Download Owner`s Manual AIR COMPRESSOR
Transcript
For replacement parts contact: www.allpartsinc.com 1-877-475-5660 TROUBLESHOOTING Risk of Unsafer Operation. Performing repairs may expose voltage sources, moving parts, or compressed air sources. Personal injury may occur. Before servicing: Unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool. PROBLEM Excessive tank pressure - safety valve pops off. CAUSE Pressure switch does not shut off motor when compressor reaches "cut-out" pressure. Pressure switch "cut-out" too high. CORRECTION Move On/Auto/Off lever to the "OFF" position, if the unit does not shut off contact a Trained Service Technician. Contact a Trained Service Technician. Air leaks at fittings. Tube fittings are not tight enough. Tighten fittings where air can be heard escaping. Check fittings with soapy water solution. Do Not Overtighten. Air leaks at or inside check valve. Check valve seat damaged. A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off. Replace check valve. Refer to the "To Replace or Clean Check Valve" in the Service and Adjustment section. Air leaks at pressure switch release valve. Defective pressure switch release valve. Contact a Trained Service Technician. Air leaks in air tank or at air tank welds. Defective air tank. Air tank must be replaced. Do not repair the leak. Risk of Bursting. Do not drill into, weld or otherwise modify air tank or it will weaken. The tank can rupture or explode. Air leaks between head and valve plate. Leaking seal. Contact a Trained Service Technician. A17893 For replacement parts contact: 20- ENG www.allpartsinc.com 1-877-475-5660