2. Partially armed syst em: in this c ondition the c ontrol panel has a different functioning accordi ng to the s ystem c onfiguration (B1 – B2) and the
consequent programming carried out during installation. Detec tors with entry delay will start the alar m after the programmed delay: during this time
you will hear a s ound confirmati on from the control panel (continuous BEEP). Possible alar ms in this ti me l aps will not be taken into c onsideration if the
system is disar med.
2.1 Tr aditional configuration (paragr aph B1). In this condition you c an have:
• General alarm for any alarm detec ted by a sens or in an armed group: all sirens sound for 3 mi nutes and the voc al mess age/SMS ar e sent to the
numbers c ombined with message 1. All further warnings/operations , for eseen in case of disar med s ystem, remain acti ve.
2.2 Configuration with anti-robber y extern al pre- alarm (paragr aph B2). In this condition you c an have:
• Pre-alarm anti-robbery for any alarm detec ted by an outdoor sens or (A group): the control panel buzz er sounds for 3 minutes, with paus es when
calls start to the numbers combi ned with message 1. The sirens 5430 and the status signalling devices 5026B sound with continuous low-intensity
BEEEP and flash for 3 mi nutes. T he vocal keypads 5429V pronounce the mess age recorded for external alar m.
• General alarm for any alar m detected by a sens or in an ar med group (B or C): all sirens sound for 3 mi nutes and the vocal message/SMS are
sent to the numbers combi ned with mess age 1. All further warnings/operations, fores een in c ase of disarmed s ys tem, remai n acti ve.
3. Totally armed system: in this conditi on the control panel has a different functioning accor ding to the s ystem c onfiguration (B1 – B2) and the
consequent programming carried out during install ation. Detectors with entr y delay will start the al arm after the programmed delay: during this ti me you
will hear a s ound c onfirmation from the control panel (conti nuous BEEP).
3.1 Tr aditional configuration (paragr aph B1). In this condition you c an have:
• General alarm for any alar m detected by a sens or in an armed group: all sirens sound for 3 minutes and the vocal message/SMS are sent to the
numbers c ombined with message 1.
• 24-hour tamper: in c ase of tamper of c ontrol panel, detec tors, sirens and bidirec tional keypads, all sirens sound and vocal message/SMS are s ent
to the numbers combined with mess age 2.
• Panic: through remote contr ols and keypads, all the sirens sound for 3 minutes and vocal mess age/SMS are sent to the numbers combined with
mess age 3.
• Anomal y alar m (anti-scanner – radio nois es): in this case the control panel built-in siren and possible further hardwired sirens sound for 30
seconds.
All further warnings/operati ons, fores een in c ase of disarmed s ys tem, remai n ac tive.
3.2 Configuration with anti-robber y external warn ing (paragr aph B2). In this c ondition it is nec essar y to c onsider if it is conveni ent to full y arm the
system, bec aus e in this way the anti-robbery protection would be acti ve and would signal possibl e intrusion attempts i n the protected external area
with short and c onti nuous BEP. The end us er should consider if, in his cas e, nobody has reall y no reas on to enter these areas: if it is not the case, we
suggest to arm onl y the “anti-intrusion” groups (B+C).
4. Self-exclusion of det ectors and sirens
After 3 detected alar ms, the relevant detec tor excludes its elf automaticall y ( alarm counting func tion): obviousl y the other det ectors remain active.
Some models of sirens can also have this kind of alarm counting, so that they limit the disturb of public peac e in cas e of failure: please c heck this
aspec t on the rel evant siren handbook.
G) EVENTS STORING AND CONTROL
The control panel can store up to 200 events occurred (armi ng, disarmi ng, various alar ms), displ aying the date, the ti me and the r elevant peripheral
device. The events always queue up, i.e, the 201st event c anc els the first one and s o on. T o see how to read the events memor y s ee paragraph C5.
Because of the display small size, i n some cases you will see onl y abbr eviations, to be interpreted as follows (example):
a) call with vocal message to wards Mar co
b) call for pc r emote m anagem ent towards the installer ’s T eleservice
control panel dis play
control panel dis play
INSTALLER OK
Abbrevi ations :
← : outgoing call
OK : successful c all
c) system arming - user Mar co
→ : incomi ng call
OC : bus y
V : vocal mess age S : SMS
KO : no succ essful call
d) tamper alarm - door 1
control panel dis play
control panel display
ARMING
TAMPER
MARCO
ABBREVIATIONS
ARM : contr ol panel arming
D.OPEN : open door
SUPERV : super vision alar m
REMOTE : remote operation via telephone
INSTALL : entr y in the installer menu
USER : entr y in the us er menu
D : digital protoc ol
NO : no ans wer
ARM /A/B/C : group arming
TAMPER : tamper
SCAN : RF noise alarm
LABEL : peripher al devic e name
REM : remote c ontrol
DET : detector
DOOR 1
DISARM : disarming
ALARM : alarm
BATT :
low batter y
EXCLUD : deac tivated
COD : keypad code
EXT AL : external alarm
PROGR : programming
DELETE : erasing
INCLUD : activated
W IR: hardwired input
NO PSTN LINE: PSTN line failure
MAINS F AILURE: 220V failure
NO GSM NETW ORK: GSM network failure
CHANGE NUM. : number in phone book c hanged via SMS
GSM CHECK: automatic GSM s witchi ng off and on
SILENTRON - ITALIA
COPYRIGHT SIL ENTRON 5404T BD C 061025GM