ãéç¥ãèš å®ã§ããŸãã ã€ãã³ããã¥ãŒã¢ åã€ãã³ãã«ã€ããŠã以äžã®æ å ±ã衚瀺ã§ããŸãã â ã€ãã³ãã®æ¥æ â ã€ãã³ãã®éèŠåºŠ â çã説æ ã€ãã³ãè¡šç€ºéžæ ã®åæå€ã¯ ãå šãŠãã«èšå®ãããŠãããã䜿ã ã®ã³ã³ãšããŒã©ã§äœ¿çšå¯èœãªå šã¬ãã«ã®ã€ãã³ãã衚瀺ããŸãã ããããããŠã³ ãªã¹ãã䜿çšããŠãèŠåããã³é倧ã¬ãã«ã®ã€ã ã³ãã®ã¿ ( èŠå (Warning))ããŸãã¯é倧ãªã€ãã³ãã®ã¿ ( é倧 (Critical)) ã衚瀺ããããã«éžæã§ããŸãã ç»é¢ã®äžéšã«ã€ãã³ã ãã°ãã¯ãªã¢ãããã¯ãªã¢ ãã¿ã³ããã㟠ãã ã€ãã³ãéç¥ ã³ã³ãããŒã©ã®ã€ãã³ããã·ã¹ãã ã®ã€ãã³ã ãã°ã«è¿œå ããã ãšã®ã§ããéç¥ãµãŒãã¹ãçšæãããŠããŸãããã®ãµãŒãã¹ãå© çšããŠãã³ã³ãããŒã©ã®ã€ãã³ããç»é¢äžã«ãããã¢ãã ã¡ã ã»ãŒãžã§è¡šç€ºããããšãããŠãŒã¶ãŒã«é»åã¡ãŒã«ã§éç¥ããããš ãã§ããŸããåæå€ã¯ åäœäž ã§ãã éç¥ãµãŒãã¹ã®ã€ãã³ã ã¬ãã« ã»ãšãã©ã® Adaptec ã³ã³ãããŒã©ã¯ã3 çš®é¡ã®ã€ãã³ã ã¬ãã«ã ãµããŒãããŸãã â é倧 (Critical) â èŠå (Warning) â æ å ± (Information) - ãã®ã¬ãã«ã¯ãµããŒããããŠããªãå Žåã ãããŸãã ã·ã¹ãã ãã°ã«è¿œå ãããã€ãã³ãã®ã¬ãã«ãšãåãŠãŒã¶ãŒãå ãåãã¬ãã«ã¯ãåå¥ã«èšå®ã§ããŸãã 5-18 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš éç¥ãµãŒãã¹ã®æå¹åãšèšå® é»åã¡ãŒã«éç¥ãæ§æããåã«ãæ¬¡ã®æ å ±ã確èªããŠãããŠãã ããã â SMTP ã¡ãŒã« ãµãŒãã®ãã¹ãåãŸã㯠IP ã¢ãã¬ã¹ã â SMTP ã¡ãŒã« ãµãŒãã䜿çšããããèšå®ãããŠããããŒãåæ å€ã¯ 25 (SMTP ã¡ãŒã« ãµãŒã ããã±ãŒãžã®å€ããåæå€ãšã㊠䜿çšããŠãã ) ã«èšå®ãããŠããŸããåæå€ãäžæã®å Žåã¯ã é»åã¡ãŒã«ç®¡çè ã«ç¢ºèªããŠãã ããã â è¿ä¿¡ãããŠããé»åã¡ãŒã«ã®è»¢éå ãšãªã SMTP é»åã¡ãŒã« ã¢ãã¬ã¹ãSMTP é»åã¡ãŒã« ã¢ãã¬ã¹ã¯ã myname@companyname.com ãšãã圢åŒã«ãªããŸãã â ã€ãã³ãéç¥ãåãåãå¿ èŠã®ãããã¹ãŠã®ãŠãŒã¶ã® SMTP é» åã¡ãŒã« ã¢ãã¬ã¹ã ã€ãã³ãéç¥ã®èšå® ã€ãã³ãéç¥ãèšå®ããã«ã¯ä»¥äžã®æé ã«åŸããŸãã 1 ã·ã¹ãã ãã° ãã«ããŠã³ã䜿çšããŠãã·ã¹ãã ã€ãã³ã ãã° ã«è¿œå ããã€ãã³ãã®ã¬ãã«ãéžæããŸãã 2 ãããã¢ããèŠå ãã«ããŠã³ã䜿çšããŠããããã¢ãã ã¡ã ã»ãŒãžã衚瀺ããã€ãã³ãã®ã¬ãã«ãéžæããŸãããŸãã¯ãã· ã¹ãã ãµãŠã³ãã§éç¥ããããèšå®ããã«ã¯ãèŠåé³ãªã³ ããã¯ã¹ãéžæããŸãã é»åã¡ãŒã«éç¥ãèšå®ããã«ã¯æ¬¡ã®ããã«ããŸãã 3 SMTP ãµãŒã ã«ãSMTP ã¡ãŒã« ãµãŒãã®ãã¹ãåãŸã㯠IP 㢠ãã¬ã¹ãå ¥åããŸãã 4 ããŒãçªå· ã«ãSMTP ã¡ãŒã« ãµãŒãã䜿çšããããèšå®ãã ãŠããããŒãçªå·ãå ¥åããŸãã 5 è¿éã¡ãŒã« ã«ãé»åã¡ãŒã«ã®è¿ä¿¡å ãšããŠæå®ããé»åã¡ãŒ ã« ã¢ãã¬ã¹ãå ¥åããŸãã 6 éç¥ã®åä¿¡ãããŠãŒã¶ã®é»åã¡ãŒã« ã¢ãã¬ã¹ãå ¥åããŸãã ãã®ãŠãŒã¶ãåãåãã€ãã³ãã®ã¬ãã«ãéžæããŸããä»ã® ãŠãŒã¶ã远å ããã«ã¯ãäžèšã®æé ãç¹°ãè¿ããŸãã 5-19 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã¡ã¢ : 4 人以äžã®ãŠãŒã¶ã«éç¥ããå¿ èŠãããå Žåã¯ãé»å ã¡ãŒã«ã®ã°ã«ãŒãã¢ãã¬ã¹ãäœæããããšããå§ãããŸãã 倿Žã®é©çš ã€ãã³ãéç¥ ã¿ã ã§å€æŽã§ããŸãã倿Žå¯èœãªãã£ãŒã«ããéžæ ãããšã倿Žãä¿åããããã«ãé©çš ãã¿ã³ã ãã£ã³ã»ã« ãã¿ ã³ãéžæããŸãã ãã«ãã®äœ¿çš ãã«ã ãã¯ãªãã¯ãããšããã®ã¢ããªã±ãŒã·ã§ã³ããã¯ãã«ã« ãµ ããŒããã»ãŒã«ã¹ã®åã¿ããå«ãç»é¢ã衚瀺ãããŸãã ãã®ã¢ããªã±ãŒã·ã§ã³ ã¿ããã¯ãªãã¯ãããšãã¢ããªã±ãŒã·ã§ã³ ã®ååãšããŒãžã§ã³ã«é¢ããæ å ±ãšããªã³ã©ã€ã³ ãã«ããžã®ãªã³ ã¯ã衚瀺ãããŸãã ãã¯ãã«ã« ãµããŒã ã¿ããã¯ãªãã¯ãããšãAdaptec ãã¯ãã«ã« ãµããŒãã® Web ãµã€ããžã®ãªã³ã¯ã衚瀺ãããŸãã ã»ãŒã«ã¹ ã¿ããã¯ãªãã¯ãããšãAdaptec å¶æ¥éšéã®é»è©±çªå·ãš 補åã®ãè³Œå ¥ã«ã€ããŠã® Web ãµã€ããžã®ãªã³ã¯ã衚瀺ãããŸãã ããããã£ã®è¡šç€ºãšå€æŽ ãããã㣠ãã¯ãªãã¯ãããšãã³ã³ããŒãã³ãã«é¢ãã詳现æ å ± ã衚瀺ãããŸããç¹å®ã®ã³ã³ãããŒã©ããã£ãã«ãããã€ã¹ã㢠ã¬ã€ã«ã€ããŠã®ããããã£ã衚瀺ããã«ã¯ããã®é ç®ãéžæã㊠ãããã㣠ãã¯ãªãã¯ããŸãã ãããã㣠ãã¿ã³ããªã¬ã³ãžè²ã®å Žåã¯ãã¯ãªãã¯ãããšãŠã£ã³ ããŠãéããéžæãããŠããé ç®ã«é¢ãã詳现æ å ±ãšãªãã·ã§ã³ ã衚瀺ãããŸããããããã£ãéã®å Žåã¯ãã¯ãªãã¯ãããšãæ¥ ç¶ããŠããã·ã¹ãã ã®ãã¹ãåã衚瀺ãããŸãã ã³ã³ãããŒã©ã®ãããã㣠ã³ã³ãããŒã©æ å ±ãèŠããã倿Žããã«ã¯ãã³ã³ãããŒã©ãéžæ ã㊠ãããã㣠ãã¯ãªãã¯ãããšãã³ã³ãããŒã©æ å ±ãã¢ã©ãŒ ã ãããããªãããã³è©³çް ã®åã¿ããå«ããŠã£ã³ããŠã衚瀺ãã ãŸãã 5-20 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã³ã³ãããŒã©æ å ± éžæããã³ã³ãããŒã©ã«ã€ããŠã以äžã®æ å ±ãäžèŠ§è¡šç€ºãããŸãã â ã¢ãã« âAdaptec 瀟ã®ã¢ãã«çªå·ãåã³ã³ãããŒã©ã®ã¡ã€ã³ç» é¢ã«ã衚瀺ãããŸãã â ã·ãªã¢ã«çªå·âã䜿ãã®ã³ã³ãããŒã©ãèå¥ãããŠããŒã¯ãªçª å·ã â ãã¹ããã¹âãã®ã³ã³ãããŒã©ãæ¥ç¶ãããŠãããã¹ã®ã¿ã€ã ãšçªå·ã â ã¡ã¢ãªãµã€ãº âAdapetc 1210SA ã§ã¯å©çšã§ããŸããã â ãã£ãã·ã¥ãµã€ãº âAdapetc 1210SA ã§ã¯å©çšã§ããŸããã â ãã£ãã« / ããŒãæ° â ãã®ã³ã³ãããŒã©ã®ãã£ãã«ãŸãã¯ããŒ ãæ° (SCSI ãŸã㯠ATA) ãŸãã¯ããŒãæ° (SATA)ã 詳现 ãã®ãŠã£ã³ããŠã«ã¯ããã®ã³ã³ãããŒã©ã®ããã€ãã®ã³ã³ããŒã ã³ãã®è©³çްæ å ±ãäžèŠ§è¡šç€ºãããŸãã â ã¢ãã¿ãã«ãŒãã«ãBIOS ããŒãžã§ã³ â ã³ã³ãããŒã©ã«ããŒã ãããŠããããŸããŸãªãœãããŠã§ã¢ ã³ã³ããŒãã³ãã®ã㌠ãžã§ã³çªå·ãã³ã³ãããŒã©ã«ãã£ãŠã¯ã3 ã€ã®ã³ã³ããŒãã³ã å šãŠããããšã¯éããŸããã â ããŒããŠã§ã¢ ããŒãžã§ã³ â ã³ã³ãããŒã© ããŒããŠã§ã¢ã®ã㌠ãžã§ã³ ã¬ãã«ã â ããã»ããµã¿ã€ãåã³ã¹ããŒã âAdapetc 1210SA ã§ã¯å©çšã§ ããŸããã