Download Service Manual, Rev. A

Transcript
Kodak DryView 8100 Laser Imager Service Manual
Section 7 – Troubleshooting
7-3
1999 Rev. A
7-2.
Sensor Functions
The system includes three types of sensors: a single flag-type and two kinds of U-type optical switches.
(Actually, all the U-type sensors are alike but one, Optics Home Sensor S7, which is screw-mounted.)
Functions of the sensors are described in Table 7-2. See the following pages for testing procedures.
Table 7-2. Sensor Functions
Ref Des
Sensor Description
Assembly
Type
Sensor Output
S1
Cartridge Present
Rollback
Flag
S2
Rollback Home
Rollback
U–type
Low (OFF) when lid is closed
S3
Pickup Position
Pickup
U–type
High (ON) with pickup assy in feed
position. Low when pickup assy is at top.
S4
Film Surface
Pickup
Flag
High (ON) when flag contacts film
S5
Film Out
Pickup
Flag
Low (OFF) when film is out
S6
Platen Film
Imaging
Flag
High (ON) when film contacts flag
S7*
Optics Home
Imaging
U–type
Low (OFF) when scanner is home
S8
Vertical Transport
Vert. Trans.
Flag
High (ON) when flag contacts flag
S9
Densitometer/Exit
Densitometer
Flag
High (ON) when film contacts flag
S10
Cups Engaged
Pickup
U–type
Low (OFF) when cups are squashed
S11
Feed Roller Open
Feed Roller
U–type
Low (OFF) when rollers are open
S12
Elevator Home
Elevator
U–type
Low (OFF) when elevator is down/home
Attenuator Home
Scanner
Not observable (in optics module)
Shaft Index
Scanner
Not observable (in optics module)
High (ON) when cartridge is loaded
*Optics Home Sensor S7 is the only U-type sensor that is screw-mounted. Note in Figure 7-1 that S7
has a different pinout from the other sensors.
Note
A blocked sensor = low = OFF (not conducting)
Figure 7-1. Sensor Types