Download GRAM COMPACT køle
Transcript
F 200/400: Frost should be removed when it is more than 1/2 cm thick. The cabinet should be completely defrosted about twice a year. Procedure: Disconnect power at the mains and place a bowl of hot water in the cabinet. Close the door and wait half an hour. The defrosting might be accelerated by blowing hot air into the cabinet with a hair dryer. The remaining frost can now be wiped off with a warm cloth. Never use a sharp or pointed object, that may damage the freezer. Illumination Applies to models with lamp only (KG 200/400). The lamp can be switched on or off by the switch on the light panel. Replacement of fluorescent tube/starter Switch off power to the cabinet. Press the lower rear edge of the lamp panel and remove the lamp screen. The fluorescent tube/starter can now be turned 90° and replaced by a new one. Use a fluorescent tube type L 15 W / 20 cool white. Use a fluorescent tube starter type 4-80 W, single 220-240 V. Changing from right-hinged door to left-hinged door The door can be changed from righthand-hinged to lefthand-hinged, or vice versa. To do so, proceed as follows: 76-504-0940 16