Download AC Theory - David Knight. Radio, electrical and electronic articles.

Transcript
87
This process can be extended to find the magnitude of a vector in an arbitrary number of
dimensions (we can't make perspective drawings in more than three dimensions, but there is no
restriction on the number of dimensions that a vector can have). Hence:
U = √( U1² + U2² + U3² + . . . . + Un² )
Now note that this formula says: "to find the overall uncertainty; calculate the sum of the squares of
the uncertainty contributions and take the square root." The uncertainty contributions are not the
same as the uncertainties in the measurements made.
Imagine that an unknown quantity x is given by a formula f, which is a mathematical function
involving measurable quantities (variables) m1, m2, m3, etc. We can express this situation by
writing:
x = f(m1, m2, m3, ...)
and we can determine x by plugging m1, m2, m3, etc. into the formula. We can also determine the
uncertainty contribution due to any one of the variables by changing it and noting the change which
occurs in x. The obvious amount by which to change the variable is its standard deviation, hence:
x+σx1 = f(m1+σ1, m2, m3, ...)
Here we have assumed that a positive change in m1 will cause a positive change in x. This might
not be the case, but since we intend to add the contributions from changes in each of the variables as
orthogonal vectors, it makes no difference either way. Now, restoring m1 to its original value we
determine the uncertainty contribution due to m2.
x+σx2 = f(m1, m2+σ2, m3, ...)
and so on. If we work through all of the variables in this way and determine their error
contributions, we can obtain an estimate of the standard deviation of x by summing the squares of
the contributions and taking the square root:
σ = √( σx1² + σx2² + σx3² + . . . . + σxn² )
Note that there are a number of assumptions inherent in this procedure: firstly, as discussed before,
that the uncertainties are uncorrelated; and secondly that we have assumed that the function f is
linear for changes in any of the variables. The latter condition is normally true to a good
approximation for small changes, and the effect of any non-linearity is mitigated by the fact that the
object of the exercise is to obtain an estimate.
Example:
The output resistance Rg of an RF amplifier was determined by loading the output with two
different resistances and noting the change in the output voltage with all other conditions held
constant. The applicable formula is equation (38.1):
Rg = R1 R2 (NV - 1) / (R2 - R1 NV)
Where NV is the ratio of the output voltages:
NV = V2/V1
The voltage measurements were made using an oscilloscope, and it was considered that each
measurement had an uncertainty of about 2%. It was also considered that these uncertainties were
uncorrelated because they were incurred by different operations; one operation being to set the
transmitter carrier level and oscilloscope Y-shift until the waveform just touched the top and bottom
of the measuring graticule with the higher value resistor connected, the other being to read the
height on the graticule with the lower value resistor connected. The overall uncertainty of the
voltage ratio measurement was therefore taken to be the square root of the sum of the squares of the
two voltage measurements; i.e., √(2²+2²)=2.8%, which was rounded to 3% in view of the
approximate nature of the estimate. The actual voltage ratio was 1.364, and 3% of 1.364 is 0.04.
Hence:
NV = 1.364 ±0.04
The resistances were measured using a multimeter known to read correctly within ±0.1Ω against a
standard resistance of 100.0Ω. The stated accuracy of the instrument was ±0.8% ±1 digit. The