Download S-7200B - vnz rutha

Transcript
3. FUNCTION SETTINGS (OPERATION PANEL)
Function No. 61 − 68
No.
Initial value
Setting range
61
0
0–1
62
(NOTE 18)
0
0–1
63
0
0–1
64
0
0–2
65
(NOTE 18)
150 (ms)
10 – 500 (ms)
66
(NOTE 18)
0
0–1
67
(NOTE 18)
0 (degrees)
-20 – 20
(degrees)
68
(NOTE 20)
0
0–1
Setting details
Highest needle position stop operation
0: Not used
1: Used
Thread wiping operation during highest needle position stop operation
0: Thread wiping occurs after needle stops in highest position
1: Thread wiping occurs after thread trimming, and then needle bar is raised
Thread trimming timer operation
0: Not used (Thread trimming is off when needle bar is stopped at the up
position)
1: Used (Time is set using Function No. 73)
0: Standard
1: Not used
2: Twin needle lock stitcher (T-8422A-[][]3)
[Do not change this setting]
Delay time until reverse operation starts during highest needle position stop
operation
Presser foot lift timing during highest needle position stop operation
0: Presser foot is raised after needle bar is raised
1: Presser foot is raised before needle bar lift operation starts (See NOTE
19)
Highest needle position stop position setting
Becomes lower
Becomes higher
2248M
Seam matching function during automatic backtacking
0: Operation does not stop when switching cloth feed direction
1: Operation momentarily stops when switching cloth feed direction
(NOTE 18) Setting is enabled when Function No. 61 is set to “1”.
(NOTE 19) Operation is disabled when Function No. 62 is set to “1”. Presser foot is raised after needle bar is raised.
(NOTE 20) Used when you would like to match the seam accurately during automatic backtacking. Use Function No. 78 to
set the stop position and Function No. 79 to change the time before restarting.
11
S-7200B