Download Service Manual
Transcript
SERVICE MGII and MG2T GAS FRYER WARNING! SHUT OFF APPLIANCE AND DISCONNECT ALL POWER CONNECTIONS PRIOR TO STARTING ANY SERVICE WORK 6. Attach flue to flue brackets using 5/16” hex bit and 3/8” socket or box wrench to tighten screws and nuts. 7. Clean old gasket material from burner rack face. Install new burner gasket onto burner rack. Spray glue may be used to hold gasket in place. 8. Install burner rack onto tank front. Secure burner rack to tank using 6 screws and a 5/16” hex bit. On full tanks, leave out 2 screws in lower right front of rack. On split tanks, leave out 2 screws in lower center of rack. (These screws will be installed when the high limit bracket is installed.) 9. Apply pipe thread compound or Teflon tape onto tank drain nipple(s). 10. Install drain valve(s) onto tank nipple(s) using pipe wrench. On full tanks, tighten until drain valve stem is facing right. On split tanks, drain valve stems should face each other. 11. Insert probe(s) from top of tank through fitting(s) in tank bottom. 12. On split tanks, install probe clamp using Phillips screwdriver. L22-236 Rev. 2 (06/11) 31