ãã£ãã«ãšããŒãã®ãããã㣠ãã£ãã«ãããŒãã®ããããã£ãèŠãã«ã¯ããã£ãã«ãéžæã㊠ãããã㣠ãã¯ãªãã¯ãããšã以äžã®æ å ±ãå«ãã¿ãã 1 ã€ãã ãã€ã¢ãã° ããã¯ã¹ã衚瀺ãããŸãã â ãã£ãã« ã¿ã€ã / ããŒã ã¿ã€ã â éžæããŠãããã£ãã«ãŸã㯠ããŒãã SCSI ã ATA ã Serial ATA ãã瀺ããŸãã â æå€§ãïŒã¿ã¬ãŒãâãã®ãã£ãã«ã§ã®æå€§ã®ããŒã¿è»¢éã¬ãŒã (320 MB/ ç§ãªã© )ã 5-21 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ç©çããã€ã¹ã®ãããã㣠ãã£ãã«äžã®ããã€ã¹ ( ãšã³ã¯ããŒãžã£ãé€ã ) ãéžæã㊠ãã ãã〠ãéžæãããšããã©ã€ãæ å ±ã容éãLEDãããã³ S.M.A.R.T. ã®åã¿ããä»ãããŠã£ã³ããŠã衚瀺ãããŸãã ãã©ã€ãæ å ± â ã¹ããŒã¿ã¹ â ãã®ãã£ãŒã«ãã¯ãã£ã¹ã¯ ãã©ã€ãã«ã€ããŠã® ã¿è¡šç€ºããããã©ã€ãã®çŸåšã®ã¹ããŒã¿ã¹ã瀺ããŸãã衚瀺ã ããå€ã¯ãæ£åžž (Optimal)ãæ é (Failed)ãäžæ (Phantomãç© ççã«èŠã€ãããªã )ãS.M.A.R.T.ãèŠå (Warning)ãäžæ (Unknown)ããªã (Missing) ã§ãã â ã¿ã€ã â ããã€ã¹ã®ã¯ã©ã¹ ( ããšãã°ããã£ã¹ã¯ ãã©ã€ãã CD-ROMãã¹ãã£ããããªã³ã¿ãªã© )ã â 補å â ããã€ã¹ã®è£œé å ã«ããããã€ã¹ã®åç§°ã â 補é å â ãã®ããã€ã¹ã®è£œé å ã â ãªããžã§ã³ â ããã€ã¹ã«æ ŒçŽãããŠããããŒãžã§ã³çªå·æ å ±ã â ããŒã¿ã¬ãŒãâãã®ããã€ã¹ãšã³ã³ãããŒã©ã®æå€§ããŒã¿è»¢é é床ã â SCSI IDãLUNâSCSI ãã£ãã«äžã®ããã€ã¹ã®å Žåã¯ããã ã€ã¹ã® SCSI ID ãš LUN ã衚瀺ãããŸãããããã¯ãATA ãã· ãªã¢ã« ATA ã®ããã€ã¹ã«ã¯åœãŠã¯ãŸãããåžžã« 0 ãè¿ããŸãã 容é 容éã¿ãã¯ããã£ã¹ã¯ ãã©ã€ãã«ã€ããŠã®ã¿è¡šç€ºãããŸãããã® ã¿ããéžæãããšããã©ã€ãã®äºçŽå®¹éã䜿çšå®¹éã䜿çšå¯èœå®¹ éãåèšå®¹éã®äžèЧã瀺ããµããªãŒã衚瀺ãããŸãã ãããã®å®¹éã¯ã512 ãã€ãã®ãããã¯æ° (10 鲿°å€ãš 16 鲿°å€ ã§è¡šç€ºãããŸã ) ãšããããã€ããã¡ã¬ãã€ããã®ã¬ãã€ãã®ã ãããã®åäœã§è¡šç€ºãããŸãã 詳现ãªãã·ã§ã³ãéžæãããšããã©ã€ãã®ãã¹ãŠã®ã»ã°ã¡ã³ãã« é¢ããæ å ±ã衚瀺ãããŸããããã§ã¯ãåã»ã°ã¡ã³ãã«ã€ããŠä»¥ äžã®æ å ±ã衚瀺ãããŸãã â ã»ã°ã¡ã³ãã®çªå· â éå§ããã³çµäºããã㯠5-22 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš â ã»ã°ã¡ã³ãã®ãµã€ãºãšã¿ã€ã ã¿ã€ãã¯ãã»ã°ã¡ã³ãã®äœ¿ç𿹿³ã瀺ããŸããæåãšæåŸã®ã»ã° ã¡ã³ãã¯äºçŽãããŠããŸããã³ã³ãããŒã©ã¯ããã©ã€ãã®æå㟠ãã¯æåŸã« RAID ã·ã°ããã£ãæ ŒçŽãããŸãããã©ã€ãã®ç«¯ã®ã» ã°ã¡ã³ãã§ã¯ã容éã 2 MB åäœã§äžžããããå¯èœæ§ããããŸãã ã»ã°ã¡ã³ããã¢ã¬ã€ã«å±ããå Žåã¯ãã¿ã€ãã¯ããã®ã»ã°ã¡ã³ã ã䜿çšãããŠããã¢ã¬ã€ã®ã¬ãã«ã瀺ããŸããã»ã°ã¡ã³ããã¢ã¬ ã€ã§äœ¿çšãããŠããããäºçŽé åã§ããªãå Žåã¯ã䜿çšå¯èœãšã ãŠè¡šç€ºãããŸãã åæå€ã§ã¯ã詳现æ å ±ã®ãã¥ãŒã«è¡šç€ºãããåã»ã°ã¡ã³ãã®éå§ ãããã¯ãšçµäºãããã¯ã®çªå·ã¯ã10 鲿°å€ã§ç€ºãããŸããã ãããããŠã³ ãªã¹ãã䜿çšããŠããããã®çªå·ã 16 鲿°ãŸã㯠容éã§è¡šç€ºããããã«èšå®ã§ããŸãã S.M.A.R.T. S.M.A.R.T. ã®éå®³äºæž¬ã¬ããŒãããµããŒã ããŠããããŒããã£ã¹ 㯠ãã©ã€ãã®å Žåã¯ããã®è¿œå ã®ã¿ãã衚瀺ãããŸãããã®ã¿ã ã«ã¯ä»¥äžã®ãšã³ããªãå«ãŸããŸãã â æå¹ â ãã®ããã€ã¹ã§ S.M.A.R.T. ã¬ããŒããæå¹ãã©ããã 瀺ããŸãã â æ éã®åå ãšãªãçŸè±¡ã®çºç â ãã®ããã€ã¹ãéå®³äºæž¬ã㬠ããŒãããŠãããã©ããã瀺ããŸãã LED ãã®ã¿ãã¯ãåããŒããã£ã¹ã¯ ãã©ã€ãã«ã€ããŠè¡šç€ºãããLED ç¹æ» ãš å šãŠã®ç¹æ» ã®åæ¢ ã® 2 ã€ã®ãã¿ã³ããããŸãã â LED ç¹æ» â ãã®ãã¿ã³ãã¯ãªãã¯ãããšãéžæãããããã€ã¹ ã®ã¢ã¯ã»ã¹ LED ãç¹æ» ããŸãããã®ãã¿ã³ã䜿çšããŠãã©ã€ ããèå¥ããŸããã¢ã¯ã»ã¹ LED ã®ç¹æ» ã¯ å šãŠã®ç¹æ» ã®åæ¢ ã ã¯ãªãã¯ãããŸã§ç¶ããŸãã â å šãŠã®ç¹æ» ã®åæ¢ â ãã®ãã¿ã³ãã¯ãªãã¯ãããšããã¹ãŠã®ã ã©ã€ãã«ã€ããŠãLED ç¹æ» ãã¿ã³ã®å¹æãåãæ¶ãããŸãã 5-23 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ãšã³ã¯ããŒãžã£ã®ãããã㣠ãšã³ã¯ããŒãžã£ãéžæã㊠ãããã㣠ãã¯ãªãã¯ãããšãäžè¬ä» æ§ããã¡ã³ãPSUãæž©åºŠãããã€ã¹ ããã³ ã¹ããŒã« ã®åã¿ãã å«ãç»é¢ã衚瀺ãããŸãã äžè¬ä»æ§ äžè¬ä»æ§ ã¿ãã«ã¯ä»¥äžã®æ å ±ã衚瀺ãããŸãã â 補é å â ãšã³ã¯ããŒãžã£ã®è£œé å ã â 補å â 補é å ã«ãããšã³ã¯ããŒãžã£ã®åç§°ã â ãªããžã§ã³âãšã³ã¯ããŒãžã£ã«æ ŒçŽãããŠããããŒãžã§ã³çªå· æ å ±ã â ã¹ããŒã¿ã¹ ãµããªãŒ â ãšã³ã¯ããŒãžã£ã®ãã¡ã³ãPSUãæž©åºŠ ã»ã³ãµãŒã®ã¹ããŒã¿ã¹ã®æŠèŠã瀺ããŸãã åã³ã³ããŒãã³ãã®è©³çްã¯ãé¢é£ããã¿ãã§è¡šç€ºã§ããŸãã ãã¡ã³ãš PSU ãã¡ã³ã¿ããš PSU ( 黿ºãŠããã ) ã¿ãã«ã¯ããšã³ã¯ããŒãžã£å ã®ãã¹ãŠã®ãã¡ã³ /PSU ãšãã®ã¹ããŒã¿ã¹ãã©ã³ãã ãªé åºã§äž 芧衚瀺ãããŸãã æž©åºŠ 枩床 ã¿ãã«ã¯ããšã³ã¯ããŒãžã£å ã®ãã¹ãŠã®æž©åºŠã»ã³ãµãŒãã©ã³ ãã ãªé åºã§äžèŠ§è¡šç€ºãããŸããåã»ã³ãµãŒã«ã€ããŠãçŸåšã®æž© 床ãšã¹ããŒã¿ã¹ã衚瀺ãããŸãã æž©åºŠãè¯æ°ãšææ°ã®ã©ã¡ãã§è¡šç€ºããããéžæã§ããŸãã ããã€ã¹ ããã€ã¹ ã¿ãã«ã¯ããšã³ã¯ããŒãžã£å ã®ã¹ããããã©ã³ãã ãªé åºã§äžèŠ§è¡šç€ºãããŸããåã¹ãããã«ã€ããŠãååšããããã€ã¹ ã® SCSI ID ãšãã®çŸåšã®ã¹ããŒã¿ã¹ã衚瀺ãããŸãã ã¹ããŒã« ã¹ããŒã« ã¿ãã«ã¯ããšã³ã¯ããŒãžã£ã«ã¹ããŒã«ãè£ åãããŠãã ãã©ããã瀺ãããŸãã 5-24 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã¹ããŒã«ãè£ åãããŠãããšã³ã¯ããŒãžã£ã®å Žåã¯ãé³å£°åæ¢ ã ã¿ã³ã衚瀺ãããŸãããã®ãã¿ã³ã䜿çšãããšãé害ãçºçãã å Žåã«ã¹ããŒã«ããªãã«ããããšãã§ããŸãã è«çããã€ã¹ã®ãããã㣠è«çããã€ã¹ãéžæã㊠ãããã㣠ãã¯ãªãã¯ãããšãè«çãã© ã€ã ã¿ããš ãã£ã·ã¥ ã¿ããå«ãç»é¢ã衚瀺ãããŸãã è«çãã©ã€ã è«çãã©ã€ãæ å ± ã¿ãã«ã¯ä»¥äžã®æ å ±ã衚瀺ãããŸãã â ã¹ããŒã¿ã¹ â 衚瀺ãããå€ã¯ã ãQuick Init ( ã¯ã€ãã¯åæå )ãã ãImpacted ( ã€ã³ãã¯ã )ãã ãDegraded ( ãã°ã¬ãŒã )ãã ãFailed ( æ é )ãããšãªãã©ã€ã³ ã§ãã â åå â ãã®ãã£ãŒã«ãã¯å€æŽã§ããŸããã¢ã¬ã€ã®äœææã«æ å®ãããååã衚瀺ãããŸããåå ãã£ãŒã«ããã¯ãªãã¯ãã 15 æåãŸã§ã® æšæº ASCII æåã䜿çšããŠã¢ã¬ã€ã®ååãå€æŽ ã§ããŸãã â ã¿ã€ã â éžæããã¢ã¬ã€ã® RAID ã¬ãã«ãŸãã¯ããªã¥ãŒã ã¿ ã€ãã â 容éâéžæããã¢ã¬ã€ã®ç©ç容éãã®ã¬ãã€ãåäœã§è¡šç€ºãã ãŸããæ¬åŒ§å ã«ã¯ãããã¯æ°ã衚瀺ãããŸãã â ã¹ãã©ã€ããµã€ãº â éžæããã¢ã¬ã€ã®ã¹ãã©ã€ã ãµã€ãº ( ã¹ã ã©ã€ããé©çšãããå Žå )ã â ãããã¹ã㢠â åé·ã¢ã¬ã€ã®å Žåã¯ãéžæããã¢ã¬ã€ãããã ã¹ãã¢ã§ä¿è·ãããŠãããã©ããã衚瀺ãããŸãã â è«çãã©ã€ãçªå· â ã³ã³ãããŒã©ã«ãã£ãŠãéžæããã¢ã¬ã€ã« å²ãåœãŠãããçªå·ããã®çªå·ã¯ã³ã³ãããŒã©ã§ã®ã¿äœ¿çšãã ãŸãã 5-25 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš ã¿ã¹ã¯ã®è¡šç€ºãšäœæ ã¿ã¹ã¯ ãã¿ã³ã¯ã2 ã€ã®ãŠã£ã³ããŠãå«ãã§ããŸããã¿ã¹ã¯ ãã¥ãŒã¢ãšæ°ããã¿ã¹ã¯ã§ãã ã¿ã¹ã¯ãã¥ãŒã¢ ã·ã¹ãã ãŸãã¯éžæããã³ã³ãããŒã©ããã£ãã«ãã¢ã¬ã€ããã© ã€ãã®ãçŸåšã®ã¿ã¹ã¯ãšã¹ã±ãžã¥ãŒã«æžã¿ã®ã¿ã¹ã¯ã®è©³çްã衚瀺 ãããŸãã ã¿ã¹ã¯ã®äœæã¯ã¢ã¬ã€ãŸãã¯ãã©ã€ãã«ã€ããŠã®ã¿å¯èœã§ãã ãã£ãã«ãã³ã³ãããŒã©ãã·ã¹ãã ã«ã€ã㊠ã¿ã¹ã¯ ãéžæãã ãšãé¢é£ãããã¹ãŠã®ã¿ã¹ã¯ã衚瀺ãããŸãã Adaptec Storage Manager ãã€ã³ã¹ããŒã«ãããšãã·ã¹ãã ã®ã ã¹ãŠã®ããã ã¹ãã¢ã®äžè²«æ§ãã§ãã¯ãæ¯é±ããã¯ã°ã©ãŠã³ãã§ å®è¡ãããã¹ã±ãžã¥ãŒã«æžã¿ã¿ã¹ã¯ãäœæãããŸãããã®ã¿ã¹ã¯ ã¯ãäœãéžæãããŠããªãå Žåã«ãã¿ã¹ã¯ ãã¯ãªãã¯ãããšè¡šç€º ã§ããŸãã æ°ããã¿ã¹ã¯ ã¢ã¬ã€ãŸãã¯ãã©ã€ãã®æ°ããã¿ã¹ã¯ãäœæã§ããŸããäœæãã æ°ããã¿ã¹ã¯ã¯ãããã«å®è¡ããããåŸã§å®è¡ããããã«ã¹ã± ãžã¥ãŒã«ããããšãã§ããŸããå®è¡å¯èœãªã¿ã¹ã¯ã«ã¯ãããªãã¡ ã€ãããªãã¡ã€ãšä¿®åŸ©ãã¯ãªã¢ ããããŸããããããã®ã¿ã¹ã¯ ã¯ã以äžã®ããã«èª¬æãããŸãã â ãã©ã€ã â ããªãã¡ã€ â ãã©ã€ãå šäœã®ãã¹ããå®è¡ããåé¡ããªã ããšã確èªããŸããäžè¯ãããã¯ãæ€åºãããŠã修埩ã¯è¡ ããŸããã â ããªãã¡ã€ãšä¿®åŸ© â ãã©ã€ãå šäœã®ãã¹ããå®è¡ããåé¡ ããªãããšã確èªããŸããæ€åºãããäžè¯ãããã¯ã修埩 ããŸãã â ã¯ãªã¢ â ãã©ã€ãäžã®ãã¹ãŠã®ããŒã¿ãæ¶å»ããŸãããã© ã€ãã«æ ŒçŽãããŠããããŒã¿ã¯ãããã埩æ§ã§ããŸããã ãŸãããã©ã€ãã®ãã¹ãŠãŸãã¯äžéšãã¢ã¬ã€ã§äœ¿çšãã㊠ããå Žåã¯ãã¢ã¬ã€ã®ããŒã¿ã®å®å šæ§ãæãªãããŸãã 5-26 Adaptec Storage Managerâ Browser Edition ã®äœ¿çš â ã¢ã¬ã€ â ããªãã¡ã€ â ã¢ã¬ã€å šäœã®ãã¹ããå®è¡ããããŒã¿ã«äžè²« æ§ãããããšã確èªããŸããäžæŽåãæ€åºãããŠã修埩㯠è¡ããŸããã â ããªãã¡ã€ãšä¿®åŸ© â ã¢ã¬ã€å šäœã®ãã¹ããå®è¡ããããŒã¿ ã«äžè²«æ§ãããããšã確èªããŸããäžæŽåãæ€åºãããå Ž åã¯ä¿®åŸ©ããŸãã â ã¯ãªã¢ â ã¢ã¬ã€äžã®ãã¹ãŠã®ããŒã¿ãæ¶å»ããŸããã¢ã¬ã€ ã«æ ŒçŽãããŠããããŒã¿ã¯ãããã埩æ§ã§ããŸããã ã¿ã¹ã¯ãäœæããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 ã¿ã¹ã¯ãå®è¡ããã¢ã¬ã€ãŸãã¯ãã©ã€ããéžæããŸãã 2 ã¿ã¹ã¯ ãã¯ãªãã¯ããŸãã 3 æ°ããã¿ã¹ã¯ ãéžæããŸãã 4 ããããããŠã³ ãªã¹ãããã¿ã¹ã¯ã®ã¿ã€ããéžæããŸãã 5 ã¿ã¹ã¯ã®åªå 床ãéžæããŸããåæå€ã¯ é« ã§ãã 6 ã¿ã¹ã¯ãããã«éå§ããå Žåã¯ãOK ãã¯ãªãã¯ããŸããåŸã§ å®è¡ããããã«ã¿ã¹ã¯ãã¹ã±ãžã¥ãŒã«ããå Žåã¯ãã¹ã±ãžã¥ãŒ ã« ãéžæããŸãã ã¹ã±ãžã¥ãŒã« ãéžæãããšã远å ã®ãªãã·ã§ã³ã衚瀺ããã ã¿ã¹ã¯ãéå§ããææ¥ãšæå»ãããã³æéã®åœ¢åŒã衚瀺ãã㟠ããæå»ã𿿥ãéžæããããOK ãã¯ãªãã¯ããŸãã 5-27 A BIOS ãŠãŒãã£ãªã㣠ãã®ç« ã®æŠèŠ ARC ãšã¯äœã A-1 ACU ã®äœ¿çš A-2 SATASelect ã®äœ¿çš A-7 CCU ã®äœ¿çš A-7 SATA Configuration Utility ã®äœ¿çš A-9 Disk Utilities ã®äœ¿çš A-10 ARC ãšã¯äœã ARC (Adaptec RAID Configuration Utility) ã¯çµã¿èŸŒã¿ BIOS ãŠãŒ ãã£ãªãã£ã§ããã以äžãå«ãŸããŠããŸãã â ACU (Array Configuration Utility)â ã¢ã¬ã€ãäœæãæ§æã管 çããã â SATASelect UtilityâSATA (Serial ATA) ããã€ã¹ãšã³ã³ãã㌠ã©ã倿Žããã â CCU (Controller Congifuration Utility)â ã³ã³ãããŒã©ã® BIOS ã®èµ·åã衚瀺ãªãã·ã§ã³ã倿Žããã â SATA Configuration UtilityâSATA ãã£ãã« ã€ã³ã¿ãŒãã§ã€ ã¹ã®å®çŸ©ãš SATA ããã€ã¹èšå®ã®ãªãã·ã§ã³ã倿Žããã â Disk Utilityâ ãã£ã¹ã¯ã®ãã©ãŒããããšç¢ºèªãããã A-1 BIOS ãŠãŒãã£ãªã㣠ARC ãå®è¡ããã«ã¯ãã·ã¹ãã ã®èµ·åããã»ã¹äžã«ä»¥äžã®ã¡ã ã»ãŒãžã衚瀺ãããããCtrl+A ãæŒããŸãã Press <Ctrl><A> for Adaptec RAID Configuration Utility ã䜿ãã®ã³ã³ãã¥ãŒã¿ã«ã2 å° ä»¥äžã® Adaptec 1210SA ã³ã³ã ããŒã©ãããå Žåãã³ã³ãããŒã©ã®äžèЧã衚瀺ãããŸããç¢å° ããŒã䜿çšããŠèšå®ããã³ã³ãããŒã©ãéžæããEnter ãæŒã㟠ãã ARC ã®ã¡ãã¥ãŒã衚瀺ãããŸãããã®ã¡ãã¥ãŒã®ãªãã·ã§ã³ã¯ä»¥ äžã®ãšããã§ãã â Array Configuration Utility (ACU) â SATASelect utility â Disk Utilities ARC ã®ã¡ãã¥ãŒãããªãã·ã§ã³ããã€ã©ã€ãããã«ã¯ãç¢å°ã㌠ã䜿çšããŠãã®ãªãã·ã§ã³ã«ã«ãŒãœã«ãç§»åããEnter ãæŒã㟠ããåã®ã¡ãã¥ãŒã«æ»ãã«ã¯ãEsc ãæŒããŸãã ACU ã®äœ¿çš Array Configuration Utility (ACU) ã䜿çšãããšãã³ã³ãããŒã©ã® BIOS ããã¢ã¬ã€ã®äœæã管çãåé€ãè¡ãããã©ã€ããåæåã ãããšãã§ããŸãã ã¢ã¬ã€ã®ç®¡ç Manage Arrays ãªãã·ã§ã³ã䜿çšããŠãã¢ã¬ã€ã®ããããã£ãã ã³ã¡ã³ããŒã®è¡šç€ºããŸãã¯ã¢ã¬ã€ã®åé€ãè¡ããŸãã以äžã®é ã§ ã¯ããããã®æé ã«ã€ããŠè©³ãã説æããŸãã