Download Contents - MSA World
Transcript
FOR SERVICE TECHNICIAN’S USE ONLY TEST PROCEDURES IMPORTANT: The following procedures may require the use of needle probes to measure voltage. Failure to use needle probes will damage the connectors. To ease the process of measuring voltage and resistance, test points for each pin are accessible through the slots in the plastic beneath each CCU connector. TEST #1: CCU Power Check This test checks for incoming and outgoing power to and from Central Control Unit (CCU). This test assumes that proper voltage is present at the outlet. 1. Unplug washer or disconnect power. 2. Remove top panel to access the machine electronics. 3. Visually check that all connections to the interference filter (IF) are securely connected. See Figure 10, below. 4. Visually check that all connections to the CCU (Figure 11) and Expansion Board (EB) (Figure 15, page 21) are fully inserted. 5. If both visual checks pass, go to step 6. Filter Output - Line (PK) Filter Input - Power Cord Line (BK) 6. Plug in washer or reconnect power. 7. With a voltmeter set to AC, check for line voltage at the input of the interference filter. See Figure 10. If line voltage is present, go to step 8. If line voltage is not present, unplug washer or disconnect power and verify the continuity of the power cord. If it fails the continuity check, replace the power cord. 8. With a voltmeter set to AC, check for line voltage at the output of the interference filter. If line voltage is present, go to step 9. If line voltage is not present, unplug washer or disconnect power and replace the interference filter. 9. With a voltmeter set to AC, check for input line voltage to the CCU across pins 1 and 2 of connector IF2. See Figure 11. If line voltage is present, go to step 10. If line voltage is not present, unplug washer or disconnect power. Check harnesses and connections between the filter and the CCU. Repair as necessary. Filter Output - Neutral (PK) Filter Input - Power Cord Neutral (WT) Figure 10 - Interference Filter (IF) DL3-Door Lock Coil DI6-Detergent Dispenser Motor FM3-Flow Meter DCS3-Door Closed Switch DP2-Drain Pump RP2-Vent Fan VCH7-Hot/Cold Valves VSF2-Steam Valve Locking Tab MS2-MCU Power PS8-Pressure Sensor SET2-Temperature Sensor UIP3-Expansion Brd Power UI7-User Interface MI3-MCU Communications FAC3-Data to Expansion Brd IF2-Interference Filter DLS2-Door Lock Switch HE2-Heater Element HSG2-Expansion Board • = pin-1 Figure 11 - Central Control Unit (CCU) DO NOT REMOVE OR DESTROY PAGE 13