CHAPTER 3 MAINTENANCE PROCEDURES TABLE 3-1. MOUNTING BOLT TORQUE SETTINGS MODEL TORQUE SETTING R31P(E)1502 RC31P1502 6N to 8N R31P(E)3 RC31P3 6N to 8N R31P(E)6 RC31P6 6N to 8N R31P(E)15 RC31P15 6N to 8N R31P(E)30 RC31P30 6N to 8N 6. Set Overload Stops as shown in Section 3.6. 3.6 Setting the Overload Stops The Overload Stop gaps must be checked and reset if the Load Cell is replaced. This procedure requires test masses equal to the scale’s capacity. (See Table 3-2.) There are four Overload Stop Bolts. (See Figure 3-5.) Adjust the Overload Stops, per Table 3-2: 1. Adjust the Overload Stop Bolt so that the gap between the Load Cell Frame and the Overload Stop Nut is equal to the specification in Table 3-2. (The gap can be tested by applying 100% load, one corner at a time, at each corner stop. If the gap is right, the Load Cell Frame will just touch the Overload Overload Stop Nut.) Stops Note: Be careful not to overload the Load Cell, which would damage it. Figure 3-5. Overload Stops. 2. Repeat this for all four corners. 3. Test the scale to see if full capacity can be achieved. Ranger™ (Count) 3000 Series Service Manual 3-5 Ohaus Corporation www.ohaus.com