SPECIFICATIONS English Plug Configurations Units are supplied from the factory with an electrical cord and plug installed. Plugs are supplied according to the application. WARNING ELECTRIC SHOCK HAzARD: Plug unit into a properly grounded electrical receptacle of the correct voltage, size, and plug configuration. If plug and receptacle do not match, contact a qualified electrician to determine and install the proper voltage and size electrical receptacle. Electrical Rating Chart Model ITQ-1000-1C ITQ-1750-2C Voltage Hertz 208 60 208–240 † 240 Watts NEMA 6-30P NEMA L6-30P Plug Configurations NOTE: Receptacle not supplied by Hatco. Amps Plug Configuration Shipping Weight* NEma 6-30P, NEma L6-30P 106 lbs. (48 kg) 60 3230–4300 15.5–17.9 NEma 6-30P, NEma L6-30P 60 4960 20.7 NEma 6-30P, NEma L6-30P * Shipping weight includes packaging. 4960 23.8 68 lbs. (31 kg) 106 lbs. (48 kg) † Unit is designed to operate on supply voltages between 208 V and 240 V. Dimensions Model ITQ-1000-1C ITQ-1750-2C Width (A) 17-5/8″ (448 mm) 20″ (508 mm) Depth (B) 28-5/8″ (727 mm) 28-11/16″ (728 mm) Height (C) Footprint Width (D) Footprint Depth (E) Platform Width (F) Conveyor Width (G) Opening Height (H) 16-9/16″ (420 mm) 16-1/4″ (412 mm) 17-3/4″ (450 mm) 16-1/8″ (410 mm) 5-7/16″ (139 mm) 2-1/4" (57 mm) 18″ (457 mm) 13-3/4″ (349 mm) 17-3/4″ (450 mm) 13-3/4″ (349 mm) 9-7/16″ (240 mm) B A H C Specification Label E D Front View Side View G Top View Form No. ITQm-0215 5 F Model ITQ-1000-1C shown. 2″ (51 mm)