5. Trouble Shooting
Display
code
Title
Cause of error
Check point & Normal condition
67
Outdoor fan
lock
• Outdoor fan is not operating
• Check the fan condition.
• Check the fan connector
• Check the fan control part of the INVERTER PCB
n Error Diagnosis and Countermeasure Flow Chart
CH67(Outdoor fan lock) occurrence
Is fan connector condition right ?
No
Do right fan connector condition
Yes
No
Is Fan motor nomal?
Change abnomal motor
Yes
Replace inverter PCB assembly
<INVERTER PCB connection>
<fan motor middle connection>
<FAN Motor Connection check>
Check Point
1.Check error code again, after replacing the abnormal part (Fan Motor or PCB) first.
Copyright ©2012 LG Electronics. Inc. All right reserved.
Only for training and service purposes
- 137 -