ã¢ã¬ã€ã®ããããã£ã®è¡šç€º æ¢åã®ã¢ã¬ã€ã®ããããã£ã衚瀺ããã«ã¯ã以äžã®æé ã«åŸã㟠ãã 1 BIOS ã®ã¡ãã»ãŒãžã衚瀺ãããããCtrl+A ãæŒããŸãã 2 ARC ã¡ãã¥ãŒãã Array Configuration Utility (ACU) ãéžæ ããŸãã 3 ACU ã¡ãã¥ãŒãã Manage Arrays ãéžæããŸãã A-2 BIOS ãŠãŒãã£ãªã㣠4 List of Arrays ãã€ã¢ãã° ããã¯ã¹ã§ã衚瀺ãããã¢ã¬ã€ãéž æã㊠Enter ãæŒããŸãã Array Properties ãã€ã¢ãã° ããã¯ã¹ãéããã¢ã¬ã€ã®è©³çްæ å ±ã衚瀺ãããŸããã¢ã¬ã€ã«é¢é£ä»ããããŠããç©çãã£ã¹ã¯ ãããã«è¡šç€ºãããŸãã 5 çŽåã®ã¡ãã¥ãŒã«æ»ãã«ã¯ãEsc ããŒãæŒããŸãã ã¢ã¬ã€ã®åé€ ! ãæ³šæ : ã¢ã¬ã€ãåé€ããåã«ããã®ã¢ã¬ã€äžã®ããŒã¿ã ããã¯ã¢ããããŠãã ãããããããªããã°ãã¢ã¬ã€äžã®å š ãŠã®ããŒã¿ã倱ãããŸããåé€ããã¢ã¬ã€ã埩å ããããšã¯ ã§ããŸããã æ¢åã®ã¢ã¬ã€ãåé€ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããARC ãŠãŒãã£ãªãã£ã« ã¢ã¯ã»ã¹ããããã®ããã³ãããçŸããããCtrl+A ãæŒã㊠äžããã 2 ARC ã¡ãã¥ãŒãã Array Configuration Utility (ACU) ãéžæ ããŸãã 3 ACU ã¡ãã¥ãŒãã Manage Arrays ãéžæããŸãã 4 åé€ããã¢ã¬ã€ãéžæã㊠Delete ãæŒããŸãã 5 Array Properties ãã€ã¢ãã° ããã¯ã¹ã§ãDelete ãéžæã㊠Enter ãæŒããŸãã以äžã®ã¡ãã»ãŒãžã衚瀺ãããŸãã Warning!!Do you want to delete the array?(Yes/No): 6 ã¢ã¬ã€ãåé€ããå Žå㯠YesãçŽåã®ã¡ãã¥ãŒã«æ»ãã«ã¯ No ãéžæããŸãã 7 çŽåã®ã¡ãã¥ãŒã«æ»ãã«ã¯ãEsc ããŒãæŒããŸãã ã¢ã¬ã€ã®äœæ ã¢ã¬ã€ãäœæããåã«ãã¢ã¬ã€ã«äœ¿çšããåãã£ã¹ã¯ãã·ã¹ãã ã«æ¥ç¶ããã³åãä»ããããŠããããšã確èªããŠãã ãããäœ¿çš å¯èœãªã¹ããŒã¹ããªããã£ã¹ã¯ããŸãã¯åæåãããŠããªãã£ã¹ ã¯ã¯ã°ã¬ãŒã§è¡šç€ºãããŠãã䜿çšã§ããŸãããA-6 ããŒãžã® ããã£ã¹ã¯ ãã©ã€ãã®åæåããåç §ããŠãã ããã A-3 BIOS ãŠãŒãã£ãªã㣠ã¢ã¬ã€ãäœæããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããARC ãŠãŒãã£ãªãã£ã« ã¢ã¯ã»ã¹ããããã®ããã³ãããçŸããããCtrl+A ãæŒã㊠äžããã 2 ARC ã¡ãã¥ãŒãã Array Configuration Utility (ACU) ãéžæ ããŸãã(ACU) 3 ACU ã¡ãã¥ãŒãã Create Array ãéžæããŸãã 4 æ°ããã¢ã¬ã€ã«äœ¿çšãããã£ã¹ã¯ãéžæããInsert ãæŒã㟠ãããã£ã¹ã¯ã®éžæãè§£é€ããã«ã¯ããã£ã¹ã¯ããã€ã©ã€ã衚 瀺ããŠãã Delete ãæŒããŸãã 5 æ°ããã¢ã¬ã€ã«äœ¿çšãããã£ã¹ã¯ãäž¡æ¹éžæã㊠Enter ãæŒã ãŸããArray Properties ã¡ãã¥ãŒã衚瀺ãããŸãã ã¢ã¬ã€ã®ããããã£ã®æå® ã¡ã¢ : ã¢ã¬ã€ãäœæãããããããã£ãèšå®ãããããã¢ã¬ ã€ã®ããããã£ã¯ ACU ã§å€æŽããããšã¯ã§ããŸãããã㮠代ãããAdaptec Storage Manager - Browser Edition ã䜿㣠ãŠãã ããã( 詳现ã«ã€ããŠã¯ã第 5 ç« ãåç §ãã ããã) æ°ããã¢ã¬ã€ã«ããããã£ãæå®ããã«ã¯ã以äžã®æé ã«åŸã㟠ãã 1 Array Properties ã¡ãã¥ãŒã§ãã¢ã¬ã€ã®ã¿ã€ããéžæã㊠Enter ãæŒããŸãã䜿çšå¯èœãªã¢ã¬ã€ã¿ã€ããRAID 0 ãš RAID 1 ã ãã衚瀺ãããŸãããããã®ãããã®ã¿ã€ããã2 ã€ã®ã ã©ã€ããå¿ èŠã§ãã( ãããã®ã¢ã¬ã€ ã¿ã€ãã«ã€ããŠã®èª¬æ ã¯ãä»é² B ãåç §ããŠãã ããã) 2 ã¢ã¬ã€ã®ã©ãã«ãå ¥åã㊠( ãªãã·ã§ã³ ) Enter ãæŒããŸãã 3 RAID 0 ã®å Žåã¯ã䜿çšããã¹ãã©ã€ã ãµã€ãºãéžæããŸãã å¯èœãªã¹ãã©ã€ã ãµã€ãºã¯ 16ã32ãããã³ 64KB ( åæå€ ) ã§ ãã ã¡ã¢ : ã¢ããããã¯ã¯ãåæå€ã®èšå®ã¯å€æŽããªã ããš ããå§ãããŸãã A-4 BIOS ãŠãŒãã£ãªã㣠4 Create RAID via ã«ãããRAID 0 ããã³ RAID 1 ã«å¯ŸããŠç°ãª ãäœææ¹æ³ãéžæããããšãã§ããŸããæ¬¡ã®è¡šã«å Create via ãš RAID ã¬ãã«ã®æé©çšéã®äŸã瀺ããŸãã RAID ã¬ãã« Create via æé©çšé RAID 0 No Init RAID 0 ãæ°ãããã©ã€ãã«äœæããå Žå RAID 0 Migrate1 RAID 0 ããæ°ãããã©ã€ããšä¿åãã ããŒã¿ãæ ŒçŽããããã©ã€ãããäœæãã å Žå RAID 1 Build1 äžè¬çã« RAID 1 ãäœæããå Žåãç¹ã«ä¿ åããããŒã¿ãçæ¹ã®ãã©ã€ãã«ããå Žå RAID 1 Clear RAID 1 ãæ°ãããã©ã€ãã«äœæããå Žåã ãŸãã¯ãã©ã€ãäœæåŸã«ã¢ã¬ã€ã«ããŒã¿ã ãªãããšã確å®ã«ãããå Žå RAID 1 Quick Init RAID 1 äœæã®æçæ¹æ³ãæ°ãããã©ã€ãã 䜿çšããå Žåã«æé©ã 1 RAID 0 ã« MigrateããŸã㯠RAID 1 ã« Build ãéžæãããšããœãŒã¹ ã ã©ã€ããéžæããããæ±ããããŸãããœãŒã¹ãã©ã€ãã®å 容ã¯ä¿å ãããŸãããããæ°ãããã©ã€ãäžã®ããŒã¿ã¯å€±ãããŸãã ã¡ã¢ : â æ°ãããã©ã€ããã¢ã¬ã€ã«è¿œå ããåã«ãæ°ãããã©ã€ã äžã®ããŒã¿ã®ããã¯ã¢ãããåã£ãŠãã ãããããããªã ãã°ãå šãŠã®ããŒã¿ã倱ãããŸãã â ACU ã§ãRAID 1 ã® Build ãŸã㯠Clear ããã»ã¹ãäžæ¢ãã ãšãAdaptec Storage Manager -Browser Edition ã«ããåèµ· åã®ã¿ãå¯èœã§ãã( 詳现ã«ã€ããŠã¯ã第 5 ç« ããåç §ã ã ããã) â Quick Init ãªãã·ã§ã³ã§äœæãã RAID 1 ã¯ãåŸã§äžè²«æ§ ãã§ãã¯ãå®è¡ãããšãããŒã¿ã®äžäžèŽãèŠã€ããå Žåã ãããŸããããã¯æ£åžžãªåäœã§ãããå¿é ããå¿ èŠã¯ãã ãŸããã â ACU ã¯ãRAID 1 ã«ç°ãªããµã€ãºã®ãã©ã€ãã䜿ãããšã èš±å¯ããŸãã2 å°ç®ã®ãã©ã€ãã«å°ããªå®¹éã®ãã©ã€ãã éžã¶ãšãããŒã¿ãã¹ã®ãªã¹ã¯ããããšããèŠåãåããŸãã A-5 BIOS ãŠãŒãã£ãªã㣠! ãæ³šæ : Migrate ãªãã·ã§ã³ã䜿çšãã RAID 0 ã®äœæã¯ äžæããªãã§ãã ãããäžæããå Žåã«ã¯ãåèµ·åãã æ¹æ³ããªãããœãŒã¹ãã©ã€ãäžã®ããŒã¿ããªã«ããŒãã æ¹æ³ããªããªããŸãã 5 å®äºããã Done ãæŒããŸãã ãã£ã¹ã¯ ãã©ã€ãã®åæå æ°ããã¢ã¬ã€ãäœæããããã®ãã£ã¹ã¯éžæãªã¹ãã«åãä»ãæž ã¿ã®ãã£ã¹ã¯ã衚瀺ãããªãå Žåããããã¯ã°ã¬ãŒè¡šç€ºãããŠã ãå Žåã¯ãã¢ã¬ã€ã®äžéšãšããŠäœ¿çšããåã«ãã®ãã£ã¹ã¯ãåæ åããå¿ èŠããããŸããã³ã³ãããŒã©ã«æ¥ç¶ããããã©ã€ãã¯ã ã¢ã¬ã€ã§äœ¿çšããåã«åæåããå¿ èŠããããŸãã ! ãæ³šæ : ãã£ã¹ã¯ãåæåãããšããã£ã¹ã¯äžã®ããŒã㣠ã·ã§ã³ ããŒãã«ãäžæžãããããã®ãã£ã¹ã¯äžã®ãã¹ãŠã® ããŒã¿ã«ã¢ã¯ã»ã¹ã§ããªããªããŸãããŸãããã©ã€ããã¢ã¬ ã€ã§äœ¿çšãããŠããå Žåã¯ããã®ã¢ã¬ã€ãå床䜿çšã§ããªã ãªãããšããããŸããèµ·åã¢ã¬ã€ã®äžéšã§ãããã£ã¹ã¯ã¯ å æåããªã ãã ãããã©ã®ãã£ã¹ã¯ãã©ã®ã¢ã¬ã€ã«é¢é£ã㊠ãããã倿ããã«ã¯ãA-2 ããŒãžã®ãã¢ã¬ã€ã®ãããã㣠ã®è¡šç€ºããåç §ããŠãã ããã ãã©ã€ããåæåããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããARC ãŠãŒãã£ãªãã£ã« ã¢ã¯ã»ã¹ããããã®ããã³ãããçŸããããCtrl+A ãæŒã㊠äžããã 2 ARC ã¡ãã¥ãŒãã Array Configuration Utility (ACU) ãéžæ ããŸãã 3 Initialize Drives ãéžæããŸãã 4 äžåã / äžåãã®ç¢å°ããŒã䜿çšããŠãåæåãããã£ã¹ã¯ã ãã€ã©ã€ã衚瀺ããInsert ãæŒããŸãã 5 æé 4 ãç¹°ãè¿ããŠãåæåãããã¹ãŠã®ãã©ã€ããéžæã㟠ãã 6 Enter ããŒãæŒããŸãã A-6 BIOS ãŠãŒãã£ãªã㣠7 èŠåã¡ãã»ãŒãžãèªã¿ãåæåãããã£ã¹ã¯ ãã©ã€ããæ£ã ãéžæãããŠããããšã確èªããŸããç¶è¡ããã«ã¯ Y ãšå ¥åã ãŸãã SATASelect ã®äœ¿çš SATASelect ãŠãŒãã£ã¬ã㣠ã䜿çšãããšãã·ã¹ãã ã®ã·ã£ãŒã·ã éãããã«ãŒããè§Šããã«ãããã€ã¹ãã³ã³ãããŒã©ã®èšå®ãå€ æŽããããšãã§ããŸãã SATASelect ã®èµ·åãšçµäº SATASelect ãèµ·åããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããARC ãŠãŒãã£ãªãã£ã« ã¢ã¯ã»ã¹ããããã®ããã³ãããçŸããããCtrl+A ãæŒã㊠äžããã 2 è€æ°ã®ã³ã³ãããŒã©ãåãä»ããããŠããå Žåã¯ãèšå®ãè¡ã ã³ã³ãããŒã©ãéžæã㊠Enter ãæŒããŸãã 3 ARC ã¡ãã¥ãŒãã SATASelect Utility ãéžæããŸãã Controller Configuration ã¡ãã¥ãŒãš SATA Configuration ã¡ ãã¥ãŒã®ãªãã·ã§ã³ã衚瀺ãããŸãã SATASelect ãçµäºããã«ã¯ãçµäºãããšããã¡ãã»ãŒãžã衚瀺ã ãããŸã§ Esc ããŒãæŒããŸãã( èšå®ã倿Žããå Žåã¯ãçµäºãã åã«å€æŽã®ä¿åãæ±ããã¡ãã»ãŒãžã衚瀺ãããŸã )ãYes ãéžæ ãããšããŠãŒãã£ãªãã£ãçµäºããã·ã¹ãã ãåèµ·åããŸããå€ æŽå 容ã¯ãã¹ãŠãã·ã¹ãã ã®èµ·ååŸã«æå¹ã«ãªããŸãã SATASelect ã¡ãã¥ãŒã®äœ¿çš SATASelect ã¡ãã¥ãŒ ãªãã·ã§ã³ãéžæããã«ã¯ãäžåã / äžå ãã®ç¢å°ããŒã䜿çšããŠãã®ãªãã·ã§ã³ã«ã«ãŒãœã«ãç§»åãã Enter ãæŒããŸãã CCU ã®äœ¿çš Controller Configuration Utility ã«ã¢ã¯ã»ã¹ããã«ã¯ã以äžã®æé ã«åŸããŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããARC ãŠãŒãã£ãªãã£ã« ã¢ã¯ã»ã¹ããããã®ããã³ãããçŸããããCtrl+A ãæŒã㊠äžããã A-7 BIOS ãŠãŒãã£ãªã㣠2 è€æ°ã®ã³ã³ãããŒã©ãåãä»ããããŠããå Žåã¯ãèšå®ãè¡ã ã³ã³ãããŒã©ãéžæã㊠Enter ãæŒããŸãã 3 ARC ã¡ãã¥ãŒãã SATASelect Utility ãéžæããŸãã Controller Configuration ã¡ãã¥ãŒãš SATA Configuration ã¡ ãã¥ãŒã®ãªãã·ã§ã³ã衚瀺ãããŸãã 4 Controller Configuration ãéžæããŸãã 以äžã®ã³ã³ãããŒã© ã€ã³ã¿ãŒãã§ã€ã¹ã®ãªãã·ã§ã³ã¯å€æŽã§ ããŸãã â Runtime BIOSâ ã³ã³ãããŒã©ã®ã©ã³ã¿ã€ã BIOS ãæå¹ãŸ ãã¯ç¡å¹ã«ããŸããã³ã³ãããŒã©ããèµ·åããå Žåã¯ã BIOS ãæå¹ã«ããå¿ èŠããããŸãã Runtime BIOS ãæå¹ã§ãArray-based BBS Support ãªã ã·ã§ã³ãç¡å¹ã®å Žåãã³ã³ãããŒã©ã® BIOS ãæå¹ã«ãªãã ã³ã³ãããŒã©ã«æ¥ç¶ãããæåã®ã¢ã¬ã€ ( ãŸãã¯ãã©ã€ã ) ãèµ·åããŒããã£ã¹ã¯ ãã©ã€ããšããŠæ±ãããŸãã åæå€ã¯ Enabled ã§ãã â Array-based BBS Support â Runtime BIOS ããã³ãã®ãª ãã·ã§ã³ãæå¹ãªå Žåãã·ã¹ãã ã«ããåã³ã³ãããŒã©äž ã®ãã¹ãŠã®ããã€ã¹ ( ã¢ã¬ã€ãŸãã¯ãã©ã€ã ) ã BBS ãã ã€ã¹ãšããŠæ±ãããŸãã BBS ãæå¹ãªã·ã¹ãã ã§ãArray based BBS support ãæå¹ ãªå ŽåãHard drive boot order menu ã«ã¯ãåãä»ãã RAID ã³ã³ãããŒã©ã«æ¥ç¶ãããå šã¢ã¬ã€ ( ãŸãã¯ãã©ã€ã ) ã®ãšã³ããªãå ¥ããããŸãã åæå€ã¯ Enabled ã§ãã â Physical Drives Display during POSTâ åæå€ã¯ Disabled ã§ãã A-8 BIOS ãŠãŒãã£ãªã㣠SATA Configuration Utility ã®äœ¿çš SATA Configuration Utility ã䜿çšãããšãSATA ãã£ãã« ã€ã³ ã¿ãŒãã§ã€ã¹ã®ãªãã·ã§ã³ãš SATA ããã€ã¹èšå®ã®ãªãã·ã§ã³ã 倿Žã§ããŸãã SATA Configuration Utility ã«ã¢ã¯ã»ã¹ããã«ã¯ã以äžã®æé ã«åŸ ããŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããARC ãŠãŒãã£ãªãã£ã« ã¢ã¯ã»ã¹ããããã®ããã³ãããçŸããããCtrl+A ãæŒã㊠äžããã 2 è€æ°ã®ã³ã³ãããŒã©ãåãä»ããããŠããå Žåã¯ãèšå®ãè¡ã ã³ã³ãããŒã©ãéžæã㊠Enter ãæŒããŸãã 3 ARC ã¡ãã¥ãŒãã SATAISelect ãéžæããŸãã Controller Configuration ã¡ãã¥ãŒãš SATA Configuration ã¡ ãã¥ãŒã®ãªãã·ã§ã³ã衚瀺ãããŸãã 4 SATA Configuration ãéžæããŸãã 5 Select SATA Channel ã¡ãã¥ãŒã衚瀺ãããŸãããã®ã¡ãã¥ãŒ ããé©åãªãã£ãã«ãéžæããŸãã 以äžã® SATA ããã€ã¹èšå®ã®ãªãã·ã§ã³ã倿Žã§ããŸãã â Write Cache â ãã©ã€ãã®ã©ã€ã ãã£ãã·ã¥ãæå¹ãŸã㯠ç¡å¹ã«ããŸããã©ã€ã ãã£ãã·ã¥ãæå¹ã«ãããšãæå€§é ã®ããã©ãŒãã³ã¹ãåŸãããŸãã â DMAâ ãã©ã€ãã® DMA (Direct Memory Access) ã¢ãŒãã æå¹ãŸãã¯ç¡å¹ã«ããŸãããã®ã¢ãŒããæå¹ã«ãããšãæ 倧éã®ããã©ãŒãã³ã¹ãåŸãããŸãã â SMARTâ ãã£ã¹ã¯ ãã©ã€ãã®éå®³äºæž¬æ©èœãæå¹ãŸã㯠ç¡å¹ã«ããŸãããã®ãªãã·ã§ã³ãæå¹ãªå ŽåãPOST äžã« ç©çãã©ã€ã衚瀺ãšãšãã«ããã©ã€ãã® SMART ã¹ããŒã¿ ã¹ ( æ£åžžãŸãã¯æ é ) ã衚瀺ãããŸãããã©ã€ãã SMART ããµããŒãããŠããªãå Žåã¯ãSMART ã¹ããŒã¿ã¹ã¯è¡šç€º ãããŸããã A-9 BIOS ãŠãŒãã£ãªã㣠â Allow Read Aheadâ â ãã©ã€ãã® å èªã¿ãã£ãã·ã¥ ã¢ã« ãŽãªãºã ãæå¹ãŸãã¯ç¡å¹ã«ããŸããã»ãšãã©ã®ç°å¢ã«ã ããŠããã®ãªãã·ã§ã³ãæå¹ã«ãããšãæå€§éã®ããã©ãŒ ãã³ã¹ãåŸãããŸãã ãã¹ãŠã®ãªãã·ã§ã³ã®åæå€ã®èšå®ã¯ãEnabled ã§ãã Disk Utilities ã®äœ¿çš BIOS ããŒã¹ã® Disk Utilities ã䜿çšãããšãSATA ããŒããã£ã¹ ã¯ã®ããŒã¬ãã« ãã©ãŒãããããã£ã¹ã¯ ã¡ãã£ã¢ã®æ€èšŒãè¡ãã ãšãã§ããŸãã ãã£ã¹ã¯ ãŠãŒãã£ãªãã£ã«ã¢ã¯ã»ã¹ããã«ã¯ã以äžã®æé ã«åŸã ãŸãã 1 ã䜿ãã®ã³ã³ãã¥ãŒã¿ã®é»æºãå ¥ããARC ãŠãŒãã£ãªãã£ã« ã¢ã¯ã»ã¹ããããã®ããã³ãããçŸããããCtrl+A ãæŒã㊠äžããã 2 è€æ°ã®ã³ã³ãããŒã©ãåãä»ããããŠããå Žåã¯ãèšå®ãè¡ã ã³ã³ãããŒã©ãéžæã㊠Enter ãæŒããŸãã 3 ARC ã¡ãã¥ãŒãã Disk Utilities ãéžæããŸãã 4 察象ã®ãã£ã¹ã¯ãéžæããEnter ãæŒããŸãã 以äžã®ãªãã·ã§ã³ã¯äœ¿çšã§ããŸããã â Format Diskâ ãã©ã€ãå šäœã«ãŒããæžã蟌ãããšã§ãã㌠ããã£ã¹ã¯ãã©ã€ãã®ãã©ãŒããããã·ãã¥ã¬ãŒãããŸãã SATA ãã£ã¹ã¯ ãã©ã€ãã¯å·¥å Žåºè·æã«ããããããã©ãŒ ããããããŠãããããå床ãã©ãŒãããããå¿ èŠã¯ãã ãŸããã ! â ãæ³šæ : ãã©ã€ãäžã®ãã¹ãŠã®ããŒã¿ãæ¶å»ããŸãã ãã®æäœãå®è¡ããåã«ãå¿ ãããŒã¿ãããã¯ã¢ãã ããŠãããŠãã ããã Verify Disk Mediaâ ãã£ã¹ã¯ ãã©ã€ãã®ã¡ãã£ã¢ãã¹ ãã£ã³ããŠãšã©ãŒããã§ãã¯ããŸããèŠã€ãã£ããšã©ãŒã¯ å šãŠä¿®æ£ãããŸãã A-10 B ãµããŒããããŠãã RAID ã¿ã€ã Redundant Array of Independent (Inexpensive) Disks ã®é æåèªã RAID ã®ç®çã¯ããã£ã¹ã¯ãã©ã€ãã®çµã¿åããã§ãRAID ãªãã§ ã®åãã¹ãã¬ãŒãžå®¹éã§åŸããã以äžã®ãé«ããã©ãŒãã³ã¹ãã ã³ä¿¡é Œæ§ãå®çŸããããšã§ãã RAID ãæ§ç¯ããæãåäžã®å®¹éãšããã©ãŒãã³ã¹ã®ãã©ã€ãã éžãã§ãã ãããããããªããšãRAID ã¯ãå°ãªãé ãã»ãã«å®¹ éãããã©ãŒãã³ã¹ãå¶éããåŸåã«ãããŸãã Adaptec 1210 SA ã¯ã2 ã€ã®ãã©ã€ããŸã§ãµããŒãããŸãã®ã§ã RAID 0 ãš RAID 1 ã¢ã¬ã€ã®ã¿ããµããŒããããŸããã¢ã¬ã€ã®ã¿ã€ ãã¯ã以äžã§èª¬æããŸãã RAID ã®æ©èœã«å ããAdaptec 1210SA ã¯ãã¢ã¬ã€ã®äžéšã§ã¯ ãªã åäžã®ãã©ã€ãã§æ§æããããã·ã³ãã« ããªã¥ãŒã ããµããŒãã ãŸãããã®ãããªãã©ã€ãã¯èªåçã«ã·ã³ãã«ããªã¥ãŒã ãšã㊠èšå®ãããŸããã³ã³ãããŒã©ã¯ã2 ã€ã® ã·ã³ãã«ããªã¥ãŒã ããµ ããŒãããŸãã B-1 ãµããŒããããŠãã RAID ã¿ã€ã RAID 0 RAID 0 ã¯ãããŒã¿ãè€æ°ã®ãã£ã¹ã¯ ãã©ã€ãã«åæ£ä¿ç®¡ ( ã¹ãã© ã€ãã³ã° ) ããææ³ã§ãããã®ã¹ãã©ã€ãã³ã° ã¹ããŒã ã¯ãã㌠ã¿ãä¿è·ããåé·æ§ã¯ãããŸãããããããè€æ°ã®ãã©ã€ãã§è² è·ãåçã«åæ£ããã®ã§ãRAID 0 㯠RAID ã®ã¿ã€ãã®äžã§ãæã èªã¿æžãã®ããã©ãŒãã³ã¹ãåªããŠããŸãã RAID-0 RAID 1 Data 0 Data 1 Data 0 Data 0 Data 2 Data 3 Data 1 Data 1 Data 4 Data 5 Data 2 Data 2 Data 6 Data 7 Data 3 Data 3 RAID 1 RAID 1 ã¢ã¬ã€ã¯å šãŠã®ããŒã¿ã 1 å°ã®ãã©ã€ããã 2 å°ç®ã®ãã© ã€ããžãã³ããŒããã©ãªã³ã°ããŠäœæããŸãããã®ãã©ãŒãªã³ã° ã¯ãåé·æ§ ãæäŸãã1 å°ã®ãã©ã€ããæ éããŠãããŒã¿ã¯å€±ã ããŸãããåé·æ§ã¯ããŸã䜿çšå¯èœãªå®¹éãå šå®¹éã®ååã«ãªã ããšãæå³ããŸãã RAID 1 ã¯ãã·ã³ãã« ããªã¥ãŒã ã«å¯Ÿããæžã蟌ã¿ããã©ãŒãã³ ã¹ã®å©ç¹ã¯ãããŸãããããããè€æ°ã®ãã©ã€ãã§è² è·ãåçã«å æ£ããã®ã§ãRAID 1 ã¯èªã¿èŸŒã¿ã®ããã©ãŒãã³ã¹ãåäžããŸãã B-2 C 仿§ 黿ºèŠä»¶ ãã«ã 5 V ± 10% ãªããã«ããã³ãã€ãº æå€§ 50 m V p-p 黿µä»æ§ Adaptec 1210SA æå€§ 1 A ç°å¢ä»æ§ åšèŸºæž©åºŠ 0 °C - 50 ° C çžå¯Ÿæ¹¿åºŠ 10% ïœ 90% çµé²ãªã æšé« 3000 ã¡ãŒã¿ãŒãŸã§ ã¡ã¢ : åŒ·å¶ææ°ãæšå¥šããŸãããå¿ é ã§ã¯ãããŸããã C-1 çšèªé A Activity ( ã¢ã¯ãã£ãã㣠) ãTask ( ã¿ã¹ã¯ )ããåç §ããŠãã ããã ACU Array Configuration Utilityãã³ã³ãããŒã©ã® BIOS ãŸã㯠MSDOS ããã¢ã¬ã€ã®äœæãæ§æã管çãè¡ãããã«äœ¿çšããã¢ã㪠ã±ãŒã·ã§ã³ã Array ( ã¢ã¬ã€ ) 1 å°ãŸãã¯è€æ°å°ã®ç©çãã£ã¹ã¯äžã®äœ¿çšå¯èœã¹ããŒã¹ããäœæ ããã1 ã€ãŸãã¯è€æ°ã®ã»ã°ã¡ã³ãã§æ§æããã 1 ã€ã®è«çã㣠ã¹ã¯ãéåžžãã¢ã¬ã€ã¯ããŒã¿ã®åé·æ§ãäžå±€ã® I/O ããã©ãŒãã³ ã¹ãåŸãç®çã§äœ¿çšããŸãããContainer ( ã³ã³ãã )ãããSegment ( ã»ã°ã¡ã³ã )ãã ãvolume ( ããªã¥ãŒã )ãã ãSpanned Volume ( ã¹ãã³ ããªã¥ãŒã )ãããRAID 0ããåç §ããŠãã ããã ã³ã³ãã ãšãåŒã°ããŸãã Array Initialization ( ã¢ã¬ã€ã®åæå ) ãInitialize ( åæå )ããåç §ããŠãã ããã ATA AT Bus Attachmentããã¹ã¯ããã ã³ã³ãã¥ãŒã¿ãããšã³ããªã¬ ãã« ãµãŒããŒã§äžè¬çã«äœ¿çšããã IDE ããŒããã£ã¹ã¯ã®æšæºã ã©ã¬ã« ã€ã³ã¿ãŒãã§ã€ã¹ã ãSerial ATA (SATA)ãã¯ããã©ã¬ã« ATA (PATA ãšåŒã°ããããšããããŸã ) ã®åŸç¶ã§ãã çšèªé -1 çšèªé Available Space/segmemt ( 䜿çšå¯èœã¹ããŒã¹ / ã»ã°ã¡ã³ã ) åæåæžã¿ãã£ã¹ã¯äžã®æªäœ¿çšã¹ããŒã¹ããã®ã¹ããŒã¹ã䜿çšã ãŠè«çãã©ã€ã ( ã¢ã¬ã€ ) ãäœæããããšãã§ããŸããã¢ã¬ã€ã åé€ãããšããã®ã¢ã¬ã€ã䜿çšããŠããã¹ããŒã¹ã¯äœ¿çšå¯èœã¹ ããŒã¹ ããŒã«ã«æ»ãããŸãã B Bad Segment ( äžè¯ã»ã°ã¡ã³ã ) èªèäžèœãªã»ã°ã¡ã³ãã Background Consistency Check ( ããã¯ã°ã©ãŠã³ãã§ã®äžè²«æ§ ãã§ã㯠) ãã¹ãŠã®ã¢ã¬ã€ã䜿çšããŠãããã£ã¹ã¯ã®ãã¹ãŠã®éšåãã³ã³ã ããŒã©ãåžžã«ãã§ãã¯ãããã£ã¹ã¯ã®ãããã¯ããããŒã¿ãè¿ã ãããã©ããã確èªãããªãã·ã§ã³ã ãConsistency Check Command ( äžè²«æ§ãã§ã㯠ã³ãã³ã )ããåç §ããŠãã ããã Bootable Array ( ããŒã¿ãã«ã¢ã¬ã€ ) èµ·åããã€ã¹ãšããŠèšå®ãããŠããã¢ã¬ã€ã Build ( æ§ç¯ ) åé·ã¢ã¬ã€ã®ããã¯ã°ã©ãŠã³ãåæååŠçãåŠçã®å®è¡äžãã㢠ã¬ã€ã«ã¢ã¯ã»ã¹ããããšãã§ããŸããRAID 1 ã§ã¯ããã©ã€ã㪠ãã©ã€ãããã»ã«ã³ã㪠ãã©ã€ããžå 容ãã³ããŒãããŸãã ãClear ( ã¯ãªã¢ )ããåç §ããŠãã ããã Bus ( ãã¹ ) ãChannel ( ãã£ãã« )ããåç §ããŠãã ããã C Cache ( ãã£ãã·ã¥ ) åããã€ã¹ãšã®éã§ãããšããããããŒã¿çšã®äžéèšæ¶é åãšã ãŠã®åœ¹å²ãæãããã³ã³ãããŒã©äžã®é«éã¢ã¯ã»ã¹ ã¡ã¢ãªã Capacity ( 容é ) 䜿çšå¯èœã¹ããŒã¹ã®åèšãã¡ã¬ãã€ãåäœãŸãã¯ã®ã¬ãã€ãåäœ ã§è¡šãããŸãã çšèªé -2 çšèªé Channel ( ãã£ãã« ) ããŒã¿ã®äŒéããã³ã¹ãã¬ãŒãž ããã€ã¹ãšã¹ãã¬ãŒãž ã³ã³ãã㌠ã©éã®æ å ±ã®å¶åŸ¡ã«äœ¿ãããããã ãã¹ ã®ããšãSerial ATA ã㣠ãã«ã®å Žåã¯ãåãã£ãã«ã®å®¹éã¯åäžãã©ã€ãã®å®¹éã§ãã Chunk ( ãã£ã³ã¯ ) ãStripe ( ã¹ãã©ã€ã )ããåç §ããŠãã ããã Clear ( ã¯ãªã¢ ) èé害æ©èœãåããã¢ã¬ã€ã®ãã©ã¢ã°ã©ãŠã³ãåæååŠçãã¢ã¬ ã€ã®ãã¹ãŠã®ãããã¯ã ã¯ãªã¢ åŠçã«ãã£ãŠããŒãã«ããŸãã㯠ãªã¢ã®ã¿ã¹ã¯ãå®äºãããŸã§ã®éãã¢ã¬ã€ã«ã¢ã¯ã»ã¹ããããšã¯ ã§ããŸããã concatenation ( é£çµ ) è€æ°ã®ç©çãã©ã€ããŸãã¯è«çãã©ã€ããé£ç¶ããŠæ¥ç¶ããããšã Consistency Check Command ( äžè²«æ§ãã§ã㯠ã³ãã³ã ) åãããã¯éã«äžè²«æ§ãããããšã確èªããç®çã§ãRAID 1 ã¢ã¬ ã€ã®ãã¹ãŠã®ãããã¯ãèªã¿èŸŒãã³ãã³ããèŠã€ãã£ãäžæŽåã ããã¯ã¯å šãŠä¿®æ£ãããŸãã Container ( ã³ã³ãã ) ãArray ( ã¢ã¬ã€ )ããåç §ããŠãã ããã D Dead Partition ( äžè¯ããŒãã£ã·ã§ã³ ) ãFailed ( æ é )ããåç §ããŠãã ããã Dedicated Hot Spare ( å°çšããã ã¹ã㢠) èé害æ§ãåããã¢ã¬ã€ã«ãããŠãæ éããã³ã³ããŒãã³ããšå·® ãæ¿ããããããã«æç€ºçã«æå®ãããŠããã³ã³ããŒãã³ãã Degraded ( ãã°ã¬ãŒã ) åé·ã¢ã¬ã€ ( äŸãã° RAID 1) ã® 1 ãŸãã¯è€æ°ã®ã¡ã³ããŒãæ éã ããã®ãããŒã¿ã¯å®å šã§ããåé·æ§ã¯æãããªãããç¶æ ã«ãã ãŸããæŽã«æ éãããšãããŒã¿ã®æå€±ã«ç¹ãããŸãã çšèªé -3 çšèªé Dirty data ( ããŒã㣠ããŒã¿ ) ãCache ( ãã£ãã·ã¥ )ããžã®æžã蟌ã¿ã¯è¡ãããŠããŠãããŸã æçµ çãªæžã蟌ã¿å ã«ããã©ãã·ã¥ããããŠããªãããŒã¿ã Disk ( ãã£ã¹ã¯ ) ç©çãã£ã¹ã¯ ãã©ã€ããã©ã³ãã ã¢ã¯ã»ã¹ãšæžãæããå¯èœãª ããŒã¿ ã¹ãã¬ãŒãž ããã€ã¹ãããŒããã£ã¹ã¯ ãšãåŒã°ããŸãã Disk ID ( ãã£ã¹ã¯ ID) ãã£ãã«çªå·ãSATA ID ã§æ§æãããäžæã®ãã£ã¹ã¯ IDãããšã ã°ã( ãã£ãã« :ID:LUN) 1:04:0 ã®ããã«ãªããŸãããChannel ( ãã£ãã« )ããåç §ããŠãã ããã Drive LED ( ãã©ã€ã LED) èªã¿åãåŠçãŸãã¯æžã蟌ã¿åŠçã®æäžã«ç¹ç¯ããããã£ã¹ã¯ 〠ã³ãžã±ãŒã¿ LEDã Event ( ã€ãã³ã ) 倿Žãèµ·ãã£ãããšãã瀺ããã·ã¹ãã ããã®éç¥ãŸãã¯èŠåã Event Log ( ã€ãã³ã ãã° ) ãããŸã§ã®ã³ã³ãããŒã©ã®ã¢ã¯ãã£ããã£ããã³ãšã©ãŒã«é¢ãã æ å ±ãä¿æããç®çã§äœ¿çšãããã¡ã€ã«ã Event Notification ( ã€ãã³ãéç¥ ) ã€ãã³ãã転éããããã»ã¹ F Failed ( æ é ) åé·æ§ãæããªãã¢ã¬ã€ã§ãåäžãã©ã€ãã®æ éãèµ·ãã£ãå Žåã ãŸãã¯åé·ã¢ã¬ã€ã§è€æ°ãã©ã€ãã®æ éãèµ·ãã£ãå Žåã®ããã ãã®ã¢ã¬ã€ã®ç¶æ ãæ éããã¢ã¬ã€ã¯ãã¢ã¯ã»ã¹äžèœã«ãªãã ããŒã¿ãæå€±ããŸãã Failed Segment ( æ éã»ã°ã¡ã³ã ) è«ççã«äžè¯ã§ããããã«å¿ èŠããªããªã£ãããããã¯ç©ççã« æå·ãããšããçç±ã§ãã¢ã¬ã€ã§äœ¿çšã§ããªããªã£ã ãSegment ( ã»ã°ã¡ã³ã )ãã çšèªé -4 çšèªé Fault-tolerant Arrays ( èé害æ©èœãåããã¢ã¬ã€ ) ãã£ã¹ã¯ ãã©ã€ãã®æ éã«å¯Ÿããèæ§ãåãããåžžã«éçšãç¶ç¶ ããããšãã§ããã¢ã¬ã€ãèé害æ©èœããŸãã¯åé·æ§ãåãã㢠ã¬ã€ã«ã¯ãRAID 1 ã¢ã¬ã€ããããŸãããåé·æ§ããåç §ããŠãã ããã Foreign Disk ( å€éšãã£ã¹ã¯ ) å¥ã® Adaptec RAID ã³ã³ãããŒã©äžã§æ¢ã«åæåãããŠããã㣠ã¹ã¯ããã£ã¹ã¯äžã® RAID ã·ã°ããã£ã䜿çšããããšã«ããã RAID ã³ã³ãããŒã©ã¯ããã®ãã£ã¹ã¯ãçŸåšæ¥ç¶ãããŠããã³ã³ ãããŒã©äžã§åæåããããã®ãã©ãããèå¥ããããšãã§ã㟠ãã H Hard Disk ( ããŒããã£ã¹ã¯ ) äžæ®çºã¡ã¢ãªãéãªã ãŒããã«ã¿ã€ããç£æ°ã®èšæ¶ã¡ãã£ã¢ã®åº æ¬ãŠããããDisk ( ãã£ã¹ã¯ )ããåç §ããŠãã ããã Hot Swap ( ããã ã¹ã¯ãã ) 黿ºãèœãšããã«ããã€ã·ã¹ãã ã皌åããŠããç¶æ ã§ãã·ã¹ã ã ããã³ã³ããŒãã³ããåãé€ããŠæ°ããã³ã³ããŒãã³ããèšçœ® ããããšã I Impacted ( ã€ã³ãã¯ã ) åæåäžã®ã¢ã¬ã€ãšã¯ãäœææžã¿ã§ãããã®ã®ãåææ§ç¯åŠçã å®äºããŠããªãã¢ã¬ã€ãæããŸãããã¹ãŠã®ã¡ã³ã㌠ãã©ã€ãã ååšãåäœå¯èœãªç¶æ ã§ãã¢ã¬ã€ã«æžã蟌ãŸãããã¹ãŠã®ããŒã¿ ã¯ä¿è·ãããŠããŸããã¢ã¬ã€ãæé©åããã«ã¯ãããªãã¡ã€ãšä¿® æ£ ã®ã¿ã¹ã¯ãå®è¡ããŸãã Initialize ( åæå ) ã³ã³ãããŒã©ããã£ã¹ã¯ã䜿çšã§ããããã«ããããã®ããã£ã¹ ã¯ã®æºåããã»ã¹ããã£ã¹ã¯ãåæåããããšãã³ã³ãããŒã©ã¯ ãã£ã¹ã¯ã« RAID ã·ã°ããã£ãæžã蟌ã¿ãŸãã çšèªé -5 çšèªé Initialized array ( åæåæžã¿ã¢ã¬ã€ ) ããŒã¿ã®èªã¿èŸŒã¿ãšæžã蟌ã¿ã®æºåãæŽã£ãã¢ã¬ã€ãã¢ã¬ã€ã¯ ãBuild ( æ§ç¯ )ããŸãã¯ãClear ( ã¯ãªã¢ )ãã«ãã£ãŠåæåã§ã㟠ãã L Legacy disk ( ã¬ã¬ã·ãŒ ãã£ã¹ã¯ ) ã³ã³ãããŒã©ã«æ¥ç¶ãããæã«ãæå¹ãªããŒãã£ã·ã§ã³ããŒãã« ãå«ãã ãã£ã¹ã¯ã³ã³ãããŒã©ã¯ãã£ã¹ã¯ããã¢ã¬ã€ãšãã£ã¹ã¯ ã®éã«è«ç察ç©çã® 1 察 1 ã®ãããã³ã°ãååšããã¬ã¬ã·ãŒ ã㣠ã¹ã¯ãšããŠç®¡çããŸãã Logical device ( è«çããã€ã¹ ) 1 å°ãŸãã¯è€æ°å°ã®ç©çãã©ã€ãã«å±ããã¹ããŒã¹ããæ§æãã ãŠããªããããªãã¬ãŒãã£ã³ã° ã·ã¹ãã ã§ã¯ 1 å°ã®ãã©ã€ããšã ãŠèŠãªãããããªã¥ãŒã ã Low-level Format ( ããŒã¬ãã« ãã©ãŒããã ) ããŒããã£ã¹ã¯ããããŒã¿ãå®å šã«æ¶å»ããããã«ããã©ã€ãã® ãã¡ãŒã ãŠã§ã¢ã«ãã£ãŠå®è¡ãããããã»ã¹ã M Migration ( ãã€ã°ã¬ãŒã·ã§ã³ ) ãReconfiguration ( åæ§æ )ããåç §ããŠãã ããã Mirrored array/mirroring ( ãã©ãŒãªã³ã°ããã©ãŒ ã¢ã¬ã€ ) ãRAID 1ããåç §ããŠãã ããã Monitoring ( ã¢ãã¿ãªã³ã° ) ã·ã¹ãã ã€ãã³ããåä¿¡ã衚瀺ãããã³ãã®ã³ã°ããããã»ã¹ã O Offline array ( ãªãã©ã€ã³ ã¢ã¬ã€ ) ã¢ã¯ã»ã¹ã§ããªãç¶æ ã®ã¢ã¬ã€ã çšèªé -6 çšèªé Optimal ( æ£åžž ) ã¢ã¬ã€ãå®å šã«çšŒåããç¶æ ããåé·ã¢ã¬ã€ã®å Žåã¯ãã¢ã¬ã€å šäœ ãä¿è·ãããŠããç¶æ ã P Partition ( ããŒãã£ã·ã§ã³ ) ãSegment ( ã»ã°ã¡ã³ã )ããåç §ããŠãã ããã Phantom Object ( ãã¡ã³ãã ãªããžã§ã¯ã ) ã³ã³ãããŒã©ç®¡çãœãããŠã§ã¢ã§æ§æããããšã®ã§ããªãã³ã³ ããŒãã³ãã衚ããªããžã§ã¯ããããšãã°ãæ¬ èœããŠãããã©ã€ ããªã©ã Q Quick Init ( ã¯ã€ãã¯åæå ) Quick Init ãªãã·ã§ã³ã䜿çšããŠåæåãããã¢ã¬ã€ã¯ããã㯠ã°ã©ãŠã³ãã§ã³ã³ãããŒã©ã®ã¢ã¯ãã£ããã£ãå®è¡äžã§ãªããã°ã ãã ã¡ã«äœ¿çšå¯èœã«ãªããŸããã¯ã€ãã¯åæåãããã¢ã¬ã€ã«æž ã蟌ãŸããããŒã¿ã¯ãã¹ãŠä¿è·ãããŸãã R RAID Redundant Array of Independent Disks ( ãŸã㯠Redundant Array of Inexpensive Disks)ã RAID 0 ç°ãªããã£ã¹ã¯äžã«ååšããåããµã€ãºã®è€æ°ã®ã»ã°ã¡ã³ãã§æ§ æãããã ãSingle-level Array ( ã·ã³ã°ã«ã¬ãã« ã¢ã¬ã€ )ããRAID 0 ã§ã¯ãåãã©ã€ãäžã®åããµã€ãºã®ã»ã¯ã·ã§ã³ã«ãããŒã¿ãåç ã«åæ£ (ãStripe ( ã¹ãã©ã€ã )ã) ãããŸããRAID 0 ã¯åé·æ§ãã ããŸããã çšèªé -7 çšèªé RAID 1 2 å°ã®ç°ãªããã©ã€ãäžã«ååšãã 2 ã€ã®çããã»ã°ã¡ã³ãã§æ§ æããããã·ã³ã°ã«ã¬ãã« ã¢ã¬ã€ã2 å°ã®ãã£ã¹ã¯ ãã©ã€ãäžã« åãããŒã¿ãæ ŒçŽããããšã§åé·æ§ãå®çŸããŸãã ãMirrored array/mirroring ( ãã©ãŒãªã³ã°ããã©ãŒ ã¢ã¬ã€ )ããåç § ããŠãã ããã RAID Signature (RAID ã·ã°ãã㣠) RAID ã³ã³ãããŒã©ã䜿çšããããã«äºçŽãããŠããåãã£ã¹ã¯ ã®é åã RAID Volume (RAID ããªã¥ãŒã ) 2 å°ä»¥äžã®åãã¿ã€ãã®ã¢ã¬ã€ãé£çµããŸãã Rebuild ( åæ§ç¯ ) RAID 1 ã«ãããåé·ããŒã¿ã®ããã¯ã°ã©ãŠã³ãåçæã Reconfiguration ( åæ§æ ) ã¢ã¬ã€ã® RAID ã¿ã€ããå¥ã®ã¿ã€ããžæ¡åŒµãŸãã¯ãã€ã°ã¬ãŒã·ã§ ã³ããããã»ã¹ãRAID 0 ã® ãStripe Size ( ã¹ãã©ã€ã ãµã€ãº )ãã 倿Žããããã»ã¹ããŸãã¯ããã€ã¹ã® ãSegment ( ã»ã°ã¡ã³ã )ã ãä»ã®ãã£ã¹ã¯ã«ç§»åããããã»ã¹ã Redundant ( åé·æ§ ) 1 å°ãŸãã¯è€æ°å°ã®ããŒããŠã§ã¢ãæ éããå Žåã§ããéçšãç¶ ç¶ã§ããã¢ã¬ã€ã®æ©èœãRAID 1 ã¯åé·æ§ããããŸãããã©ã€ãã« é害ãçºçããå Žåã¯ãé害ãã©ã€ãã亀æããŠã¢ã¬ã€ãåæ§ç¯ ããããšã§ãåé·ã¢ã¬ã€ã埩å ããŠéåžžã®åäœã«æ»ãããšãã§ã ãŸãã Rescan ( åã¹ãã£ã³ ) ç»é¢ãæŽæ°ããŠãçŸåšäœ¿çšå¯èœãªãã¹ãŠã®ãªãœãŒã¹ã衚瀺ããã ãã»ã¹ã çšèªé -8 çšèªé S Segment ( ã»ã°ã¡ã³ã ) ã¢ã¬ã€ã®äœæã ãFault-tolerant Arrays ( èé害æ©èœãåããã¢ã¬ 〠)ãåŠçã«äŒŽããç©çãã£ã¹ã¯äžã®äºçŽé åãã€ãŸããã¢ã¬ã€ã äœæãããšãèªåçã«ã¹ããŒã¹ãã»ã°ã¡ã³ãã«å€æãããŸããã» ã°ã¡ã³ãã¯åžžã«è«çããã€ã¹äžã«ååšããã»ã°ã¡ã³ãã䜿çšã§ã ãã®ã¯ãäžåºŠã« 1 ã€ã®è«çããã€ã¹ã®ã¿ã§ãã Serial ATA (SATA) ATA ã®åŸç¶ã§ãããŒã¿ã ãã©ã¬ã«ã§ã¯ãªããã·ãªã¢ã«ã€ã³ã¿ãŒ ãã§ãŒã¹ã䜿ã£ãŠè»¢éããŸãã Simple Volume ( ã·ã³ãã« ããªã¥ãŒã ) ããªã¥ãŒã ã¯ãåäžã®ãã£ã¹ã¯ãããªããŸããåäžã®ãã©ã€ãäž ã®åäžãªãŒãžã§ã³ããŸãã¯åããã£ã¹ã¯äžã®é£çµãããè€æ°ã® ãªãŒãžã§ã³ã§æ§æã§ããŸãã Single-level Array ( ã·ã³ã°ã«ã¬ãã« ã¢ã¬ã€ ) 1 ã€ãŸãã¯è€æ°ã®ã»ã°ã¡ã³ãããäœæãããã¢ã¬ã€ããvolume ( ã ãªã¥ãŒã )ãããSpanned Volume ( ã¹ãã³ ããªã¥ãŒã )ãããRAID 0ãã ãRAID 1ããåç §ããŠãã ããã Snapshot ( ã¹ãããã·ã§ãã ) 峿ã«è¡ãããã¢ã¬ã€ã®æ£ç¢ºãªãã€ã³ã ã€ã³ ã¿ã€ã ã³ã㌠( èªã¿ åãå°çš )ã Spanned Volume ( ã¹ãã³ ããªã¥ãŒã ) 2 å°ä»¥äžã®ãã©ã€ãäžã®ã»ã°ã¡ã³ããé£çµãããã®ã Stripe ( ã¹ãã©ã€ã ) ã¢ã¬ã€ã«å±ãããã¹ãŠã®ãã£ã¹ã¯ã«åæ£ããããé£ç¶ããããŒã¿ ã®ã»ãããã¹ãã©ã€ã ã¢ã¬ã€ã§ã¯ãåãã©ã€ãäžã®åããµã€ãºã® ã»ã¯ã·ã§ã³ã«ãããŒã¿ãåçã« ã¹ãã©ã€ãã³ã° ãããŸãã Stripe Size ( ã¹ãã©ã€ã ãµã€ãº ) åã»ã¯ã·ã§ã³ã«å«ãŸããããŒã¿ã®éãã¹ãã©ã€ã ãµã€ãºãšãªã㟠ãã Stripe Size ( ã¹ãã©ã€ã ãµã€ãº ) ãRAID 0ããåç §ããŠãã ããã çšèªé -9 çšèªé T Task ( ã¿ã¹ã¯ ) RAID ã³ã³ãããŒã©äžã®ã¿ã§ãä»ã®ãã¹ãŠã®æäœãšã¯éåæã«å® è¡ãããåŠçãããšãã°ããã£ã¹ã¯ã®åæåãã¢ã¬ã€ã®æ€èšŒãªã©ã ã¿ã¹ã¯ã®äžã«ã¯æéãããããã®ããããŸããã¿ã¹ã¯ã®å®è¡äžã« RAID ã³ã³ãããŒã©ãéäžçãªããŒã¿ I/O ãå®è¡ããå Žåã¯ãªã ããæéãããããŸãã V Verify ( ããªãã¡ã€ ) ãã©ã€ããè«çããã€ã¹ããŸãã¯ããã ã¹ãã¢ãæ£åžžã«åäœã㊠ããããšã確èªããããŒã¬ãã« ãã§ãã¯ãRAID 1 ã§ã¯ãæ€èšŒã¯ äž¡æ¹ã®ã¡ã³ã㌠ã»ã°ã¡ã³ãã®å 容ã«äžè²«æ§ããããã©ããã®ã㌠ã¬ãã« ãã§ãã¯ã§ãããå¿ èŠã«å¿ããŠããã¹ã¿ãŒ ãã©ã€ããæ£ç¢º ã§ããããšãåæãšããŠãšã©ãŒãä¿®æ£ãããŸãããã©ã€ãã«å¯Ÿã ãæ€èšŒã§ã¯ããã©ã€ãå šäœãèªã¿åãå¯èœã§ãããã©ããã®ã㌠ã¬ãã«ãã§ãã¯ãå®è¡ãããŸãã volume ( ããªã¥ãŒã ) ãSimple Volume ( ã·ã³ãã« ããªã¥ãŒã )ãããã³ãSpanned Volume ( ã¹ãã³ ããªã¥ãŒã )ããåç §ããŠãã ããã çšèªé -10 R Adaptec, Inc. 691 South Milpitas Boulevard Milpitas, CA 95035 USA ©2003 Adaptec, Inc. All rights reserved. Adaptec ããã³ã¢ãããã㯠ã®ããŽã¯ãAdaptec Inc. ã®ç»é²åæšã§ããã æ°ã«åœã§ç»é²ãããŠããŸãã Part Number: 513587-06JA, Ver. AB