Download MULTIMETER DIGITAL MULTIMETER DIGITAAL
Transcript
1.Display 3 ½ digit, 7 segment, 15mm high LCD. 2.Function and range switch This switch is used to select the function and desired range as well as to turn on the instrument. To extend the life of its battery, the switch should be in the OFF position when the instrument is not in use. 3.‘Hold’-button by pressing this button the screen will retain the last reading and the symbol H appear in the LCD until you next press the button. 4.10A jack Plug in connector for red (positive) test lead for 10A measurements. 5. Common jack Plug in connector for black (negative) test lead. 6. VΩmA jack Plug in connector for red (positive) test lead for all voltage and resistance and current (except 10A) measurements. Specifications Accuracies are guaranteed for 1 year, 23˚C ± 5˚C, less than 80% RH. DC Voltage Range Resolution Accuracy 200µV 100µV ±0.5% of rdg ±3D 2V 1mV ±0.5% of rdg ±3D 20V 10mV ±0.5% of rdg ±3D 200V 100mV ±0.5% of rdg ±3D 600V 1V ±0.8% of rdg ±5D Overload protection: 250 V rms for level of 200 µV, and 600V DC or rms AC for other levels.