Download SMQ Service Manual
Transcript
SERVICE ADJUSTING THE FREQUENCY (RATE) Knowledge of the procedure listed below will reduce service time. 1. Establish customer's reason for return of watch. 2. Visually inspect watch for damage. 3. Check the battery for correct voltage, position (+ or -) and number. Use a metal blade, inbedded in a nonconductive material, to turn the trimmer in the appropriate direction (+ or -). On the average, the maximum rate change is approximately 8 seconds per day. Avoid excessive downward pressure on the trimmer. A frequency reading that will not change drastically when the trimmer is turned 3600 indicates a faulty trimmer. Replace trimmer if possible, P.C. Board if necessary. A frequency reading that cannot be regulated to within tolerance (trimmer OK) indicates a faulty Quartz and must be replaced. Replace Quartz Crystal if possible, P.C. Board if necessary. A Quartz Crystal that is vibrating and produces a reading on the frequency counter does not indicate that the complete electronic unit is functioning. There are basically 2 halves to a P.C. Board. One half drives the Quartz. The other half contains the circuit which reduces the Quartz vibration from 32,768 Hz per second down to 60, 30, 20, 6, 2, etc., pulse signals per minute to the rotor (motor). Therefore; 1) No frequency reading indicates possible faulty Quartz, electronic circuit, or dead battery. 2) Good frequency reading but no impulse signal on meter indicates possible loose contact screw, open coil, or faulty P.C. Board. (See pages 4 and 5.) CLEANING It is not necessary to clean an SMQ movement periodically. Clean only those areas that require cleaning. The following components should not be subject to heat or harsh cleaning solvents: The Electronic Circuit, Coil Winding, Stepping Rotor, Quartz Crystal cannister, stator or any of the plastic parts. The proper cleaning solutions and method of cleaning will be indicated within the individual service manual. The rotor pivots and pinion can be cleaned with "One Dip", soft pith wood, or "One Touch". DO NOT PUT IT IN CLEANING SOLUTIONS (some magnets are cemented to an arbor and may separate if subjected to strong solution). LUBRICATION Unlike mainspring driven watches which exert extreme pressure on the wheel pivots and bearings, subjecting them to a high degree of wear, the SMQ design is such that it reduces wear drastically. The wheels of an SMQ are "Free Floating", with a minimum of pressure. It is, therefore, extremely important that the correct lubricant, and amount of lubrication used, be carefully controlled. Avoid heavy lubricants and excess application in the gear and dial train area! ! ! Do not lubricate unless recommended in individual Service Bulletin. HELPFUL HINTS ELECTRONIC CIRCUIT Use a tweezer to grip the Printed Circuit Board not covered by the printed pattern. Do not touch circuit board with fingers, or scratch the printed circuit. Note: Check before removing P.C. Board. Some P.C. Boards have the coil attached and both the board and coil retaining screws must be removed betore disassembling P.C. Board. Fig. 6 ~iJ--LUBRICATE COIL ASSEMBLY Use a tweezer to grasp the coil core at the bare hole end and not the end containing the connections to the printed circuit. IMPORTANT , ,I I. Lubricate the slip area between the arms of the driving wheel and the cannon pinion as shown here. STEPPING ROTOR Handle rotor by its pinion and not the magnet. Do not put in cleaning solutions other than those recommended in service manual. (Some magnets are cemented to arbor and may separate if subjected to strong solutions.) Either lack of lubrication or foreign matter between the cannon pinion and the center wheel post, or the cannon pinion and the driver wheel, can cause the pinion to bind, creating damage to the minute wheel, hour wheel, and minute post. Check the Service Bulletin for proper lubrication. CHECKING THE FREQUENCY TO OPEN CASE: Use a piece of plastic sheet placed between the case opener and case to prevent damage to the case. REMOVING HANDS: (RATE) On some models, the cannon pinion may lift during hand removal. Make certain the cannon pinion is lowered before advancing to the next operation. If the cannon pinion is not lowered, damage may occur to the dial train during attempts at setting the watch. Place the watch on a frequency counter pick-up. The crystal frequency should be "0" + or - 0.4 seconds a day. Trimmer allows watch to be regulated accordingly. 7