SEBU8417-01 171 Maintenance Section Engine Oil Level - Check NOTICE Caterpillar oil filters are built to Caterpillar specifications. Use of an oil filter not recommended by Caterpillar could result in severe engine damage to the engine bearings, crankshaft, etc., as a result of the larger waste particles from unfiltered oil entering the engine lubricating system. Only use oil filters recommended by Caterpillar. 7. In order to install the filter elements, align the collapsible package to the opening of each housing. Press each filter element upward into the housing until the element seats. Follow the instructions on the package of the filter element. Note: Do not touch the filter elements. Do not allow contaminants to contact the filter elements. 8. Install the housing covers. 9. Start the engine and operate the engine at an idle for five minutes. Inspect the oil filters for leaks. Make any necessary repairs. 10. Check the engine oil level. If necessary, add oil. For the proper procedure, refer to Operation and Maintenance Manual, “Engine Oil Level - Check”. i03712140 Engine Oil Level - Check SMCS Code: 1302; 1318; 1326 NOTICE Do not under fill or overfill engine crankcase with oil. Either condition can cause engine damage. 1. Prepare the machine for maintenance. Refer to Operation and Maintenance Manual, “Prepare the Machine for Maintenance”. Illustration 197 g01998853