Download ALTI-AQUA
Transcript
ENGLISH 7. INSTALLATION AND ELECTRICAL CONNECTION 7.4 Electrical connection DANGER! Danger of death! Electrical connection must be carried out by an electrician authorised by the local electricity supply company and in accordance with the applicable local regulations. 7.1 Installation site Install the pressure boosting system in an easily accessible, normally ventilated room protected against freezing. Make sure that the pressure boosting system can be transported through the door of the room. When carrying out electrical connection, the installation and operating instructions and the wiring diagrams provided must be followed. The following general instructions apply: Provide enough space for maintenance work. The system should be freely accessible from at least two sides. 7.2 •The current type and the mains voltage must comply with the details on the rating plate and terminal diagram of the switchgear. Installation Position the system on a smooth, flat bearing surface or on a concrete pedestal which is anchored to the bearing surface below. Provide insulation material (made of cork or reinforced rubber) between the pedestal and the bearing surface to prevent the transmission of flow noise. •For safety reasons, the pressure boosting system must be properly earthed (meaning earthed in accordance with the local regulations and conditions); the terminals provided for this purpose are marked accordingly (see also the terminal diagram). 7.3 Hydraulic connection Connecting cable CAUTION! Risk of damage to the product! Comply with the requirements of the water supply company and the applicable local regulations. The electrical connecting cable must be properly dimensioned according to the total power of the pressure boosting system (see rating plate). •The suction/pressure pipes can be connected either on the right or the left; seal off the unused openings with threaded caps. Do not connect the switchgear to any voltage other than that specified in the instructions (see 5.2 Technical data). NOTE: There is a wiring diagram with detailed information provided in the switchgear and in Fig. 9a / 9b. •Fit valves in the pipes so that the system can be isolated from the mains if necessary. CAUTION! Risk of damage to the product! Do not forget to connect the earth terminal! •The system must always have at least one diaphragm pressure vessel with a capacity of 18 or 24 l installed on the pressure pipe (see Fig. 1); if its capacity is greater, the vessel should be positioned next to the system. Dry-running protection An On-Off input (250 V 2 A) (Fig. 5, No.1 and 2) is provided to protect the pressure boosting system from low water; a pressure switch (normally open contact) or float switch needs to be connected to this input for this purpose. •The existing pipes on site must be connected to the system without any tension whatsoever. We recommend using expansion joints or flexible connection hoses for this purpose, in order to prevent tension in rigid connections and the transmission of vibrations from the system to the building. CAUTION! Risk of damage to the product! Do not apply any additional external voltage to the terminals! Direct connection to municipal water supply network Check whether the system installed at the site is able to withstand the maximum pressure of the pump at zero flow plus the pressure of the municipal water supply network. If this is not the case, install a pressure reducer at the output of the pressure boosting system. We strongly recommend fitting a pressure reducer and a regulating valve in the inlet pipe of the pressure boosting system in order to prevent pressure fluctuations at the system's inlet. Intake from break tank Check whether the system installed at the site is able to withstand the maximum pressure of the pump at zero flow plus the pressure of the break tank. If this is not the case, install a pressure reducer at the output of the pressure boosting system. Suction operation from break tank Make sure that the friction loss in the suction line is not greater than the suction capacity of the pumps (check the NPSH). We recommend installing a foot valve with strainer with a pipe having a diameter which is at least the nominal diameter of the suction line or one size larger. 19