Evolver Solventborne Robotic Atomizers - Maintenance
TROUBLESHOOTING GUIDE
General Problem
Possible Causes
Corrective Action
Fluid Does Not
Turn On
1. Trigger pilot regulator has
not been set to a minimum
of 70 psig
1. Increase to 70 psig minimum.
2. The green air tube possibly
left disconnected during reassembly
2. Reconnect tubing.
3. Green tube leading from
the source to the gun
mounting plate is pinched or
broken
3. Check the tubing for kinks or damage. Replace if worn or damaged.
4. Piston seal within the gun
spray head is not in place
or there is an extremely
tight fit between the seal
and the cylinder wall
4a. Make sure that the seal is in the proper position and/or lubricate with a small amount of
petroleum jelly.
4b. O-rings left out of small Ø tie rods.
4c. O-ring missing between mounting block and
upper manifold.
4d. O-ring missing between mounting block and
replaceable head.
No Fan or
Atomization Air
Pressure At the Air
Cap
1. Low trigger pilot air pressure (70 psi min. required)
1. Increase pressure.
2. Air tubes 79134-00 are not
installed properly.
2. Reinstall and tighten as required.
3. Black or natural 3/8" OD
tube is cut or pinched
3. Examine, repair as required.
Note: A test station to bench test the applicator off-line will speed the Troubleshooting process.