87 This process can be extended to find the magnitude of a vector in an arbitrary number of dimensions (we can't make perspective drawings in more than three dimensions, but there is no restriction on the number of dimensions that a vector can have). Hence: U = √( U1² + U2² + U3² + . . . . + Un² ) Now note that this formula says: "to find the overall uncertainty; calculate the sum of the squares of the uncertainty contributions and take the square root." The uncertainty contributions are not the same as the uncertainties in the measurements made. Imagine that an unknown quantity x is given by a formula f, which is a mathematical function involving measurable quantities (variables) m1, m2, m3, etc. We can express this situation by writing: x = f(m1, m2, m3, ...) and we can determine x by plugging m1, m2, m3, etc. into the formula. We can also determine the uncertainty contribution due to any one of the variables by changing it and noting the change which occurs in x. The obvious amount by which to change the variable is its standard deviation, hence: x+σx1 = f(m1+σ1, m2, m3, ...) Here we have assumed that a positive change in m1 will cause a positive change in x. This might not be the case, but since we intend to add the contributions from changes in each of the variables as orthogonal vectors, it makes no difference either way. Now, restoring m1 to its original value we determine the uncertainty contribution due to m2. x+σx2 = f(m1, m2+σ2, m3, ...) and so on. If we work through all of the variables in this way and determine their error contributions, we can obtain an estimate of the standard deviation of x by summing the squares of the contributions and taking the square root: σ = √( σx1² + σx2² + σx3² + . . . . + σxn² ) Note that there are a number of assumptions inherent in this procedure: firstly, as discussed before, that the uncertainties are uncorrelated; and secondly that we have assumed that the function f is linear for changes in any of the variables. The latter condition is normally true to a good approximation for small changes, and the effect of any non-linearity is mitigated by the fact that the object of the exercise is to obtain an estimate. Example: The output resistance Rg of an RF amplifier was determined by loading the output with two different resistances and noting the change in the output voltage with all other conditions held constant. The applicable formula is equation (38.1): Rg = R1 R2 (NV - 1) / (R2 - R1 NV) Where NV is the ratio of the output voltages: NV = V2/V1 The voltage measurements were made using an oscilloscope, and it was considered that each measurement had an uncertainty of about 2%. It was also considered that these uncertainties were uncorrelated because they were incurred by different operations; one operation being to set the transmitter carrier level and oscilloscope Y-shift until the waveform just touched the top and bottom of the measuring graticule with the higher value resistor connected, the other being to read the height on the graticule with the lower value resistor connected. The overall uncertainty of the voltage ratio measurement was therefore taken to be the square root of the sum of the squares of the two voltage measurements; i.e., √(2²+2²)=2.8%, which was rounded to 3% in view of the approximate nature of the estimate. The actual voltage ratio was 1.364, and 3% of 1.364 is 0.04. Hence: NV = 1.364 ±0.04 The resistances were measured using a multimeter known to read correctly within ±0.1Ω against a standard resistance of 100.0Ω. The stated accuracy of the instrument was ±0.8% ±1 digit. The